Development of a sensitive plasma lenvatinib quantification method and validation in thyroid cancer patients.

IF 4.4 Q2 ENDOCRINOLOGY & METABOLISM
Journal of the Endocrine Society Pub Date : 2026-07-06 eCollection Date: 2026-08-01 DOI:10.1210/jendso/bvag154
Carla Colombo, Roberta Ottria, Matteo Trevisan, Erika Carbone, Claudia Moneta, Marina Lugaresi, Sara Casati, Sofia Vanerio, Daniele Ceruti, Massimiliano Succi, Valentina Cirello, Simone De Leo, Luca Persani, Pierangela Ciuffreda, Laura Fugazzola
{"title":"Development of a sensitive plasma lenvatinib quantification method and validation in thyroid cancer patients.","authors":"Carla Colombo, Roberta Ottria, Matteo Trevisan, Erika Carbone, Claudia Moneta, Marina Lugaresi, Sara Casati, Sofia Vanerio, Daniele Ceruti, Massimiliano Succi, Valentina Cirello, Simone De Leo, Luca Persani, Pierangela Ciuffreda, Laura Fugazzola","doi":"10.1210/jendso/bvag154","DOIUrl":null,"url":null,"abstract":"<p><strong>Context: </strong>Lenvatinib (LEN) is effective in the treatment of radioactive iodine refractory differentiated thyroid cancer (DTC), though it is associated with frequent and potentially severe adverse events (AEs). The dose dependency of LEN-related toxicity remains unclear, since no data are available on this topic.</p><p><strong>Objective: </strong>This study aimed to investigate the relationship between LEN dose and plasma concentrations in real-life patients by a novel and validated method for quantifying LEN in plasma samples.</p><p><strong>Design and setting: </strong>A sensitive high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assay for LEN quantification in plasma was set up, with a wide analytical range (0.7-500 ng/mL). Consecutive plasma samples from 19 patients with radioactive iodine-refractory, metastatic DTC were analyzed.</p><p><strong>Results: </strong>A positive correlation between the administered LEN dose and plasma concentrations was found, particularly in patients on low doses (<18 mg daily). Linear mixed-effects models (LMMs) demonstrated significant interindividual variability in plasma LEN concentrations, contributing to 17% to 28% of the total variance. This variability was more pronounced at higher doses (≥18 mg), being more likely the consequence of LEN-related AEs than of a dose-dependent effect.</p><p><strong>Conclusion: </strong>This is the first real-life evaluation of interindividual LEN pharmacokinetics variability in advanced DTC patients, obtained by means of the newly developed HPLC-MS/MS method. Our results suggest that the dose-response relationship of LEN in radioactive iodine-refractory DTC may be more complex than previously understood, with substantial interpatient variability and dose-dependent effects. Further studies are needed to determine the implications of our findings in the clinical management of these patients.</p>","PeriodicalId":17334,"journal":{"name":"Journal of the Endocrine Society","volume":"10 8","pages":"bvag154"},"PeriodicalIF":4.4000,"publicationDate":"2026-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13370831/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Endocrine Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1210/jendso/bvag154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Context: Lenvatinib (LEN) is effective in the treatment of radioactive iodine refractory differentiated thyroid cancer (DTC), though it is associated with frequent and potentially severe adverse events (AEs). The dose dependency of LEN-related toxicity remains unclear, since no data are available on this topic.

Objective: This study aimed to investigate the relationship between LEN dose and plasma concentrations in real-life patients by a novel and validated method for quantifying LEN in plasma samples.

Design and setting: A sensitive high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assay for LEN quantification in plasma was set up, with a wide analytical range (0.7-500 ng/mL). Consecutive plasma samples from 19 patients with radioactive iodine-refractory, metastatic DTC were analyzed.

Results: A positive correlation between the administered LEN dose and plasma concentrations was found, particularly in patients on low doses (<18 mg daily). Linear mixed-effects models (LMMs) demonstrated significant interindividual variability in plasma LEN concentrations, contributing to 17% to 28% of the total variance. This variability was more pronounced at higher doses (≥18 mg), being more likely the consequence of LEN-related AEs than of a dose-dependent effect.

Conclusion: This is the first real-life evaluation of interindividual LEN pharmacokinetics variability in advanced DTC patients, obtained by means of the newly developed HPLC-MS/MS method. Our results suggest that the dose-response relationship of LEN in radioactive iodine-refractory DTC may be more complex than previously understood, with substantial interpatient variability and dose-dependent effects. Further studies are needed to determine the implications of our findings in the clinical management of these patients.

甲状腺癌患者血浆lenvatinib定量方法的建立及验证。
背景:Lenvatinib (LEN)在治疗放射性碘难治性分化甲状腺癌(DTC)方面是有效的,尽管它与频繁和潜在的严重不良事件(ae)相关。len相关毒性的剂量依赖性尚不清楚,因为没有关于这一主题的数据。目的:本研究旨在通过一种新的、经过验证的血浆样本LEN定量方法,探讨现实患者中LEN剂量与血浆浓度之间的关系。设计与设置:建立了血浆中LEN定量的高效液相色谱-串联质谱(HPLC-MS/MS)分析方法,分析范围宽(0.7 ~ 500 ng/mL)。对19例放射性碘难治性转移性DTC患者的连续血浆样本进行了分析。结果:发现给药LEN剂量与血浆浓度呈正相关,特别是在低剂量患者中(结论:这是通过新开发的HPLC-MS/MS方法获得的晚期DTC患者个体间LEN药代动力学变异性的首次现实评估。我们的研究结果表明,放射性碘难治性DTC中LEN的剂量-反应关系可能比以前理解的更为复杂,具有大量的患者间变异性和剂量依赖效应。需要进一步的研究来确定我们的发现对这些患者的临床管理的意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of the Endocrine Society
Journal of the Endocrine Society Medicine-Endocrinology, Diabetes and Metabolism
CiteScore
5.50
自引率
0.00%
发文量
2039
审稿时长
9 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书