A Comprehensive Guide to Tibial Nailing Systems for Short Segment Nailing Procedures.

IF 2 3区 医学 Q3 ORTHOPEDICS
Youssef M Khalafallah, Beatrice A Morrow, Douglas R Dirschl
{"title":"A Comprehensive Guide to Tibial Nailing Systems for Short Segment Nailing Procedures.","authors":"Youssef M Khalafallah, Beatrice A Morrow, Douglas R Dirschl","doi":"10.1097/BOT.0000000000003239","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To characterize and compare interlocking screw configurations and design specifications of commercially available tibial intramedullary nail systems used for short segment fixation.</p><p><strong>Methods: </strong>Data were collected in November 2025 from publicly available product information on manufacturer websites for tibial intramedullary nail systems marketed in the United States. Manufactures were identified based on established presence in the United States orthopedic implant market, including vendors listed at the 2025 Orthopaedic Trauma Association annual meeting. When required information was not publicly available, additional details were obtained through direct communication with manufacturer representatives via email correspondence and product specialists. Tibial nail systems were included if they were actively marketed and available for clinical use in the United States at the time of data collection. For each system, data were collected on interlocking screw hole quantity and position, nail diameter, total length, and relavant design features.</p><p><strong>Results: </strong>Thirteen tibial nailing systems were identified from ten manufacturers were identified and analyzed. Interlocking screw configurations varied across systems, with 3 to 5 proximal screws and 3 to 5 distal screws available, as well as differences in screw number and spatial distribution. Nail diameters, available lengths, and additional design features also varied among systems. The shortest proximal distance from the nail tip to the center of the second interlocking screw hole was 17mm and the shortest distal distance was 12mm.</p><p><strong>Conclusions: </strong>This study provided a detail comparison of tibial nailing systems available in the United States, offering valuable information on nail specifications and screw positions. A comprehensive table and graphic representation serves as a practical planning resource for surgeons in the operative management of short segment distal tibial fractures, enhancing the selection of optimal implants for personalized patient care.</p><p><strong>Level of evidence: </strong>V.</p>","PeriodicalId":16644,"journal":{"name":"Journal of Orthopaedic Trauma","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Trauma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BOT.0000000000003239","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To characterize and compare interlocking screw configurations and design specifications of commercially available tibial intramedullary nail systems used for short segment fixation.

Methods: Data were collected in November 2025 from publicly available product information on manufacturer websites for tibial intramedullary nail systems marketed in the United States. Manufactures were identified based on established presence in the United States orthopedic implant market, including vendors listed at the 2025 Orthopaedic Trauma Association annual meeting. When required information was not publicly available, additional details were obtained through direct communication with manufacturer representatives via email correspondence and product specialists. Tibial nail systems were included if they were actively marketed and available for clinical use in the United States at the time of data collection. For each system, data were collected on interlocking screw hole quantity and position, nail diameter, total length, and relavant design features.

Results: Thirteen tibial nailing systems were identified from ten manufacturers were identified and analyzed. Interlocking screw configurations varied across systems, with 3 to 5 proximal screws and 3 to 5 distal screws available, as well as differences in screw number and spatial distribution. Nail diameters, available lengths, and additional design features also varied among systems. The shortest proximal distance from the nail tip to the center of the second interlocking screw hole was 17mm and the shortest distal distance was 12mm.

Conclusions: This study provided a detail comparison of tibial nailing systems available in the United States, offering valuable information on nail specifications and screw positions. A comprehensive table and graphic representation serves as a practical planning resource for surgeons in the operative management of short segment distal tibial fractures, enhancing the selection of optimal implants for personalized patient care.

Level of evidence: V.

胫骨短节段钉入系统综合指南。
目的:描述和比较市售的用于短节段固定的胫骨髓内钉系统的互锁螺钉配置和设计规格。方法:数据于2025年11月从美国上市的胫骨髓内钉系统的制造商网站上公开的产品信息中收集。制造商是根据在美国骨科植入物市场的现有存在来确定的,包括在2025年骨科创伤协会年会上列出的供应商。当需要的信息不公开时,通过电子邮件通信和产品专家与制造商代表直接沟通,获得额外的细节。在数据收集时,如果胫骨钉系统在美国积极销售并可用于临床使用,则将其包括在内。对于每个系统,收集了联锁螺钉孔的数量和位置、钉径、总长度和相关设计特征的数据。结果:从10家生产厂家中鉴定出13种胫骨钉系统。不同系统的联锁螺钉配置各不相同,有3 - 5个近端螺钉和3 - 5个远端螺钉,螺钉数量和空间分布也有所不同。钉直径、可用长度和其他设计特征也因系统而异。钉尖至第二联锁螺钉孔中心的近端距离为17mm,远端距离为12mm。结论:本研究提供了美国现有胫骨钉系统的详细比较,提供了有关钉规格和螺钉位置的宝贵信息。全面的表格和图形表示为外科医生在短段胫骨远端骨折的手术管理中提供了实用的规划资源,增强了最佳植入物的选择,以实现个性化的患者护理。证据等级:V。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orthopaedic Trauma
Journal of Orthopaedic Trauma 医学-运动科学
CiteScore
3.90
自引率
8.70%
发文量
396
审稿时长
3-8 weeks
期刊介绍: Journal of Orthopaedic Trauma is devoted exclusively to the diagnosis and management of hard and soft tissue trauma, including injuries to bone, muscle, ligament, and tendons, as well as spinal cord injuries. Under the guidance of a distinguished international board of editors, the journal provides the most current information on diagnostic techniques, new and improved surgical instruments and procedures, surgical implants and prosthetic devices, bioplastics and biometals; and physical therapy and rehabilitation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书