{"title":"Vibration response control of buildings using tuned inerter dampers","authors":"Pranav R. Sable,&nbsp;Ashish R. Akhare","doi":"10.1007/s42107-026-01695-7","DOIUrl":null,"url":null,"abstract":"<div><p>Multi-storey buildings often experience significant vibrations due to their flexible nature and exposure to earthquake and wind loads. These vibrations can affect structural safety and serviceability. Passive vibration control systems are commonly used due to their simple design and reliable performance. However, traditional tuned mass dampers have limitations related to the requirement of additional mass. Tuned inerter dampers provide an alternative solution by producing high inertial forces without adding much physical mass. This study examines how a nine degree of freedom shear building responds to vibrations when a tuned inerter damper is used. The building is subjected to base excitation, and its dynamic behaviour is examined through frequency-domain analysis. The damper is placed at the bottom and top storeys to study the effect of installation location. The influence of different inertance ratios on the structural response is also examined. The performance of the system is evaluated using normalized maximum displacement and inter-storey drift. The results show that placing the damper at the bottom storey gives a noticeable reduction in displacement and drift, even for small inertance ratios. On the other hand, when the damper is installed at the top storey, higher inertance values are required to obtain meaningful vibration reduction. The results show that the position of the damper and the inertance ratio are both important for controlling vibrations in a multi degree of freedom building.</p></div>","PeriodicalId":8513,"journal":{"name":"Asian Journal of Civil Engineering","volume":"27 8","pages":"3775 - 3793"},"PeriodicalIF":0.0000,"publicationDate":"2026-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1007/s42107-026-01695-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Multi-storey buildings often experience significant vibrations due to their flexible nature and exposure to earthquake and wind loads. These vibrations can affect structural safety and serviceability. Passive vibration control systems are commonly used due to their simple design and reliable performance. However, traditional tuned mass dampers have limitations related to the requirement of additional mass. Tuned inerter dampers provide an alternative solution by producing high inertial forces without adding much physical mass. This study examines how a nine degree of freedom shear building responds to vibrations when a tuned inerter damper is used. The building is subjected to base excitation, and its dynamic behaviour is examined through frequency-domain analysis. The damper is placed at the bottom and top storeys to study the effect of installation location. The influence of different inertance ratios on the structural response is also examined. The performance of the system is evaluated using normalized maximum displacement and inter-storey drift. The results show that placing the damper at the bottom storey gives a noticeable reduction in displacement and drift, even for small inertance ratios. On the other hand, when the damper is installed at the top storey, higher inertance values are required to obtain meaningful vibration reduction. The results show that the position of the damper and the inertance ratio are both important for controlling vibrations in a multi degree of freedom building.

调谐阻尼器对建筑物振动响应的控制
多层建筑由于其灵活的性质和暴露在地震和风荷载下,经常经历显著的振动。这些振动会影响结构的安全性和适用性。被动振动控制系统因其设计简单、性能可靠而被广泛应用。然而,传统的调谐质量阻尼器具有与附加质量要求相关的局限性。调谐的干涉阻尼器通过产生高惯性力而不增加太多物理质量提供了另一种解决方案。本研究探讨了一个九自由度的剪切建筑如何响应振动时,调谐干涉阻尼器的使用。该建筑物受到基础激励,并通过频域分析对其动力性能进行了检测。在底部和顶部设置阻尼器,研究安装位置的影响。研究了不同的惰性比对结构响应的影响。采用归一化最大位移和层间位移对系统性能进行了评价。结果表明,即使在较小的惯性比下,将阻尼器放置在底层也能显著减少位移和漂移。另一方面,当阻尼器安装在顶层时,需要更高的惯性值以获得有意义的减振。结果表明,阻尼器的位置和惯性比对多自由度建筑物的振动控制都很重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Asian Journal of Civil Engineering
Asian Journal of Civil Engineering Engineering-Civil and Structural Engineering
CiteScore
2.70
自引率
0.00%
发文量
121
期刊介绍: The Asian Journal of Civil Engineering (Building and Housing) welcomes articles and research contributions on topics such as:- Structural analysis and design - Earthquake and structural engineering - New building materials and concrete technology - Sustainable building and energy conservation - Housing and planning - Construction management - Optimal design of structuresPlease note that the journal will not accept papers in the area of hydraulic or geotechnical engineering, traffic/transportation or road making engineering, and on materials relevant to non-structural buildings, e.g. materials for road making and asphalt.  Although the journal will publish authoritative papers on theoretical and experimental research works and advanced applications, it may also feature, when appropriate:  a) tutorial survey type papers reviewing some fields of civil engineering; b) short communications and research notes; c) book reviews and conference announcements.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书