Publication Guidelines for Optimized Multiparameter Immunolabeling Panels (OMIPs)

IF 2.9 4区 生物学 Q3 BIOCHEMICAL RESEARCH METHODS
Cytometry Part A Pub Date : 2026-07-29 Epub Date: 2026-07-01 DOI:10.1002/cyto.a.70045
Antonio Cosma, Tess M. Brodie, Andrew Filby, Maria C. Jaimes, Raluca A. Niesner, Alfonso J. Schmidt, Yolanda D. Mahnke
{"title":"Publication Guidelines for Optimized Multiparameter Immunolabeling Panels (OMIPs)","authors":"Antonio Cosma,&nbsp;Tess M. Brodie,&nbsp;Andrew Filby,&nbsp;Maria C. Jaimes,&nbsp;Raluca A. Niesner,&nbsp;Alfonso J. Schmidt,&nbsp;Yolanda D. Mahnke","doi":"10.1002/cyto.a.70045","DOIUrl":null,"url":null,"abstract":"<p>Those with a keen eye will immediately notice a “mistake” in the title. The expected term Optimized Multicolor Immunofluorescence Panel has been replaced with Optimized Multiparameter Immunolabeling Panel, while retaining the familiar acronym OMIP. This change clarifies that OMIPs encompass panels for technologies that use fluorescence, as they have since 2010, other optical emissions such as those used in intravital multiphoton microscopy, and mass cytometry, as they have since 2017. OMIPs may also include other methods of labeling molecules, such as genetically encoded fluorochromes and dyes, and the measured parameters may include endogenous fluorescence, such as that of NAD(P)H. These panels typically include at least a few labeled antibodies (Abs) used to detect their target molecules. The new name is therefore appropriate for all such panels.</p><p>When OMIPs were first introduced in 2010, primarily with flow cytometry in mind, the highest multiplexing achievable with conventional flow cytometry (CFC) was 18 distinct fluorochromes [<span>1</span>]. Mass cytometry (MC), which enables multiplexing beyond 30 parameters, was adopted more widely in the years that followed. The field has since advanced to the point where 60+ fluorescent parameters can be measured with spectral flow cytometry (SFC), and higher levels of multiplexing are likely to emerge. This progress has driven a new wave of fluorochrome design aimed at narrowing excitation and emission windows to reduce spillover-spreading between reagents. These tools are crucial for building reliable high-parameter panels, but the task remains far from trivial. OMIPs are therefore increasingly important for sharing optimized panels with the research community and for communicating the advantages and limitations of different procedures, protocols, and reagent combinations. They have also proven relevant in veterinary applications, where even small panels can be challenging because of limited species-specific resources. All existing OMIPs can be queried in a database developed and maintained by Antonio Cosma and colleagues, available via the ISAC website.\n <sup>1</sup>\n \n </p><p>OMIPs have been adopted beyond CFC and now include panels for MC, SFC, and imaging mass cytometry (IMC) (Graphic 1). They will hopefully soon also feature panels for imaging flow cytometry (IFC), fluorescence microscopy (FM), and intravital microscopy (IVM), as well as panels used for clinical applications. Although the original OMIP publication guidelines remain valid [<span>1</span>], authors who submit panels for these different technologies and applications require more specific guidance. In addition, the full OMIP will henceforth be published as a single document within the printed journal. OMIPs were initially designed to consist of a brief section presenting the panel in the printed journal and a more elaborate online section presenting the technical details and discussion of optimization procedures. The online material, which represents the core technical content of an OMIP, cannot be indexed and queried in the same manner as regular journal content, which has proven unsatisfactory. The present document therefore provides renewed and expanded guidelines that incorporate all changes and developments since the introduction of OMIPs.</p><p>The present document covers requirements specific to OMIP submissions, and elements that have repeatedly raised questions in the past. For general topics not addressed here, including statistical reporting, data analysis presentation, manuscript formatting, ethical compliance, and the peer-review process, consult the general author guidelines for <i>Cytometry Part A</i>.\n <sup>2</sup>\n Where the general author guidelines and the present OMIP guidelines overlap, the OMIP guidelines take precedence for OMIP-specific elements.</p><p>The basic OMIP qualifiers remain largely unchanged and are reproduced here, with some adjustments and additional explanations, from the original OMIP guidelines [<span>1</span>].</p><p>The <i>Panel Presentation</i> section should be concise.</p><p>The <i>Technical Information</i> section should present all pertinent information required to reproduce the panel and the reported results. This includes the instrumentation, reagents, and protocol used to achieve the reported panel performance. Any tables should support important technical aspects of the panel or instrumentation and be clearly discussed in the manuscript.</p><p>It is important to distinguish between panel design and panel optimization. Panel design uses available knowledge, tools, reagent availability, and prior experience to generate a panel expected to perform well. Panel optimization, in contrast, empirically evaluates and improves marker resolution, identifies and eliminates unwanted reagent interactions, and assesses the accuracy of observed staining patterns under the actual staining and acquisition conditions. Mathematical, statistical, and computational tools may support both phases. However, their utility depends on the context in which they are applied and on the type of input data used. For example, models based on theoretical inputs, such as spectra from spectral libraries, can guide initial panel design but do not account for all assay-specific variables, including reagent performance, sample autofluorescence, staining conditions, instrument configuration, biological expression patterns, or spectral modulations exerted by buffers. Models based on measured inputs, such as single-stained controls acquired under the same experimental conditions, provide stronger evidence for panel optimization, but do not replace empirical assessment of the fully stained panel. A panel generated by theoretical or computational design alone, even when it appears suitable for its intended purpose, is therefore insufficient for an OMIP. Rather, such a panel represents only the starting point for the optimization procedures required to establish its empirical performance.</p><p>The <i>Panel Design and Optimization</i> section should be the most comprehensive part of the manuscript, reflecting the complex and iterative process required to develop an optimized panel. Balance completeness with focus, and ensure that the description includes all key steps needed to justify the final panel arrangement and optimization decisions.</p><p>Where mathematical, statistical, or computational methods are applied for panel design or optimization, report them in sufficient detail to permit independent evaluation. Specify the objective function, input data, assumptions, constraints, parameter settings, and decision criteria. Use conventional terminology for established mathematical concepts, statistics, or metrics and avoid proprietary or idiosyncratic names when a standard term is available [<span>12</span>]. Use transparent notation that allows readers to reconstruct the underlying equations or calculations. Do not use methods that are undisclosed, constitute a trade secret, or are otherwise insufficiently described as the sole basis for panel design or optimization. If a method is described in a published patent application, patent, software documentation, or other accessible source, cite that source and explain how the method was applied in the OMIP. If a new metric, objective function, or optimization algorithm is used, define and characterize it fully, including its mathematical formulation, rationale, inputs, parameters, interpretation, limitations, and role in the panel-design decision process. Avoid introducing new evaluation metrics in an OMIP unless they are essential to the panel design and can be described completely. Instead, introduce and validate substantial new metrics or optimization strategies in a separate methodological publication.</p><p>This section is particularly important for clinical panels but may also be relevant for research panels.</p><p>Determine the appropriate level of validation according to the intended application of the panel as outlined in CLSI (Clinical and Laboratory Standards Institute) H62 [<span>19</span>]. Table 22 of CLSI H62 specifically identifies validation scenarios based on intended use, helping researchers formulate an appropriate validation plan for their assay. Detailed practical guidance for defining acceptance criteria, complementary to CLSI H62, is provided in the five-part practice guidelines series published by the International Council for Standardization of Hematology (ICSH) in collaboration with the International Clinical Cytometry Society (ICCS) [<span>20-24</span>].</p><p>Explicitly state the chosen validation framework, acceptance criteria, and key readouts used to evaluate panel performance. Demonstrate and discuss the validation procedures and results accordingly. Common validation parameters include, but are not limited to, sample stability, post-staining stability, precision or reproducibility, sensitivity, and specificity.</p><p>Where small panel modifications are planned to accommodate rare patient phenotypes [<span>25</span>], provide appropriate information and data in a separate section. If the panel edits are substantial, the editor may recommend their presentation in a separate publication. In either case, optimization and validation [<span>26</span>] need to be demonstrated.</p><p>Conclude each manuscript with a <i>Data Availability Statement</i> that provides the digital object identifier (DOI), accession number, or other persistent identifier for a permanent online repository and specifies which data have been deposited. Use an appropriate public data repository consistent with the general author guidelines for <i>Cytometry Part A</i>.\n <sup>2</sup>\n \n </p><p>Authors should include, where applicable, representative data, single-stained controls, and biological controls. Data files used to generate Figure 1 must be provided. If the manuscript claims that the panel is applicable to other tissues, animal strains or species, or disease states, the supporting data files must also be included. For each dataset, provide raw data, where available, as well as compensated or unmixed versions, together with the corresponding compensation or unmixing matrix. Provide these data for peer review and to allow readers to examine the panel in greater depth, particularly when considering whether to adopt an OMIP for their own studies. A statement that data are available only “upon reasonable request” is not acceptable. OMIP data must be publicly available as a condition of acceptance.</p><p>Annotate data files with descriptive file names and correct metadata so that they are easy to identify, and accompany them, where possible, with a data-analysis workspace containing all gating and other pertinent analyses. Where applicable, include associated coding scripts, masks, and feature tables.</p><p>If an OMIP is based on, or includes, clinical or patient-derived data, obtain formal verification from the institutional data officer, compliance office, or ethics committee before deposition, confirming that all applicable data-protection, de-identification, and sharing requirements have been met. Fully de-identify all shared datasets in accordance with applicable institutional, national, and international standards, such as HIPAA, GDPR, or equivalent frameworks [<span>27, 28</span>]. Deposit de-identified clinical datasets in repositories that provide controlled-access mechanisms and enforce appropriate data-use agreements, such as the Immunology Database and Analysis Portal (ImmPort [<span>29</span>]), the Database of Genotypes and Phenotypes (dbGaP [<span>30</span>]), or the European Genome-phenome Archive (EGA) [<span>31</span>]. Specify the repository name, accession number, access type (such as controlled, registered, or embargoed), and any applicable data-use conditions in the manuscript. Use open-access repositories for human-derived data only when explicitly approved by the relevant institutional data-governance office.</p><p>Include a reference list of relevant literature at the end of the manuscript, including all OMIPs cited in Table 1 and in the <i>Similarity to Published OMIPs</i> section.</p><p>Finally, include a completed Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) form with each OMIP submission as supplemental material on the publisher's website [<span>32</span>].</p><p>\n <b>Antonio Cosma:</b> writing – review and editing. <b>Tess M. Brodie:</b> writing – review and editing. <b>Andrew Filby:</b> writing – review and editing. <b>Maria C. Jaimes:</b> writing – review and editing. <b>Raluca A. Niesner:</b> writing – review and editing. <b>Alfonso J. Schmidt:</b> writing – review and editing. <b>Yolanda D. Mahnke:</b> writing – review and editing, visualization, writing – original draft, project administration, conceptualization.</p><p>The authors acknowledge the Hugh Green Foundation for their support and funding of AJS at the Hugh Green Technology Centre at the Malaghan Institute of Medical Research, as well as the German Research Foundation for grants CRC1444 and NI1167/9-1 to RN.</p><p>\n A.F. is on the Scientific Advisory Board of Zomp. All other authors declare no conflicts of interest.\n </p>","PeriodicalId":11068,"journal":{"name":"Cytometry Part A","volume":"109 7","pages":"465-481"},"PeriodicalIF":2.9000,"publicationDate":"2026-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cyto.a.70045","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cytometry Part A","FirstCategoryId":"99","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cyto.a.70045","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Those with a keen eye will immediately notice a “mistake” in the title. The expected term Optimized Multicolor Immunofluorescence Panel has been replaced with Optimized Multiparameter Immunolabeling Panel, while retaining the familiar acronym OMIP. This change clarifies that OMIPs encompass panels for technologies that use fluorescence, as they have since 2010, other optical emissions such as those used in intravital multiphoton microscopy, and mass cytometry, as they have since 2017. OMIPs may also include other methods of labeling molecules, such as genetically encoded fluorochromes and dyes, and the measured parameters may include endogenous fluorescence, such as that of NAD(P)H. These panels typically include at least a few labeled antibodies (Abs) used to detect their target molecules. The new name is therefore appropriate for all such panels.

When OMIPs were first introduced in 2010, primarily with flow cytometry in mind, the highest multiplexing achievable with conventional flow cytometry (CFC) was 18 distinct fluorochromes [1]. Mass cytometry (MC), which enables multiplexing beyond 30 parameters, was adopted more widely in the years that followed. The field has since advanced to the point where 60+ fluorescent parameters can be measured with spectral flow cytometry (SFC), and higher levels of multiplexing are likely to emerge. This progress has driven a new wave of fluorochrome design aimed at narrowing excitation and emission windows to reduce spillover-spreading between reagents. These tools are crucial for building reliable high-parameter panels, but the task remains far from trivial. OMIPs are therefore increasingly important for sharing optimized panels with the research community and for communicating the advantages and limitations of different procedures, protocols, and reagent combinations. They have also proven relevant in veterinary applications, where even small panels can be challenging because of limited species-specific resources. All existing OMIPs can be queried in a database developed and maintained by Antonio Cosma and colleagues, available via the ISAC website. 1

OMIPs have been adopted beyond CFC and now include panels for MC, SFC, and imaging mass cytometry (IMC) (Graphic 1). They will hopefully soon also feature panels for imaging flow cytometry (IFC), fluorescence microscopy (FM), and intravital microscopy (IVM), as well as panels used for clinical applications. Although the original OMIP publication guidelines remain valid [1], authors who submit panels for these different technologies and applications require more specific guidance. In addition, the full OMIP will henceforth be published as a single document within the printed journal. OMIPs were initially designed to consist of a brief section presenting the panel in the printed journal and a more elaborate online section presenting the technical details and discussion of optimization procedures. The online material, which represents the core technical content of an OMIP, cannot be indexed and queried in the same manner as regular journal content, which has proven unsatisfactory. The present document therefore provides renewed and expanded guidelines that incorporate all changes and developments since the introduction of OMIPs.

The present document covers requirements specific to OMIP submissions, and elements that have repeatedly raised questions in the past. For general topics not addressed here, including statistical reporting, data analysis presentation, manuscript formatting, ethical compliance, and the peer-review process, consult the general author guidelines for Cytometry Part A. 2 Where the general author guidelines and the present OMIP guidelines overlap, the OMIP guidelines take precedence for OMIP-specific elements.

The basic OMIP qualifiers remain largely unchanged and are reproduced here, with some adjustments and additional explanations, from the original OMIP guidelines [1].

The Panel Presentation section should be concise.

The Technical Information section should present all pertinent information required to reproduce the panel and the reported results. This includes the instrumentation, reagents, and protocol used to achieve the reported panel performance. Any tables should support important technical aspects of the panel or instrumentation and be clearly discussed in the manuscript.

It is important to distinguish between panel design and panel optimization. Panel design uses available knowledge, tools, reagent availability, and prior experience to generate a panel expected to perform well. Panel optimization, in contrast, empirically evaluates and improves marker resolution, identifies and eliminates unwanted reagent interactions, and assesses the accuracy of observed staining patterns under the actual staining and acquisition conditions. Mathematical, statistical, and computational tools may support both phases. However, their utility depends on the context in which they are applied and on the type of input data used. For example, models based on theoretical inputs, such as spectra from spectral libraries, can guide initial panel design but do not account for all assay-specific variables, including reagent performance, sample autofluorescence, staining conditions, instrument configuration, biological expression patterns, or spectral modulations exerted by buffers. Models based on measured inputs, such as single-stained controls acquired under the same experimental conditions, provide stronger evidence for panel optimization, but do not replace empirical assessment of the fully stained panel. A panel generated by theoretical or computational design alone, even when it appears suitable for its intended purpose, is therefore insufficient for an OMIP. Rather, such a panel represents only the starting point for the optimization procedures required to establish its empirical performance.

The Panel Design and Optimization section should be the most comprehensive part of the manuscript, reflecting the complex and iterative process required to develop an optimized panel. Balance completeness with focus, and ensure that the description includes all key steps needed to justify the final panel arrangement and optimization decisions.

Where mathematical, statistical, or computational methods are applied for panel design or optimization, report them in sufficient detail to permit independent evaluation. Specify the objective function, input data, assumptions, constraints, parameter settings, and decision criteria. Use conventional terminology for established mathematical concepts, statistics, or metrics and avoid proprietary or idiosyncratic names when a standard term is available [12]. Use transparent notation that allows readers to reconstruct the underlying equations or calculations. Do not use methods that are undisclosed, constitute a trade secret, or are otherwise insufficiently described as the sole basis for panel design or optimization. If a method is described in a published patent application, patent, software documentation, or other accessible source, cite that source and explain how the method was applied in the OMIP. If a new metric, objective function, or optimization algorithm is used, define and characterize it fully, including its mathematical formulation, rationale, inputs, parameters, interpretation, limitations, and role in the panel-design decision process. Avoid introducing new evaluation metrics in an OMIP unless they are essential to the panel design and can be described completely. Instead, introduce and validate substantial new metrics or optimization strategies in a separate methodological publication.

This section is particularly important for clinical panels but may also be relevant for research panels.

Determine the appropriate level of validation according to the intended application of the panel as outlined in CLSI (Clinical and Laboratory Standards Institute) H62 [19]. Table 22 of CLSI H62 specifically identifies validation scenarios based on intended use, helping researchers formulate an appropriate validation plan for their assay. Detailed practical guidance for defining acceptance criteria, complementary to CLSI H62, is provided in the five-part practice guidelines series published by the International Council for Standardization of Hematology (ICSH) in collaboration with the International Clinical Cytometry Society (ICCS) [20-24].

Explicitly state the chosen validation framework, acceptance criteria, and key readouts used to evaluate panel performance. Demonstrate and discuss the validation procedures and results accordingly. Common validation parameters include, but are not limited to, sample stability, post-staining stability, precision or reproducibility, sensitivity, and specificity.

Where small panel modifications are planned to accommodate rare patient phenotypes [25], provide appropriate information and data in a separate section. If the panel edits are substantial, the editor may recommend their presentation in a separate publication. In either case, optimization and validation [26] need to be demonstrated.

Conclude each manuscript with a Data Availability Statement that provides the digital object identifier (DOI), accession number, or other persistent identifier for a permanent online repository and specifies which data have been deposited. Use an appropriate public data repository consistent with the general author guidelines for Cytometry Part A. 2

Authors should include, where applicable, representative data, single-stained controls, and biological controls. Data files used to generate Figure 1 must be provided. If the manuscript claims that the panel is applicable to other tissues, animal strains or species, or disease states, the supporting data files must also be included. For each dataset, provide raw data, where available, as well as compensated or unmixed versions, together with the corresponding compensation or unmixing matrix. Provide these data for peer review and to allow readers to examine the panel in greater depth, particularly when considering whether to adopt an OMIP for their own studies. A statement that data are available only “upon reasonable request” is not acceptable. OMIP data must be publicly available as a condition of acceptance.

Annotate data files with descriptive file names and correct metadata so that they are easy to identify, and accompany them, where possible, with a data-analysis workspace containing all gating and other pertinent analyses. Where applicable, include associated coding scripts, masks, and feature tables.

If an OMIP is based on, or includes, clinical or patient-derived data, obtain formal verification from the institutional data officer, compliance office, or ethics committee before deposition, confirming that all applicable data-protection, de-identification, and sharing requirements have been met. Fully de-identify all shared datasets in accordance with applicable institutional, national, and international standards, such as HIPAA, GDPR, or equivalent frameworks [27, 28]. Deposit de-identified clinical datasets in repositories that provide controlled-access mechanisms and enforce appropriate data-use agreements, such as the Immunology Database and Analysis Portal (ImmPort [29]), the Database of Genotypes and Phenotypes (dbGaP [30]), or the European Genome-phenome Archive (EGA) [31]. Specify the repository name, accession number, access type (such as controlled, registered, or embargoed), and any applicable data-use conditions in the manuscript. Use open-access repositories for human-derived data only when explicitly approved by the relevant institutional data-governance office.

Include a reference list of relevant literature at the end of the manuscript, including all OMIPs cited in Table 1 and in the Similarity to Published OMIPs section.

Finally, include a completed Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) form with each OMIP submission as supplemental material on the publisher's website [32].

Antonio Cosma: writing – review and editing. Tess M. Brodie: writing – review and editing. Andrew Filby: writing – review and editing. Maria C. Jaimes: writing – review and editing. Raluca A. Niesner: writing – review and editing. Alfonso J. Schmidt: writing – review and editing. Yolanda D. Mahnke: writing – review and editing, visualization, writing – original draft, project administration, conceptualization.

The authors acknowledge the Hugh Green Foundation for their support and funding of AJS at the Hugh Green Technology Centre at the Malaghan Institute of Medical Research, as well as the German Research Foundation for grants CRC1444 and NI1167/9-1 to RN.

A.F. is on the Scientific Advisory Board of Zomp. All other authors declare no conflicts of interest.

Abstract Image

优化的多参数免疫标记小组(omip)的出版指南。
目光敏锐的人会立刻发现标题中的“错误”。预期的术语“优化多色免疫荧光面板”已被“优化多参数免疫标记面板”所取代,同时保留了熟悉的首字母缩略词OMIP。这一变化澄清了omip包括自2010年以来使用荧光技术的面板,以及自2017年以来用于活体多光子显微镜和质量细胞术的其他光学发射面板。omip还可以包括其他标记分子的方法,如基因编码的荧光染料和染料,测量的参数可以包括内源性荧光,如NAD(P)H的荧光。这些面板通常包括至少几个标记抗体(Abs),用于检测其目标分子。因此,新名称适用于所有此类面板。当omip于2010年首次引入时,主要考虑到流式细胞术,传统流式细胞术(CFC)可实现的最高复用率为18个不同的荧光色[1]。质量细胞术(MC)能够实现超过30个参数的多路复用,在随后的几年里得到了更广泛的采用。该领域已经发展到可以用光谱流式细胞术(SFC)测量60多个荧光参数,并且可能出现更高水平的多路复用。这一进展推动了一波新的荧光染料设计,旨在缩小激发和发射窗口,以减少试剂之间的溢出扩散。这些工具对于构建可靠的高参数面板至关重要,但这项任务远非微不足道。因此,omip对于与研究界共享优化面板以及交流不同程序、协议和试剂组合的优点和局限性越来越重要。它们也被证明与兽医应用相关,在兽医应用中,由于特定物种的资源有限,即使是很小的面板也可能具有挑战性。所有现有的omip都可以在由Antonio Cosma及其同事开发和维护的数据库中查询,该数据库可通过ISAC网站获得。除CFC外,现已采用omip,包括用于MC、SFC和成像细胞计数(IMC)的面板(图1)。他们希望很快还能有成像流式细胞术(IFC)、荧光显微镜(FM)和活体显微镜(IVM)的面板,以及用于临床应用的面板。尽管最初的OMIP出版指南仍然有效,但为这些不同的技术和应用程序提交面板的作者需要更具体的指导。此外,OMIP全文今后将作为单一文件在印刷的期刊内出版。omip最初的设计包括在印刷期刊上介绍小组的简短部分和更详细的在线部分,介绍技术细节和优化程序的讨论。作为OMIP核心技术内容的在线资料,不能像常规期刊内容那样进行索引和查询,这已被证明是令人不满意的。因此,本文件提供了更新和扩大的准则,其中包括自采用管理方案以来的所有变化和发展。本文件包括OMIP提交的具体要求,以及过去一再提出问题的要素。对于本文未涉及的一般主题,包括统计报告、数据分析呈现、手稿格式、伦理合规性和同行评议过程,请参考《细胞术》第a部分的一般作者指南。2当一般作者指南和本OMIP指南重叠时,OMIP指南优先适用于OMIP特定元素。基本的OMIP限定符基本保持不变,本文从原始的OMIP指南[1]中复制,并进行了一些调整和额外的解释。小组报告部分应该简明扼要。技术信息部分应提供复制专家组和报告结果所需的所有相关信息。这包括仪器,试剂和方案,用于实现报告的面板性能。任何表格都应支持面板或仪器的重要技术方面,并在手稿中明确讨论。区分面板设计和面板优化是很重要的。面板设计使用可用的知识、工具、试剂可用性和先前的经验来生成预期性能良好的面板。相比之下,面板优化是经验性地评估和提高标记分辨率,识别和消除不必要的试剂相互作用,并评估在实际染色和获取条件下观察到的染色模式的准确性。数学、统计和计算工具可以支持这两个阶段。 但是,它们的效用取决于应用它们的上下文和所使用的输入数据的类型。例如,基于理论输入的模型,例如来自光谱库的光谱,可以指导初始面板设计,但不能解释所有分析特定变量,包括试剂性能、样品自身荧光、染色条件、仪器配置、生物表达模式或缓冲液施加的光谱调制。基于测量输入的模型,例如在相同实验条件下获得的单染色对照,为面板优化提供了更有力的证据,但不能取代对完全染色面板的经验评估。因此,仅由理论或计算设计生成的面板,即使看起来适合其预期目的,也不足以用于OMIP。相反,这样的面板只代表了建立其经验性能所需的优化程序的起点。面板设计和优化部分应该是手稿中最全面的部分,反映了开发优化面板所需的复杂和迭代过程。平衡完整性和重点,并确保描述包括证明最终面板安排和优化决策所需的所有关键步骤。当应用数学、统计或计算方法进行面板设计或优化时,应充分详细地报告,以便进行独立评估。指定目标函数、输入数据、假设、约束、参数设置和决策标准。对于已建立的数学概念、统计数据或度量使用常规术语,当有标准术语可用时,避免使用专有或特殊的名称。使用透明的符号,允许读者重建底层方程或计算。不要使用未公开的、构成商业秘密的或未被充分描述为面板设计或优化的唯一依据的方法。如果在公开的专利申请、专利、软件文档或其他可访问的来源中描述了一种方法,请引用该来源并解释该方法如何在OMIP中应用。如果使用了新的度量、目标函数或优化算法,则应充分定义和描述它,包括其数学公式、基本原理、输入、参数、解释、限制和在面板设计决策过程中的作用。避免在OMIP中引入新的评估指标,除非它们对面板设计至关重要,并且可以完整地描述。相反,在单独的方法出版物中引入并验证实质性的新指标或优化策略。这部分对临床小组特别重要,但也可能与研究小组相关。根据CLSI(临床和实验室标准协会)H62[19]中概述的面板预期应用确定适当的验证水平。CLSI H62表22明确了基于预期用途的验证方案,帮助研究人员为其测定制定适当的验证计划。国际血液学标准化委员会(ICSH)与国际临床细胞术学会(ICCS)合作出版的五部分实践指南系列提供了定义接受标准的详细实用指南,作为CLSI H62的补充[20-24]。明确说明所选择的验证框架、验收标准和用于评估小组性能的关键读数。演示和讨论相应的验证程序和结果。常用的验证参数包括但不限于样品稳定性、染色后稳定性、精密度或再现性、灵敏度和特异性。如果计划对小面板进行修改以适应罕见的患者表型[25],则在单独的部分提供适当的信息和数据。如果小组编辑是实质性的,编辑可能会建议他们在单独的出版物中展示。在任何一种情况下,都需要演示优化和验证[26]。用数据可用性声明结束每篇稿件,该声明提供数字对象标识符(DOI)、登录号或永久性在线存储库的其他持久标识符,并指定存放了哪些数据。使用符合细胞术第a部分作者指南的适当公共数据库,作者应包括代表性数据、单染色对照和生物对照。必须提供用于生成图1的数据文件。如果手稿声称该面板适用于其他组织、动物品系或物种或疾病状态,则还必须包括支持数据文件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cytometry Part A
Cytometry Part A 生物-生化研究方法
CiteScore
8.10
自引率
13.50%
发文量
183
审稿时长
4-8 weeks
期刊介绍: Cytometry Part A, the journal of quantitative single-cell analysis, features original research reports and reviews of innovative scientific studies employing quantitative single-cell measurement, separation, manipulation, and modeling techniques, as well as original articles on mechanisms of molecular and cellular functions obtained by cytometry techniques. The journal welcomes submissions from multiple research fields that fully embrace the study of the cytome: Biomedical Instrumentation Engineering Biophotonics Bioinformatics Cell Biology Computational Biology Data Science Immunology Parasitology Microbiology Neuroscience Cancer Stem Cells Tissue Regeneration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书