A systematic review and meta-analysis comparing the clinical outcomes of the Watchman FLX versus Watchman 2.5 device for transcatheter left atrial appendage occlusion in patients with atrial fibrillation.

Q3 Medicine
Meerab Ali Khan, Ayesha Muhammad, Hunain Shahbaz, Abbas Khan, Khawaja Arham Jawaid, Talha Riaz, Khizran Attaullah, Airij Noor, Saeeda Zahid, Mariam Azam Warya, Usama Khan, Mazhar Ali, Saja Mohammed Taher Al-Zamili, Bilal Aslam, Ayleen Umar, Abdullah Abdullah, Zaryab Bacha
{"title":"A systematic review and meta-analysis comparing the clinical outcomes of the Watchman FLX versus Watchman 2.5 device for transcatheter left atrial appendage occlusion in patients with atrial fibrillation.","authors":"Meerab Ali Khan, Ayesha Muhammad, Hunain Shahbaz, Abbas Khan, Khawaja Arham Jawaid, Talha Riaz, Khizran Attaullah, Airij Noor, Saeeda Zahid, Mariam Azam Warya, Usama Khan, Mazhar Ali, Saja Mohammed Taher Al-Zamili, Bilal Aslam, Ayleen Umar, Abdullah Abdullah, Zaryab Bacha","doi":"10.1097/HPC.0000000000000434","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter left atrial appendage occlusion (LAAO) prevents cardioembolic stroke in patients with non-valvular atrial fibrillation who cannot tolerate long term anticoagulation. Whether the second-generation Watchman FLX confers superior clinical outcomes over the first-generation Watchman 2.5 remains incompletely characterized.</p><p><strong>Methods: </strong>We performed a PRISMA 2020-compliant systematic review and meta-analysis of studies comparing Watchman FLX with Watchman 2.5. Three electronic databases were searched through April 2026. Pooled risk ratios (RRs) and mean differences (MDs) with 95% confidence intervals (CIs) were derived using DerSimonian-Laird random-effects models. Nine prespecified outcomes were analyzed: procedural success, device-related embolism, device-related thrombosis (DRT), major bleeding, pericardial effusion, all-cause mortality, any stroke, ischemic stroke, and length of hospital stay (LOHS).</p><p><strong>Results: </strong>Seven observational cohort studies enrolling 131,728 patients (Watchman FLX: n = 54,023; Watchman 2.5: n = 77,705) were included. All studies received Newcastle-Ottawa Scale scores of 8-9 (high quality). The Watchman FLX demonstrated significantly higher procedural success (RR 1.02 [1.02-1.02]; p < 0.00001) and significant reductions in pericardial effusion (RR 0.33 [0.27-0.41]; p < 0.00001), device-related embolism (RR 0.38 [0.23-0.60]; p < 0.0001), all-cause stroke (RR 0.75 [0.65-0.86]; p < 0.0001), ischemic stroke (RR 0.81 [0.69-0.96]; p = 0.01), major bleeding (RR 0.65 [0.53-0.81]; p < 0.0001), and all-cause mortality (RR 0.54 [0.37-0.78]; p = 0.001). DRT showed a directional but non-significant trend toward reduction (RR 0.33 [0.09-1.20]; p = 0.09). LOHS was not reliably estimable (I² = 87%).</p><p><strong>Conclusions: </strong>The Watchman FLX is associated with significantly superior safety and efficacy outcomes relative to the Watchman 2.5 across the principal clinical domains of transcatheter LAAO. These findings are observational and hypothesis-generating rather than definitive evidence of device superiority; all comparisons reflect temporal and contextual differences inherent to sequential device eras and should be interpreted with caution. These results support the design of prospective, contemporaneously enrolled comparative studies and may inform future guideline deliberations.</p>","PeriodicalId":35914,"journal":{"name":"Critical Pathways in Cardiology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical Pathways in Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/HPC.0000000000000434","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Transcatheter left atrial appendage occlusion (LAAO) prevents cardioembolic stroke in patients with non-valvular atrial fibrillation who cannot tolerate long term anticoagulation. Whether the second-generation Watchman FLX confers superior clinical outcomes over the first-generation Watchman 2.5 remains incompletely characterized.

Methods: We performed a PRISMA 2020-compliant systematic review and meta-analysis of studies comparing Watchman FLX with Watchman 2.5. Three electronic databases were searched through April 2026. Pooled risk ratios (RRs) and mean differences (MDs) with 95% confidence intervals (CIs) were derived using DerSimonian-Laird random-effects models. Nine prespecified outcomes were analyzed: procedural success, device-related embolism, device-related thrombosis (DRT), major bleeding, pericardial effusion, all-cause mortality, any stroke, ischemic stroke, and length of hospital stay (LOHS).

Results: Seven observational cohort studies enrolling 131,728 patients (Watchman FLX: n = 54,023; Watchman 2.5: n = 77,705) were included. All studies received Newcastle-Ottawa Scale scores of 8-9 (high quality). The Watchman FLX demonstrated significantly higher procedural success (RR 1.02 [1.02-1.02]; p < 0.00001) and significant reductions in pericardial effusion (RR 0.33 [0.27-0.41]; p < 0.00001), device-related embolism (RR 0.38 [0.23-0.60]; p < 0.0001), all-cause stroke (RR 0.75 [0.65-0.86]; p < 0.0001), ischemic stroke (RR 0.81 [0.69-0.96]; p = 0.01), major bleeding (RR 0.65 [0.53-0.81]; p < 0.0001), and all-cause mortality (RR 0.54 [0.37-0.78]; p = 0.001). DRT showed a directional but non-significant trend toward reduction (RR 0.33 [0.09-1.20]; p = 0.09). LOHS was not reliably estimable (I² = 87%).

Conclusions: The Watchman FLX is associated with significantly superior safety and efficacy outcomes relative to the Watchman 2.5 across the principal clinical domains of transcatheter LAAO. These findings are observational and hypothesis-generating rather than definitive evidence of device superiority; all comparisons reflect temporal and contextual differences inherent to sequential device eras and should be interpreted with caution. These results support the design of prospective, contemporaneously enrolled comparative studies and may inform future guideline deliberations.

一项比较Watchman FLX和Watchman 2.5装置经导管治疗房颤患者左心耳闭塞的临床结果的系统综述和荟萃分析。
背景:经导管左心耳闭塞术(LAAO)可预防不能耐受长期抗凝治疗的非瓣膜性心房颤动患者的心栓塞性卒中。第二代Watchman FLX是否比第一代Watchman 2.5具有更好的临床结果尚不完全确定。方法:我们对比较Watchman FLX和Watchman 2.5的研究进行了符合PRISMA 2020标准的系统评价和荟萃分析。截至2026年4月,三个电子数据库被搜索。采用dersimonan - laird随机效应模型,得出合并风险比(rr)和95%置信区间(ci)的平均差异(MDs)。分析了9个预先指定的结局:手术成功、器械相关栓塞、器械相关血栓形成(DRT)、大出血、心包积液、全因死亡率、任何卒中、缺血性卒中和住院时间(LOHS)。结果:纳入7项观察性队列研究,共纳入131,728例患者(Watchman FLX: n = 54,023; Watchman 2.5: n = 77705)。所有研究均获得纽卡斯尔-渥太华量表8-9分(高质量)。结论:在经导管LAAO的主要临床领域,与Watchman 2.5相比,Watchman FLX具有显著优于Watchman 2.5的安全性和有效性。这些发现是观察性的和假设产生的,而不是设备优势的明确证据;所有比较都反映了时序设备时代固有的时间和上下文差异,应谨慎解释。这些结果支持前瞻性、同期登记比较研究的设计,并可能为未来的指南审议提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Critical Pathways in Cardiology
Critical Pathways in Cardiology Medicine-Medicine (all)
CiteScore
1.90
自引率
0.00%
发文量
52
期刊介绍: Critical Pathways in Cardiology provides a single source for the diagnostic and therapeutic protocols in use at hospitals worldwide for patients with cardiac disorders. The Journal presents critical pathways for specific diagnoses—complete with evidence-based rationales—and also publishes studies of these protocols" effectiveness.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书