Effects of medium thickness on cellular energy deposition in boron neutron capture therapy.

IF 1.6 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Radiological Physics and Technology Pub Date : 2026-09-01 Epub Date: 2026-07-04 DOI:10.1007/s12194-026-01091-5
Maheraj Khan, Hiroshi Watabe, Peter K N Yu, A K F Haque, M Ismail Hossain, M Rafiqul Islam, Gary Tse, Mehrdad Shahmohammadi Beni
{"title":"Effects of medium thickness on cellular energy deposition in boron neutron capture therapy.","authors":"Maheraj Khan, Hiroshi Watabe, Peter K N Yu, A K F Haque, M Ismail Hossain, M Rafiqul Islam, Gary Tse, Mehrdad Shahmohammadi Beni","doi":"10.1007/s12194-026-01091-5","DOIUrl":null,"url":null,"abstract":"<p><p>Boron Neutron Capture Therapy is dependent on localized energy deposition of alpha particles and lithium nuclei. However, deviations and inconsistencies in cellular responses to neutron beams are frequently reported in radiobiological studies. This technical note investigates dosimetric impact of the overlying medium thickness on a [Formula: see text] cellular array using Monte Carlo method. [Formula: see text]B concentrations ranging from 0 to 80 ppm were evaluated to explicitly quantify energy partitioning between the cytoplasm and nucleus. Our findings demonstrate that minor variations in the aqueous medium layer severely attenuate the thermal neutron flux, leading to a marked decrease in the absolute dose deposited in the cellular targets. Specifically, increasing the medium thickness from 100 μm to 800 μm resulted in a [Formula: see text] reduction in the total cellular dose at 80 ppm. These results highlight the critical necessity of controlling and reporting fluid levels in BNCT in vitro experiments to prevent dosimetric variations and ensure reproducible biological outcomes.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":"1421-1426"},"PeriodicalIF":1.6000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13546304/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-026-01091-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Boron Neutron Capture Therapy is dependent on localized energy deposition of alpha particles and lithium nuclei. However, deviations and inconsistencies in cellular responses to neutron beams are frequently reported in radiobiological studies. This technical note investigates dosimetric impact of the overlying medium thickness on a [Formula: see text] cellular array using Monte Carlo method. [Formula: see text]B concentrations ranging from 0 to 80 ppm were evaluated to explicitly quantify energy partitioning between the cytoplasm and nucleus. Our findings demonstrate that minor variations in the aqueous medium layer severely attenuate the thermal neutron flux, leading to a marked decrease in the absolute dose deposited in the cellular targets. Specifically, increasing the medium thickness from 100 μm to 800 μm resulted in a [Formula: see text] reduction in the total cellular dose at 80 ppm. These results highlight the critical necessity of controlling and reporting fluid levels in BNCT in vitro experiments to prevent dosimetric variations and ensure reproducible biological outcomes.

硼中子俘获治疗中介质厚度对细胞能量沉积的影响。
硼中子俘获疗法依赖于α粒子和锂核的局部能量沉积。然而,在放射生物学研究中,细胞对中子束反应的偏差和不一致经常被报道。本技术说明用蒙特卡罗方法研究了上覆介质厚度对蜂窝阵列的剂量学影响。[公式:见文本]B浓度范围为0至80 ppm,以明确量化细胞质和细胞核之间的能量分配。我们的研究结果表明,水介质层的微小变化严重削弱了热中子通量,导致沉积在细胞靶中的绝对剂量显著减少。具体来说,将介质厚度从100 μm增加到800 μm,导致80 ppm时细胞总剂量减少。这些结果强调了在BNCT体外实验中控制和报告体液水平的关键必要性,以防止剂量学变化并确保可重复的生物学结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiological Physics and Technology
Radiological Physics and Technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
12.50%
发文量
40
期刊介绍: The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书