Tau20-RETROmapping System Identifies Driver-Like Activation Patterns in Real Time During Persistent Atrial Fibrillation.

IF 9.3 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Oliver S Jones, Nick Linton, Stewart Bissett, Simos Koutsoftidis, Jamie Kay, Huiyi Wu, Ji-Jian Chow, Norman Qureshi, Tina Baykaner, Junaid Zaman, Thorsten Lewalter, Ali Anil Demircali, Qindong Zheng, Fergus Heaney, Ivin Jose, Louisa C Malcolme-Lawes, Michael Koa-Wing, Boon Lim, Ahran D Arnold, Nicholas S Peters, Daniel Keene, Fu Siong Ng, Zachary I Whinnett, Burak Temelkuran, Emmanuel Drakakis, Prapa Kanagaratnam
{"title":"Tau20-RETROmapping System Identifies Driver-Like Activation Patterns in Real Time During Persistent Atrial Fibrillation.","authors":"Oliver S Jones, Nick Linton, Stewart Bissett, Simos Koutsoftidis, Jamie Kay, Huiyi Wu, Ji-Jian Chow, Norman Qureshi, Tina Baykaner, Junaid Zaman, Thorsten Lewalter, Ali Anil Demircali, Qindong Zheng, Fergus Heaney, Ivin Jose, Louisa C Malcolme-Lawes, Michael Koa-Wing, Boon Lim, Ahran D Arnold, Nicholas S Peters, Daniel Keene, Fu Siong Ng, Zachary I Whinnett, Burak Temelkuran, Emmanuel Drakakis, Prapa Kanagaratnam","doi":"10.1161/CIRCEP.126.015039","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Conventional activation mapping of atrial fibrillation (AF) during clinical procedures is limited by low-amplitude, fractionated electrograms and cycle length variability. The Tau20-RETROmapping stimulator-recorder system (TauRhythm Therapies, United Kingdom) is an investigational device used to identify nonpulmonary vein AF drivers by real-time, high-density activation mapping of uniform wavefronts during AF. We validated the accuracy of the system and applied it to left atrial mapping for evidence of AF drivers.</p><p><strong>Methods: </strong>Left atrial geometry was acquired using a 3-dimensional electroanatomic mapping system with high-density mapping catheters (CARTO 3 with Optrell, or EnSite X with HD Grid). Electrograms were recorded for 30 seconds at multiple left atrial sites. The Tau20-RETROmapping system generates activation maps of organized wavefronts. System performance was manually validated against randomly sampled local electrograms using a grid sweep of thresholds to identify Pareto-optimal parameters in sinus rhythm, atrial pacing, atrial tachycardia (AT), and AF. The system was then applied to identify putative driver activation patterns during persistent AF.</p><p><strong>Results: </strong>We studied 24 patients undergoing pulmonary vein isolation for AF. Six patients presented in sinus rhythm or AT, in whom the system demonstrated a sensitivity of 100.0% (95% CI, 80.5%-100.0%) and a specificity of 100.0% (85.2%-100.0%). Eighteen patients were mapped in AF: the system had a sensitivity of 94.4% (86.2%-98.4%) and a specificity of 97.1% (89.9%-99.6%) when identifying organized AF wavefronts, and accurately identified the earliest activation in 89.6% (79.7%-95.7%) of waves. Stable propagation originating from the left atrial appendage (LAA) was observed in 3/18 patients, while 8/18 demonstrated competing propagation toward and away from the LAA. Conduction away from the LAA was detected along the anterior (8/18 patients), lateral (8/18 patients), and posterior (7/18 patients) walls. No propagation near the LAA was observed in 6/18 patients.</p><p><strong>Conclusions: </strong>The Tau20-RETROmapping system enables real-time activation mapping of AF, with the most convincing driver-like areas being identified around the LAA.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e015039"},"PeriodicalIF":9.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.126.015039","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Conventional activation mapping of atrial fibrillation (AF) during clinical procedures is limited by low-amplitude, fractionated electrograms and cycle length variability. The Tau20-RETROmapping stimulator-recorder system (TauRhythm Therapies, United Kingdom) is an investigational device used to identify nonpulmonary vein AF drivers by real-time, high-density activation mapping of uniform wavefronts during AF. We validated the accuracy of the system and applied it to left atrial mapping for evidence of AF drivers.

Methods: Left atrial geometry was acquired using a 3-dimensional electroanatomic mapping system with high-density mapping catheters (CARTO 3 with Optrell, or EnSite X with HD Grid). Electrograms were recorded for 30 seconds at multiple left atrial sites. The Tau20-RETROmapping system generates activation maps of organized wavefronts. System performance was manually validated against randomly sampled local electrograms using a grid sweep of thresholds to identify Pareto-optimal parameters in sinus rhythm, atrial pacing, atrial tachycardia (AT), and AF. The system was then applied to identify putative driver activation patterns during persistent AF.

Results: We studied 24 patients undergoing pulmonary vein isolation for AF. Six patients presented in sinus rhythm or AT, in whom the system demonstrated a sensitivity of 100.0% (95% CI, 80.5%-100.0%) and a specificity of 100.0% (85.2%-100.0%). Eighteen patients were mapped in AF: the system had a sensitivity of 94.4% (86.2%-98.4%) and a specificity of 97.1% (89.9%-99.6%) when identifying organized AF wavefronts, and accurately identified the earliest activation in 89.6% (79.7%-95.7%) of waves. Stable propagation originating from the left atrial appendage (LAA) was observed in 3/18 patients, while 8/18 demonstrated competing propagation toward and away from the LAA. Conduction away from the LAA was detected along the anterior (8/18 patients), lateral (8/18 patients), and posterior (7/18 patients) walls. No propagation near the LAA was observed in 6/18 patients.

Conclusions: The Tau20-RETROmapping system enables real-time activation mapping of AF, with the most convincing driver-like areas being identified around the LAA.

Tau20-RETROmapping系统实时识别持续性心房颤动的驱动样激活模式。
背景:在临床过程中,传统的心房颤动(AF)的激活映射受到低振幅、分步电图和周期长度可变性的限制。Tau20-RETROmapping刺激-记录系统(英国taurhyth疗法公司)是一种研究设备,用于通过AF期间均匀波前的实时高密度激活映射来识别非肺静脉AF驱动因素。我们验证了该系统的准确性,并将其应用于左心房定位以寻找AF驱动因素的证据。方法:采用高密度测图导管(CARTO 3与Optrell,或EnSite X与HD Grid)三维电解剖测图系统获得左心房几何形状。记录左心房多个部位30秒的电图。Tau20-RETROmapping系统生成有组织波前的激活图。系统性能通过阈值网格扫描对随机采样的局部电图进行手动验证,以确定窦性心律、心房起搏、房性心动过速(AT)和房颤的帕累托最优参数。然后,该系统被应用于识别持续房颤期间假定的驾驶员激活模式。我们研究了24例因房颤而接受肺静脉隔离的患者。6例患者表现为窦性心律或AT,该系统的敏感性为100.0% (95% CI, 80.5%-100.0%),特异性为100.0%(85.2%-100.0%)。18例患者在房颤中进行了定位:该系统在识别有组织的房颤波阵面时灵敏度为94.4%(86.2% ~ 98.4%),特异性为97.1%(89.9% ~ 99.6%),准确识别出89.6%(79.7% ~ 95.7%)的最早激活波。在3/18的患者中,左心耳(LAA)的增殖稳定,而8/18的患者则表现出向LAA方向和远离LAA方向的竞争增殖。沿前壁(8/18例)、侧壁(8/18例)和后壁(7/18例)检测到远离LAA的传导。6/18例患者LAA附近未见繁殖。结论:Tau20-RETROmapping系统能够实现AF的实时激活映射,在LAA周围识别出最令人信服的驱动样区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书