Yuchen Cao, Masaaki Koide, Masafumi Yashima, Aya Miyazaki
{"title":"Asymmetric calcification of the extracardiac Fontan conduit: Quantitative insights from long-term computed tomography imaging.","authors":"Yuchen Cao, Masaaki Koide, Masafumi Yashima, Aya Miyazaki","doi":"10.4103/apc.apc_114_26","DOIUrl":null,"url":null,"abstract":"<p><p>The long-term structural integrity of expanded polytetrafluoroethylene (ePTFE) conduits used for extracardiac total cavopulmonary connection (EC-TCPC) is not well established. Although conduit calcification has been reported, quantitative data remain limited. We retrospectively analyzed 20 EC-TCPC patients who underwent computed tomography more than 5 years after Fontan completion (median: 13.7 years). Cross-sectional area (CSA) was measured at five sites and expressed as a percentage of the original CSA (%CSA), and calcification volume was indexed to body surface area. Median values of mean and minimum %CSA were 74.0% and 65.5%, respectively. %CSA correlated inversely with calcification volume index (ρ = -0.47, <i>P</i> = 0.04). Calcification was greater along the lesser curvature than the greater curvature (0.66 vs. 0.20 mm<sup>3</sup>/m<sup>2</sup>, <i>P</i> < 0.001). These findings suggest curvature-specific vulnerability in ePTFE conduits and support the importance of long-term structural surveillance in Fontan patients.</p>","PeriodicalId":8026,"journal":{"name":"Annals of Pediatric Cardiology","volume":"19 2","pages":"193-197"},"PeriodicalIF":0.8000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13331499/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Pediatric Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/apc.apc_114_26","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
The long-term structural integrity of expanded polytetrafluoroethylene (ePTFE) conduits used for extracardiac total cavopulmonary connection (EC-TCPC) is not well established. Although conduit calcification has been reported, quantitative data remain limited. We retrospectively analyzed 20 EC-TCPC patients who underwent computed tomography more than 5 years after Fontan completion (median: 13.7 years). Cross-sectional area (CSA) was measured at five sites and expressed as a percentage of the original CSA (%CSA), and calcification volume was indexed to body surface area. Median values of mean and minimum %CSA were 74.0% and 65.5%, respectively. %CSA correlated inversely with calcification volume index (ρ = -0.47, P = 0.04). Calcification was greater along the lesser curvature than the greater curvature (0.66 vs. 0.20 mm3/m2, P < 0.001). These findings suggest curvature-specific vulnerability in ePTFE conduits and support the importance of long-term structural surveillance in Fontan patients.
用于心外全腔肺连接(EC-TCPC)的膨胀聚四氟乙烯(ePTFE)导管的长期结构完整性尚未得到很好的确定。虽然有导管钙化的报道,但定量数据仍然有限。我们回顾性分析了20例EC-TCPC患者,这些患者在Fontan完成手术5年后接受了计算机断层扫描(中位数:13.7年)。测量五个部位的横截面积(CSA),并以原始CSA的百分比(%CSA)表示,钙化体积与体表面积相关。平均和最小%CSA的中位数分别为74.0%和65.5%。%CSA与钙化体积指数呈负相关(ρ = -0.47, P = 0.04)。小曲率处钙化程度高于大曲率处(0.66 vs. 0.20 mm3/m2, P < 0.001)。这些发现表明ePTFE导管具有曲率特异性易感性,并支持对Fontan患者进行长期结构监测的重要性。