{"title":"Active Noise Cancellation in Ultra-Low Field MRI: Distinct Strategies for Different Channels","authors":"Jiali He;Sheng Shen;Jiamin Wu;Yamei Dai;Liang Tan;Zheng Xu","doi":"10.1109/TMI.2026.3714814","DOIUrl":null,"url":null,"abstract":"Ultra-low field magnetic resonance imaging (ULF-MRI) systems operating in open environments are highly susceptible to composite electromagnetic interference (EMI). Different imaging channels respond non-uniformly to EMI owing to their distinct coupling characteristics. Here, we investigate channel-specific interference pathways in a permanent–magnet–based low-field MRI system and show that saddle coils are intrinsically more vulnerable to transverse EMI components than solenoidal coils. To mitigate these heterogeneous coupling effects, we propose a dual-stage suppression strategy that combines front-end spatial-domain inverse field reconstruction with back-end channel-adaptive active noise cancellation. Experiments demonstrate that this approach suppresses EMI by more than 80%, substantially improves inter-channel signal-to-noise ratio (SNR) consistency, and enhances the fused-image SNR by ~24%. These findings elucidate the channel-dependent nature of EMI coupling and establish targeted mitigation strategies, providing both a theoretical basis and practical guidance for noise suppression in future array-coil ULF-MRI systems.","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"45 10","pages":"5084-5096"},"PeriodicalIF":0.0000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11614572/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/20 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Ultra-low field magnetic resonance imaging (ULF-MRI) systems operating in open environments are highly susceptible to composite electromagnetic interference (EMI). Different imaging channels respond non-uniformly to EMI owing to their distinct coupling characteristics. Here, we investigate channel-specific interference pathways in a permanent–magnet–based low-field MRI system and show that saddle coils are intrinsically more vulnerable to transverse EMI components than solenoidal coils. To mitigate these heterogeneous coupling effects, we propose a dual-stage suppression strategy that combines front-end spatial-domain inverse field reconstruction with back-end channel-adaptive active noise cancellation. Experiments demonstrate that this approach suppresses EMI by more than 80%, substantially improves inter-channel signal-to-noise ratio (SNR) consistency, and enhances the fused-image SNR by ~24%. These findings elucidate the channel-dependent nature of EMI coupling and establish targeted mitigation strategies, providing both a theoretical basis and practical guidance for noise suppression in future array-coil ULF-MRI systems.