An Engineered Glove for the Objective Assessment of Hand Dexterity in Patients With Systemic Sclerosis.

IF 2.9 Q2 RHEUMATOLOGY
Alberto Sulli, Elvis Hysa, Paolo Clini, Emanuele Gotelli, Tamara Vojinovic, Carmen Pizzorni, Ali Jaffal, Sabrina Paolino, Rosanna Campitiello, Vanessa Smith, Maurizio Cutolo
{"title":"An Engineered Glove for the Objective Assessment of Hand Dexterity in Patients With Systemic Sclerosis.","authors":"Alberto Sulli, Elvis Hysa, Paolo Clini, Emanuele Gotelli, Tamara Vojinovic, Carmen Pizzorni, Ali Jaffal, Sabrina Paolino, Rosanna Campitiello, Vanessa Smith, Maurizio Cutolo","doi":"10.1002/acr2.90082","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Hand disability is a major musculoskeletal functional impairment in systemic sclerosis (SSc), but its objective assessment remains challenging. The validated Hand Test System (HTS) engineered glove has provided quantitative dexterity data in rheumatic diseases. The primary objective was to evaluate the applicability of the HTS glove in patients with SSc by comparing its parameters (touch duration [TD], intertapping interval [ITI], and movement rate [MR]) with healthy controls (HCs). The assumptions were that HTS parameters would be significantly impaired in patients with SSc and would correlate with clinical, imaging, and patient-reported outcome measures (PROMs).</p><p><strong>Methods: </strong>A cross-sectional study was conducted enrolling 25 patients with SSc (fulfilling 2013 American College of Rheumatology/EULAR criteria) and 25 matched HCs. The main outcome variables were the HTS glove parameters. All participants also underwent grip strength measurement and an assessment of PROMs (Scleroderma Health Assessment Questionnaire and Duruöz Hand Index), together with a performance-based evaluation of hand mobility using the Hand Mobility in Scleroderma test. Clinical and imaging data were collected for patients with SSc including the modified Rodnan skin score (mRSS) and high-frequency skin ultrasonography (HFSU) to measure hand and total body dermal thickness.</p><p><strong>Results: </strong>Patients with SSc performed finger movements significantly more slowly and less efficiently than HCs, demonstrated by prolonged mean TD and ITI and reduced MR (P < 0.05 for all). In patients with SSc, HTS parameters significantly correlated with poorer PROMs (0.39 < r < 0.65, all P < 0.01 for all). Notably, both mean TD and ITI directly correlated with the mRSS (0.40 < r < 0.48, all P < 0.05). Furthermore, the mean TD showed a significant direct correlation with HFSU-measured dermal thickness of the dorsum of the hands and with total body dermal thickness (P < 0.05 for all). No significant differences in HTS parameters were detected based on nailfold videocapillaroscopy findings or organ involvement.</p><p><strong>Conclusion: </strong>The HTS glove provides objective measures of the impaired hand dexterity in SSc. The significant correlations between HTS parameters, PROMs, mRSS, and HFSU-measured dermal thickness suggest a significant relationship between skin fibrosis and functional hand disability. The HTS glove seems a promising tool for objectively monitoring SSc hand outcomes, and studies to explore its utility in monitoring therapeutic responses are in progression.</p>","PeriodicalId":93845,"journal":{"name":"ACR open rheumatology","volume":"8 7","pages":"e90082"},"PeriodicalIF":2.9000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13329684/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACR open rheumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/acr2.90082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RHEUMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Hand disability is a major musculoskeletal functional impairment in systemic sclerosis (SSc), but its objective assessment remains challenging. The validated Hand Test System (HTS) engineered glove has provided quantitative dexterity data in rheumatic diseases. The primary objective was to evaluate the applicability of the HTS glove in patients with SSc by comparing its parameters (touch duration [TD], intertapping interval [ITI], and movement rate [MR]) with healthy controls (HCs). The assumptions were that HTS parameters would be significantly impaired in patients with SSc and would correlate with clinical, imaging, and patient-reported outcome measures (PROMs).

Methods: A cross-sectional study was conducted enrolling 25 patients with SSc (fulfilling 2013 American College of Rheumatology/EULAR criteria) and 25 matched HCs. The main outcome variables were the HTS glove parameters. All participants also underwent grip strength measurement and an assessment of PROMs (Scleroderma Health Assessment Questionnaire and Duruöz Hand Index), together with a performance-based evaluation of hand mobility using the Hand Mobility in Scleroderma test. Clinical and imaging data were collected for patients with SSc including the modified Rodnan skin score (mRSS) and high-frequency skin ultrasonography (HFSU) to measure hand and total body dermal thickness.

Results: Patients with SSc performed finger movements significantly more slowly and less efficiently than HCs, demonstrated by prolonged mean TD and ITI and reduced MR (P < 0.05 for all). In patients with SSc, HTS parameters significantly correlated with poorer PROMs (0.39 < r < 0.65, all P < 0.01 for all). Notably, both mean TD and ITI directly correlated with the mRSS (0.40 < r < 0.48, all P < 0.05). Furthermore, the mean TD showed a significant direct correlation with HFSU-measured dermal thickness of the dorsum of the hands and with total body dermal thickness (P < 0.05 for all). No significant differences in HTS parameters were detected based on nailfold videocapillaroscopy findings or organ involvement.

Conclusion: The HTS glove provides objective measures of the impaired hand dexterity in SSc. The significant correlations between HTS parameters, PROMs, mRSS, and HFSU-measured dermal thickness suggest a significant relationship between skin fibrosis and functional hand disability. The HTS glove seems a promising tool for objectively monitoring SSc hand outcomes, and studies to explore its utility in monitoring therapeutic responses are in progression.

一种用于客观评估系统性硬化症患者手灵活性的工程手套。
目的:手部残疾是系统性硬化症(SSc)中主要的肌肉骨骼功能损害,但其客观评估仍然具有挑战性。经过验证的手部测试系统(HTS)工程手套为风湿病患者提供了定量灵巧性数据。主要目的是通过将HTS手套的参数(触摸持续时间[TD]、间隔时间[ITI]和运动速率[MR])与健康对照(hc)进行比较,评估HTS手套在SSc患者中的适用性。假设SSc患者的HTS参数会显著受损,并与临床、影像学和患者报告的结果测量(PROMs)相关。方法:一项横断面研究纳入了25例SSc患者(符合2013年美国风湿病学会/EULAR标准)和25例匹配的hc。主要结局变量为HTS手套参数。所有参与者还接受了握力测量和PROMs(硬皮病健康评估问卷和Duruöz手部指数)评估,以及使用硬皮病手部活动能力测试对手部活动能力进行基于性能的评估。收集SSc患者的临床和影像学资料,包括改良罗德曼皮肤评分(mRSS)和高频皮肤超声(HFSU)测量手部和全身皮肤厚度。结果:SSc患者的手指运动明显慢于hcc患者,且效率较低,表现为平均TD和ITI延长,MR降低(均P < 0.05)。SSc患者HTS参数与较差的PROMs显著相关(0.39 < r < 0.65, P均< 0.01)。值得注意的是,平均TD和ITI与mRSS直接相关(0.40 < r < 0.48,均P < 0.05)。此外,平均TD与hfsu测量的手背皮肤厚度和全身皮肤厚度有显著的直接相关性(P < 0.05)。甲襞视频毛细血管镜检查结果或器官受累的HTS参数无显著差异。结论:HTS手套是衡量SSc手部灵巧性受损的客观指标。HTS参数、PROMs、mRSS和hfsu测量的皮肤厚度之间存在显著相关性,表明皮肤纤维化与功能性手残疾之间存在显著关系。HTS手套似乎是客观监测SSc手部结果的有前途的工具,探索其在监测治疗反应方面的效用的研究正在进行中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书