Transcatheter dual-device closure for symptomatic iatrogenic atrial septal defect following bioprosthetic mitral valve replacement: a case report.

IF 4.6 Q3 ENGINEERING, BIOMEDICAL
Frontiers in medical technology Pub Date : 2026-06-30 eCollection Date: 2026-01-01 DOI:10.3389/fmedt.2026.1847831
Ping-An Lian, Shan-Fu Liang, Fei Xie, Shuai Cheng, Zhan-Zhan Zhu, Yun-Fei Zhao, Lei Yin, Shen-Wei Zhang
{"title":"Transcatheter dual-device closure for symptomatic iatrogenic atrial septal defect following bioprosthetic mitral valve replacement: a case report.","authors":"Ping-An Lian, Shan-Fu Liang, Fei Xie, Shuai Cheng, Zhan-Zhan Zhu, Yun-Fei Zhao, Lei Yin, Shen-Wei Zhang","doi":"10.3389/fmedt.2026.1847831","DOIUrl":null,"url":null,"abstract":"<p><p>Iatrogenic atrial septal defect (iASD) is a relatively common complication after cardiac surgical or catheter-based procedures involving transseptal access. While most defects close spontaneously, a subset may persist and become hemodynamically significant, leading to clinical deterioration and necessitating intervention. We report a case of a large, persistent iASD that led to progressive right-sided heart failure following bioprosthetic mitral valve replacement combined with tricuspid annuloplasty. A 69-year-old male underwent bioprosthetic mitral valve replacement and tricuspid annuloplasty. Postoperatively, the patient developed a large, persistent iASD, which contributed to severe right-sided heart failure. The patient also had end-stage liver disease, portal hypertension, and severe coagulopathy, which made reoperation extremely high-risk. After heart team evaluation, a transcatheter closure approach was chosen. Initially, a 24-mm occluder was deployed, but significant residual shunting remained. A planned two-device strategy was then performed, resulting in complete closure of the defect. Post-procedure imaging confirmed the absence of residual shunt, and tricuspid regurgitation significantly improved. The patient's symptoms improved to New York Heart Association NYHA I-II, and at six-month follow-up, the device remained stable, and cardiac function had recovered. This case illustrates that in patients with large, complex, or poorly rimmed iASDs, particularly those who are not suitable candidates for reoperation, the dual-device strategy represents a safe and effective percutaneous alternative.</p>","PeriodicalId":94015,"journal":{"name":"Frontiers in medical technology","volume":"8 ","pages":"1847831"},"PeriodicalIF":4.6000,"publicationDate":"2026-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13364760/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in medical technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fmedt.2026.1847831","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Iatrogenic atrial septal defect (iASD) is a relatively common complication after cardiac surgical or catheter-based procedures involving transseptal access. While most defects close spontaneously, a subset may persist and become hemodynamically significant, leading to clinical deterioration and necessitating intervention. We report a case of a large, persistent iASD that led to progressive right-sided heart failure following bioprosthetic mitral valve replacement combined with tricuspid annuloplasty. A 69-year-old male underwent bioprosthetic mitral valve replacement and tricuspid annuloplasty. Postoperatively, the patient developed a large, persistent iASD, which contributed to severe right-sided heart failure. The patient also had end-stage liver disease, portal hypertension, and severe coagulopathy, which made reoperation extremely high-risk. After heart team evaluation, a transcatheter closure approach was chosen. Initially, a 24-mm occluder was deployed, but significant residual shunting remained. A planned two-device strategy was then performed, resulting in complete closure of the defect. Post-procedure imaging confirmed the absence of residual shunt, and tricuspid regurgitation significantly improved. The patient's symptoms improved to New York Heart Association NYHA I-II, and at six-month follow-up, the device remained stable, and cardiac function had recovered. This case illustrates that in patients with large, complex, or poorly rimmed iASDs, particularly those who are not suitable candidates for reoperation, the dual-device strategy represents a safe and effective percutaneous alternative.

经导管双装置关闭治疗生物二尖瓣置换术后症状性医源性房间隔缺损1例报告。
医源性房间隔缺损(iASD)是心脏手术或导管手术后相对常见的并发症。虽然大多数缺陷会自发愈合,但有一部分缺陷可能会持续存在,并在血流动力学上变得重要,从而导致临床恶化,需要进行干预。我们报告一例大的持续性isd,在生物假体二尖瓣置换术联合三尖瓣环成形术后导致进行性右侧心力衰竭。一位69岁男性接受了生物假体二尖瓣置换术和三尖瓣环成形术。术后,患者出现大而持久的isd,导致严重的右侧心力衰竭。患者同时伴有终末期肝病、门静脉高压症和严重凝血功能障碍,再次手术风险极高。经心脏科评估,选择经导管闭合入路。最初,使用了24mm闭塞器,但仍然存在明显的分流现象。然后执行计划的双装置策略,导致缺陷完全闭合。术后影像学证实没有残留分流,三尖瓣返流明显改善。患者症状改善至纽约心脏协会NYHA I-II级,随访6个月,该装置保持稳定,心功能恢复。该病例表明,对于较大、复杂或边缘较差的ids患者,特别是那些不适合再手术的患者,双装置策略是一种安全有效的经皮替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.70
自引率
0.00%
发文量
0
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书