{"title":"A five-year radiostereometry study of cup fixation and implant survival in 484 Moovis trapeziometacarpal arthroplasties.","authors":"Maiken Stilling, Torben B Hansen, Janni K Thillemann","doi":"10.1177/17531934261459885","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The primary cause of revision of trapeziometacarpal arthroplasty limiting the implant survival has been aseptic cup loosening. Radiostereometry is a precise method to evaluate implant migration as a surrogate marker for aseptic implant loosening and later revision. The aim of this prospective single-centre cross-sectional cohort study was to evaluate fixation of trapeziometacarpal cups using radiostereometry, report clinical and patient reported outcomes at 5 year follow-up, and assess the complications and survival rate of the Moovis cup with up to 9 years of follow-up.</p><p><strong>Methods: </strong>Four-hundred and eighty-four conical press-fit dual-mobility Moovis trapeziometacarpal implants were inserted in 407 patients, with a mean age of 59 years (range 43-80). Tantalum beads were inserted in the trapezium during index surgery. Radiostereometric images at 3 weeks, 3 months, 1 year, 2 years and 5 years after the index surgery were used to measure cup migration. Clinical and patient reported outcomes were recorded for 5 years. The cumulative implant survival until 9 years was analysed using the Kaplan-Meier method.</p><p><strong>Results: </strong>Cup migration was 0.28 mm (95% CI: 0.25 to 0.32 mm) total translation at the 3 month follow-up and remained stable until the 5 year follow-up. Females had 0.15 mm (95% CI: 0.06 to 0.24 mm) more cup migration (total translation) than males at the 5 year follow-up. Grip strength, resting and activity pain, and Quick DASH score showed clinically relevant improvement at 1 year and remained stable until the 5 year follow-up. Medium-term patient satisfaction was 96%, and willingness to repeat the procedure was 96%. The 9 year cumulative implant survival rate was 98% for cup removal owing to aseptic loosening and 87% for removal/exchange of any implant component.</p><p><strong>Conclusion: </strong>Stable cup fixation and high patient satisfaction until 5 years combined with good 9 year survivorship for Moovis press-fit cups favour its use in the treatment of trapeziometacarpal osteoarthritis. Although these results cannot be directly extrapolated to other trapezial cups, they suggest that similar press-fit conical trapezial cup designs may also provide good fixation and favourable clinical outcomes in the treatment of painful trapeziometacarpal joint osteoarthritis, in patients between the ages of 40 and 80 years.</p><p><strong>Level of evidence: </strong>Level II.</p>","PeriodicalId":94237,"journal":{"name":"The Journal of hand surgery, European volume","volume":" ","pages":"17531934261459885"},"PeriodicalIF":1.6000,"publicationDate":"2026-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of hand surgery, European volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17531934261459885","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The primary cause of revision of trapeziometacarpal arthroplasty limiting the implant survival has been aseptic cup loosening. Radiostereometry is a precise method to evaluate implant migration as a surrogate marker for aseptic implant loosening and later revision. The aim of this prospective single-centre cross-sectional cohort study was to evaluate fixation of trapeziometacarpal cups using radiostereometry, report clinical and patient reported outcomes at 5 year follow-up, and assess the complications and survival rate of the Moovis cup with up to 9 years of follow-up.

Methods: Four-hundred and eighty-four conical press-fit dual-mobility Moovis trapeziometacarpal implants were inserted in 407 patients, with a mean age of 59 years (range 43-80). Tantalum beads were inserted in the trapezium during index surgery. Radiostereometric images at 3 weeks, 3 months, 1 year, 2 years and 5 years after the index surgery were used to measure cup migration. Clinical and patient reported outcomes were recorded for 5 years. The cumulative implant survival until 9 years was analysed using the Kaplan-Meier method.

Results: Cup migration was 0.28 mm (95% CI: 0.25 to 0.32 mm) total translation at the 3 month follow-up and remained stable until the 5 year follow-up. Females had 0.15 mm (95% CI: 0.06 to 0.24 mm) more cup migration (total translation) than males at the 5 year follow-up. Grip strength, resting and activity pain, and Quick DASH score showed clinically relevant improvement at 1 year and remained stable until the 5 year follow-up. Medium-term patient satisfaction was 96%, and willingness to repeat the procedure was 96%. The 9 year cumulative implant survival rate was 98% for cup removal owing to aseptic loosening and 87% for removal/exchange of any implant component.

Conclusion: Stable cup fixation and high patient satisfaction until 5 years combined with good 9 year survivorship for Moovis press-fit cups favour its use in the treatment of trapeziometacarpal osteoarthritis. Although these results cannot be directly extrapolated to other trapezial cups, they suggest that similar press-fit conical trapezial cup designs may also provide good fixation and favourable clinical outcomes in the treatment of painful trapeziometacarpal joint osteoarthritis, in patients between the ages of 40 and 80 years.

Level of evidence: Level II.

对484例momovis斜跖腕关节置换术患者进行为期5年的骨杯固定和假体存活的放射立体研究。
摘要:无菌杯松动是限制斜骨腕关节置换术后植入物存活的主要原因。放射立体测量法是一种精确的方法来评估种植体迁移作为无菌种植体松动和后来翻修的替代标记。这项前瞻性单中心横断面队列研究的目的是评估使用放射立体测量技术固定梯形腕关节杯,在5年随访中报告临床和患者报告的结果,并在长达9年的随访中评估Moovis杯的并发症和生存率。方法:对407例患者,平均年龄59岁(43-80岁),共植入484枚锥形压合双活动Moovis斜跖腕关节假体。在食指手术时将钽珠插入斜方骨。采用指数手术后3周、3个月、1年、2年和5年的放射立体成像测量杯杯移动。临床和患者报告的结果记录了5年。使用Kaplan-Meier法分析9年累积种植体存活率。结果:在随访3个月时,杯部移位量为0.28 mm (95% CI: 0.25 ~ 0.32 mm),并保持稳定至随访5年。在5年的随访中,女性的杯移(总平移)比男性多0.15 mm (95% CI: 0.06 ~ 0.24 mm)。握力、静息和活动疼痛、Quick DASH评分在随访1年时均有临床相关改善,并保持稳定至随访5年。中期患者满意度为96%,愿意重复手术的比例为96%。9年累积种植体存活率为98%,因无菌性松动而去除杯,87%的任何种植体组件的移除/交换。结论:Moovis压合杯固定稳定,5年患者满意度高,9年生存率高,适合用于治疗斜跖骨关节炎。虽然这些结果不能直接外推到其他的斜骨杯,但他们表明,类似的压合锥形斜骨杯设计也可以提供良好的固定和良好的临床结果,用于治疗40至80岁患者的疼痛的斜骨关节骨性关节炎。证据等级:二级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书