Reginald O Chinweze, Neal C Weldon, Matthew A Tao, Melissa N Manzer, Elizabeth A Wellsandt
{"title":"Reliability of Semi-Automated Volumetric Quantification of Knee Effusion Using MRI After Acl Injury.","authors":"Reginald O Chinweze, Neal C Weldon, Matthew A Tao, Melissa N Manzer, Elizabeth A Wellsandt","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Effusion is a frequent finding after anterior cruciate ligament (ACL) injury and reconstruction, but the reliability of its quantification on routine [non-contrast] magnetic resonance imaging (MRI) is not established. This study sought to evaluate the intra-rater and inter-rater reliability of volumetric quantitative measurements (VQM) of knee effusion volumes (EV) using axial proton density-weighted, fat-suppressed (PD-FS) sequences after ACL injury and reconstruction.</p><p><strong>Methods: </strong>Twenty deidentified MRIs (10 ACL-injured knees and 10 uninjured knees) were randomly selected from a prospective observational cohort of participants aged 15-35 years. Two independent raters analyzed EV using a custom MATLAB protocol. Intra- and inter-rater reliability was assessed using intraclass correlation coefficients (ICC<sub>3,1</sub>) with minimal detectable changes calculated. Measurement agreement was assessed using Bland-Altman plots.</p><p><strong>Results: </strong>Mean EV were higher in the injured compared to uninjured knees (11.88±8.14 mL vs 2.03±0.76 mL). Volumetric effusion measurements demonstrated excellent intra-rater (ICC<sub>3,1</sub>=0.993, 95% CI: 0.981-0.997, p<0.001) and inter-rater reliability (ICC<sub>3,1</sub>=0.974, 95% CI: 0.907-0.991, p<0.001). The minimal detectable change was 0.145 mL for intra-rater measurements and 0.504 mL for inter-rater measurements. Bland-Altman plots revealed no systematic bias between raters, although variability increased with larger volumes (>8 mL).</p><p><strong>Conclusion: </strong>VQM using standard axial PD-FS MRI sequences demonstrate excellent reliability across raters. Restricting segmentation to the anterior compartment aligns with clinical assessment (e.g., sweep tests), though it does not capture whole-joint eflusion. This semi-automated approach may provide a relevant biomarker for monitoring EV in ACL research and rehabilitation trials.</p><p><strong>Level of evidence: </strong>III.</p>","PeriodicalId":94233,"journal":{"name":"The Iowa orthopaedic journal","volume":"46 1","pages":"213-221"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13389605/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Iowa orthopaedic journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Effusion is a frequent finding after anterior cruciate ligament (ACL) injury and reconstruction, but the reliability of its quantification on routine [non-contrast] magnetic resonance imaging (MRI) is not established. This study sought to evaluate the intra-rater and inter-rater reliability of volumetric quantitative measurements (VQM) of knee effusion volumes (EV) using axial proton density-weighted, fat-suppressed (PD-FS) sequences after ACL injury and reconstruction.
Methods: Twenty deidentified MRIs (10 ACL-injured knees and 10 uninjured knees) were randomly selected from a prospective observational cohort of participants aged 15-35 years. Two independent raters analyzed EV using a custom MATLAB protocol. Intra- and inter-rater reliability was assessed using intraclass correlation coefficients (ICC3,1) with minimal detectable changes calculated. Measurement agreement was assessed using Bland-Altman plots.
Results: Mean EV were higher in the injured compared to uninjured knees (11.88±8.14 mL vs 2.03±0.76 mL). Volumetric effusion measurements demonstrated excellent intra-rater (ICC3,1=0.993, 95% CI: 0.981-0.997, p<0.001) and inter-rater reliability (ICC3,1=0.974, 95% CI: 0.907-0.991, p<0.001). The minimal detectable change was 0.145 mL for intra-rater measurements and 0.504 mL for inter-rater measurements. Bland-Altman plots revealed no systematic bias between raters, although variability increased with larger volumes (>8 mL).
Conclusion: VQM using standard axial PD-FS MRI sequences demonstrate excellent reliability across raters. Restricting segmentation to the anterior compartment aligns with clinical assessment (e.g., sweep tests), though it does not capture whole-joint eflusion. This semi-automated approach may provide a relevant biomarker for monitoring EV in ACL research and rehabilitation trials.