Evaluation of the Brix refractometer for diagnosing the failure of transfer of passive immunity in 12-h-old foals.

IF 1 4区 农林科学 Q3 VETERINARY SCIENCES
Acta veterinaria Hungarica Pub Date : 2026-07-20 Print Date: 2026-09-16 DOI:10.1556/004.2026.01271
Mehmet Akköse, Şeref İnal, Eren Karabulut, İsmail Ç Yılmaz, Ali Yağlıcı, Mert Kuzhan, Ceyhan Özbeyaz, Ufuk Kaya, Mustafa Çam
{"title":"Evaluation of the Brix refractometer for diagnosing the failure of transfer of passive immunity in 12-h-old foals.","authors":"Mehmet Akköse, Şeref İnal, Eren Karabulut, İsmail Ç Yılmaz, Ali Yağlıcı, Mert Kuzhan, Ceyhan Özbeyaz, Ufuk Kaya, Mustafa Çam","doi":"10.1556/004.2026.01271","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Failure of transfer of passive immunity (FTPI) is the most important cause of sepsis and mortality in neonatal foals.</p><p><strong>Objectives: </strong>This study aimed to evaluate the performance of the digital Brix refractometer for the diagnosis of FTPI in 12-h-old foals.</p><p><strong>Study design: </strong>Cross-sectional, diagnostic accuracy study.</p><p><strong>Methods: </strong>Jugular blood samples were collected from 124 foals at 12 ± 0.5 h after birth. IgG concentrations were estimated using a digital Brix refractometer and measured using the radial immunodiffusion test (RID). Correlation coefficients were calculated between serum Brix percentages and IgG concentrations. A receiver operating curve (ROC) was created to identify the Brix thresholds for diagnosing FTPI and to calculate the sensitivity (Se) and specificity (Sp) of the tests. Optimum thresholds were selected based on the Youden index. The area under the ROC curve (AUC) was calculated to evaluate the discrimination ability of the Brix refractometer.</p><p><strong>Results: </strong>There was a high correlation (r = 0.72) between the Brix percentages and RID IgG concentrations of the foals at 12 h after birth. The optimum threshold of the digital Brix refractometer to diagnose complete FTPI (IgG of <400 mg*dL-1) was ≤7.5% with 77.8% Se and 76.4% Sp. The optimum Brix threshold to diagnose complete/partial FTPI (IgG of <800 mg*dL-1) was ≤7.8% with 79.5% Se and 78.8% Sp. The Brix refractometer was moderately accurate in differentiating between foals with or without complete/partial FTPI (AUC ranged from 0.7 to 0.9). Alternatively, when FTPI was diagnosed with >90% sensitivity, the Brix threshold was identified as ≤8.4% for both IgG concentrations (Se 92.9% at <400 mg*dL-1; Se 90.0% at <800 mg*dL-1).</p><p><strong>Conclusion: </strong>The digital Brix refractometer detected complete and partial FTPI in 12-h-old foals with a sensitivity below 80%. This constitutes a handicap for the use of Brix refractometry in the horse industry. Future studies should compare the diagnostic accuracy of on-site tests, directly measuring IgG concentrations and refractometry in newborn foals and conduct a cost-benefit analysis of the combined use of these methods.</p>","PeriodicalId":7247,"journal":{"name":"Acta veterinaria Hungarica","volume":" ","pages":"171-178"},"PeriodicalIF":1.0000,"publicationDate":"2026-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta veterinaria Hungarica","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1556/004.2026.01271","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/16 0:00:00","PubModel":"Print","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Failure of transfer of passive immunity (FTPI) is the most important cause of sepsis and mortality in neonatal foals.

Objectives: This study aimed to evaluate the performance of the digital Brix refractometer for the diagnosis of FTPI in 12-h-old foals.

Study design: Cross-sectional, diagnostic accuracy study.

Methods: Jugular blood samples were collected from 124 foals at 12 ± 0.5 h after birth. IgG concentrations were estimated using a digital Brix refractometer and measured using the radial immunodiffusion test (RID). Correlation coefficients were calculated between serum Brix percentages and IgG concentrations. A receiver operating curve (ROC) was created to identify the Brix thresholds for diagnosing FTPI and to calculate the sensitivity (Se) and specificity (Sp) of the tests. Optimum thresholds were selected based on the Youden index. The area under the ROC curve (AUC) was calculated to evaluate the discrimination ability of the Brix refractometer.

Results: There was a high correlation (r = 0.72) between the Brix percentages and RID IgG concentrations of the foals at 12 h after birth. The optimum threshold of the digital Brix refractometer to diagnose complete FTPI (IgG of <400 mg*dL-1) was ≤7.5% with 77.8% Se and 76.4% Sp. The optimum Brix threshold to diagnose complete/partial FTPI (IgG of <800 mg*dL-1) was ≤7.8% with 79.5% Se and 78.8% Sp. The Brix refractometer was moderately accurate in differentiating between foals with or without complete/partial FTPI (AUC ranged from 0.7 to 0.9). Alternatively, when FTPI was diagnosed with >90% sensitivity, the Brix threshold was identified as ≤8.4% for both IgG concentrations (Se 92.9% at <400 mg*dL-1; Se 90.0% at <800 mg*dL-1).

Conclusion: The digital Brix refractometer detected complete and partial FTPI in 12-h-old foals with a sensitivity below 80%. This constitutes a handicap for the use of Brix refractometry in the horse industry. Future studies should compare the diagnostic accuracy of on-site tests, directly measuring IgG concentrations and refractometry in newborn foals and conduct a cost-benefit analysis of the combined use of these methods.

Brix折射仪诊断12 h马驹被动免疫转移失败的评价。
背景:被动免疫转移失败(FTPI)是新生儿马驹败血症和死亡的最重要原因。目的:本研究旨在评估数字Brix折射计在12 h马驹FTPI诊断中的性能。研究设计:横断面、诊断准确性研究。方法:124匹马驹在出生后12±0.5 h采集颈静脉血样。IgG浓度用数字Brix折射仪估计,用径向免疫扩散试验(RID)测量。计算血清白锐度百分比与IgG浓度之间的相关系数。建立受试者工作曲线(ROC),以确定诊断FTPI的Brix阈值,并计算检测的敏感性(Se)和特异性(Sp)。根据约登指数选择最佳阈值。通过计算ROC曲线下面积(AUC)来评价Brix折射仪的分辨能力。结果:马驹出生后12 h白垩百分比与RID IgG浓度呈高度相关(r = 0.72)。数字Brix折射仪诊断完全FTPI的最佳阈值(IgG的灵敏度为90%),两种IgG浓度的Brix阈值均≤8.4% (Se为92.9%)。结论:数字Brix折射仪检测12 h龄马驹完全FTPI和部分FTPI的灵敏度均低于80%。这构成了Brix折射法在马业中使用的一个障碍。未来的研究应比较现场检测、直接测量IgG浓度和新生马驹折射法的诊断准确性,并对这些方法的联合使用进行成本效益分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta veterinaria Hungarica
Acta veterinaria Hungarica 农林科学-兽医学
CiteScore
1.80
自引率
0.00%
发文量
39
审稿时长
>36 weeks
期刊介绍: Acta Veterinaria Hungarica publishes original research papers presenting new scientific results of international interest, and to a limited extent also review articles and clinical case reports, on veterinary physiology (physiological chemistry and metabolism), veterinary microbiology (bacteriology, virology, immunology, molecular biology), on the infectious diseases of domestic animals, on veterinary parasitology, pathology, clinical veterinary science and reproduction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书