{"title":"Automated quality assurance for emergency department documentation: pilot comparison with physician peer review of simulated chest pain cases.","authors":"Yara Mohajerani, Seyed-Alireza Mohajerani, Stephenson Strobel, Corrine Mitges, Craig Brick, Suneel Upadhye, Roveena Sequeira, Melanie Senechal, Paulo De Gouveia","doi":"10.1007/s43678-026-01230-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the feasibility and reliability of an artificial intelligence-driven quality assurance system for emergency chest pain documentation in simulated cases, compared to traditional physician reviewers.</p><p><strong>Methods: </strong>We developed an automated quality assurance solution leveraging commercial Large Language Models that are customized based on College of Physicians and Surgeons of Ontario peer review standards. Seventeen simulated emergency chest pain cases of varying quality were independently reviewed by an automated auditor, six community emergency physicians, and original case writers using a 3-point evaluation scale across nine dimensions. Agreement was measured using Lin's Concordance Correlation Coefficient for overall score agreement, Root Mean Square Error for overall score accuracy, and Cohen's Kappa statistics for categorical dimension scores.</p><p><strong>Results: </strong>Inter-rater agreement among human reviewers showed substantial variability with overall score concordances ranging from 0.28 to 0.86. The automated auditor demonstrated agreement levels within the range of human variability within the limited sample of simulated cases with the best performing model (guideline-customized Claude Sonnet 4) with a concordance value of 0.85 and root mean square error of 0.25 with respect to the average human scores on the 3-point scale. For pass/fail decisions, agreement with human reviewers ranged from 65 to 94% with Kappa scores of 0.27 to 0.85, comparable to inter-human reviewer agreement Kappa scores of - 0.12 to 0.68.</p><p><strong>Conclusions: </strong>The performance of the automated auditor showed agreement within the range of variability observed among that of the small group of uncalibrated human reviewers for the simulated cases in determining documentation quality and pass/fail outcomes. Given the potential variability in human assessments, automated quality assurance may provide a more consistent evaluation of quality, with the added advantage of the mass-processing of many cases in near real-time.</p>","PeriodicalId":93937,"journal":{"name":"CJEM","volume":" ","pages":"982-987"},"PeriodicalIF":2.0000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CJEM","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s43678-026-01230-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the feasibility and reliability of an artificial intelligence-driven quality assurance system for emergency chest pain documentation in simulated cases, compared to traditional physician reviewers.

Methods: We developed an automated quality assurance solution leveraging commercial Large Language Models that are customized based on College of Physicians and Surgeons of Ontario peer review standards. Seventeen simulated emergency chest pain cases of varying quality were independently reviewed by an automated auditor, six community emergency physicians, and original case writers using a 3-point evaluation scale across nine dimensions. Agreement was measured using Lin's Concordance Correlation Coefficient for overall score agreement, Root Mean Square Error for overall score accuracy, and Cohen's Kappa statistics for categorical dimension scores.

Results: Inter-rater agreement among human reviewers showed substantial variability with overall score concordances ranging from 0.28 to 0.86. The automated auditor demonstrated agreement levels within the range of human variability within the limited sample of simulated cases with the best performing model (guideline-customized Claude Sonnet 4) with a concordance value of 0.85 and root mean square error of 0.25 with respect to the average human scores on the 3-point scale. For pass/fail decisions, agreement with human reviewers ranged from 65 to 94% with Kappa scores of 0.27 to 0.85, comparable to inter-human reviewer agreement Kappa scores of - 0.12 to 0.68.

Conclusions: The performance of the automated auditor showed agreement within the range of variability observed among that of the small group of uncalibrated human reviewers for the simulated cases in determining documentation quality and pass/fail outcomes. Given the potential variability in human assessments, automated quality assurance may provide a more consistent evaluation of quality, with the added advantage of the mass-processing of many cases in near real-time.

急诊科文档的自动质量保证:模拟胸痛病例的试点比较与医师同行评议。
目的:与传统的医师审稿人相比,评估人工智能驱动的质量保证系统在模拟病例中用于急诊胸痛记录的可行性和可靠性。方法:我们开发了一个自动化的质量保证解决方案,利用商业大型语言模型,该模型是基于安大略省内科医生和外科医生学院同行评审标准定制的。17例不同质量的模拟急诊胸痛病例由自动审核员、6名社区急诊医生和原始病例作者独立审查,使用3点评估量表跨越9个维度。使用Lin’s Concordance Correlation Coefficient衡量总分一致性,使用均方根误差衡量总分准确性,使用Cohen’s Kappa统计量衡量分类维度得分。结果:人类审稿人之间的评分一致性显示出实质性的差异,总体评分一致性范围为0.28至0.86。自动审核员在有限的模拟案例样本中展示了人类可变性范围内的协议水平,该样本具有最佳表现模型(指南定制的Claude Sonnet 4),相对于3分制的平均人类分数,其一致性值为0.85,均方根误差为0.25。对于通过/不通过的决定,与人类审稿人的一致性在65%到94%之间,Kappa分数为0.27到0.85,与人类审稿人之间的一致性Kappa分数为- 0.12到0.68相当。结论:在确定文档质量和通过/不通过结果的模拟案例中,自动审核员的性能显示了在观察到的可变性范围内的一致性。考虑到人类评估的潜在可变性,自动化质量保证可以提供更一致的质量评估,并具有近实时大量处理许多病例的附加优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书