Echocardiography-guided assessment of mouse cardiac transplant rejection improves model reproducibility.

Frontiers in transplantation Pub Date : 2026-06-17 eCollection Date: 2026-01-01 DOI:10.3389/frtra.2026.1840060
Angela Clemens, Sara Alibrandi, Paolo Molinari, Johan Noble, Barbara Franchin, Miguel Fribourg, Paolo Cravedi, Nicholas Chun
{"title":"Echocardiography-guided assessment of mouse cardiac transplant rejection improves model reproducibility.","authors":"Angela Clemens, Sara Alibrandi, Paolo Molinari, Johan Noble, Barbara Franchin, Miguel Fribourg, Paolo Cravedi, Nicholas Chun","doi":"10.3389/frtra.2026.1840060","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The mouse heterotopic heart transplant model is a widely used system for dissecting mechanisms of graft rejection and identifying new therapeutic targets, owing to its relative technical simplicity and the availability of well-defined inbred strains. One limitation of the model is that monitoring of the non-life sustaining implanted graft by manual palpation does not provide information regarding the magnitude of the anti-donor immune response and is operator-dependent. Building on previous studies suggesting that trans-abdominal ultrasonography can detect graft rejection more precisely than manual palpation, we tested if changes in motion mode (M-mode) ultrasound also correlated with the magnitude of the anti-donor T cell response.</p><p><strong>Methods: </strong>We performed sets of MHC-mismatched heterotopic heart transplants in mice and quantified the accuracy of palpation vs. ultrasonography in determining graft rejection. In an additional set of mice, we performed mixed lymphocyte reactions to quantify anti-donor T cell immunity at a fixed time point (usual experimental design) or at time points determined by changes in allograft M-mode analysis.</p><p><strong>Conclusions: </strong>The data demonstrate that ultrasonography is superior to manual palpation for determining graft rejection and newly shows that changes in M-mode associate with the magnitude of anti-donor T cell immunity. These findings are important to increase reproducibility and translational impact of studies using this model.</p>","PeriodicalId":519976,"journal":{"name":"Frontiers in transplantation","volume":"5 ","pages":"1840060"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13318921/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in transplantation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/frtra.2026.1840060","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The mouse heterotopic heart transplant model is a widely used system for dissecting mechanisms of graft rejection and identifying new therapeutic targets, owing to its relative technical simplicity and the availability of well-defined inbred strains. One limitation of the model is that monitoring of the non-life sustaining implanted graft by manual palpation does not provide information regarding the magnitude of the anti-donor immune response and is operator-dependent. Building on previous studies suggesting that trans-abdominal ultrasonography can detect graft rejection more precisely than manual palpation, we tested if changes in motion mode (M-mode) ultrasound also correlated with the magnitude of the anti-donor T cell response.

Methods: We performed sets of MHC-mismatched heterotopic heart transplants in mice and quantified the accuracy of palpation vs. ultrasonography in determining graft rejection. In an additional set of mice, we performed mixed lymphocyte reactions to quantify anti-donor T cell immunity at a fixed time point (usual experimental design) or at time points determined by changes in allograft M-mode analysis.

Conclusions: The data demonstrate that ultrasonography is superior to manual palpation for determining graft rejection and newly shows that changes in M-mode associate with the magnitude of anti-donor T cell immunity. These findings are important to increase reproducibility and translational impact of studies using this model.

超声心动图引导的小鼠心脏移植排斥反应评估提高了模型的可重复性。
背景:小鼠异位心脏移植模型由于其相对简单的技术和良好定义的近交系的可用性,被广泛用于解剖移植排斥机制和确定新的治疗靶点。该模型的一个局限性是,通过人工触诊监测非维持生命的植入移植物不能提供有关抗供体免疫反应大小的信息,并且依赖于操作者。基于先前的研究表明,经腹超声检查可以比手工触诊更精确地检测移植排斥反应,我们测试了运动模式(m模式)超声的变化是否也与抗供体T细胞反应的大小相关。方法:我们在小鼠身上进行了几组mhc不匹配的异位心脏移植,并量化了触诊和超声检查在确定移植排斥反应方面的准确性。在另一组小鼠中,我们进行了混合淋巴细胞反应,以在固定时间点(通常的实验设计)或由同种异体移植m模式分析的变化确定的时间点量化抗供体T细胞免疫。结论:超声检查在判断移植排斥反应方面优于手工触诊,并显示m模式的变化与抗供体T细胞免疫的大小有关。这些发现对于提高使用该模型的研究的可重复性和转化影响具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书