Prospective clinical implementation of the robust optimization planning technique in long-course photon radiotherapy treatment for lung cancer.

IF 1.7 4区 医学 Q4 ONCOLOGY
Francesco Dionisi, Marco D'Andrea, Isabella Sperduti, Erminia Infusino, Lucia Goanta, Anna Ianiro, Antonella Soriani, Lamberto Widesott, Giuseppe Sanguineti
{"title":"Prospective clinical implementation of the robust optimization planning technique in long-course photon radiotherapy treatment for lung cancer.","authors":"Francesco Dionisi, Marco D'Andrea, Isabella Sperduti, Erminia Infusino, Lucia Goanta, Anna Ianiro, Antonella Soriani, Lamberto Widesott, Giuseppe Sanguineti","doi":"10.1016/j.meddos.2026.06.001","DOIUrl":null,"url":null,"abstract":"<p><p>Optimizing photon radiotherapy techniques is crucial in the integrated treatment of lung cancer. We prospectively evaluated the clinical implementation of the robust optimization (RO) technique in comparison with the conventional planning target volume (PTV) optimization (PTVO) technique. Unresectable stage III non-small cell lung cancer (NSCLC) or limited small cell lung cancer patients undergoing definitive radiotherapy were eligible. For each patient, 2 planning approaches were compared: (1) internal target volume (ITV)-based RO, with 0.5 cm setup uncertainties in cardinal directions around ITV and (2) PTVO, with PTV = ITV+0.5 cm isotropic expansion. Comparison included nominal and robust target coverage (TC), healthy tissue sparing, and, for NSCLC patients, estimated dose to immune cells (EDIC) and normal tissue complication probability (NTCP) values for pulmonary, esophageal toxicity, and 24-month mortality. Robustness evaluation (RE) acceptance criteria were ITV V95% ≥ 95% and spinal cord maximum dose < 45 Gy in all perturbed scenarios. Each enrolled patient was actually treated with the plan (RO or standard PTVO) that was judged superior in terms of TC and organs at risk (OAR) sparing. The Wilcoxon test was used for data analysis. p < 0.05 was considered statistically significant. Between June 2024 and June 2025, 24 patients were prospectively enrolled. Nominal TC metrics were comparable between RO and PTVO. Lungs, heart, and esophagus doses were significantly reduced with RO. RO significantly reduced EDIC (p = 0.002), pulmonary (p = 0.0015), and esophageal (p = 0.003) NTCP values. TC and cord maximum dose acceptance criteria at RE were fulfilled in 99.4%/99.4% and in 100%/91% of the perturbed scenarios for RO and PTVO, respectively. At planning comparison, the RO was selected for the actual clinical treatment and delivery in 21 (87%) patients. The first clinical implementation of RO for lung cancer radiotherapy was feasible and promising; RO represents a valid alternative to PTVO in this setting.</p>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.meddos.2026.06.001","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Optimizing photon radiotherapy techniques is crucial in the integrated treatment of lung cancer. We prospectively evaluated the clinical implementation of the robust optimization (RO) technique in comparison with the conventional planning target volume (PTV) optimization (PTVO) technique. Unresectable stage III non-small cell lung cancer (NSCLC) or limited small cell lung cancer patients undergoing definitive radiotherapy were eligible. For each patient, 2 planning approaches were compared: (1) internal target volume (ITV)-based RO, with 0.5 cm setup uncertainties in cardinal directions around ITV and (2) PTVO, with PTV = ITV+0.5 cm isotropic expansion. Comparison included nominal and robust target coverage (TC), healthy tissue sparing, and, for NSCLC patients, estimated dose to immune cells (EDIC) and normal tissue complication probability (NTCP) values for pulmonary, esophageal toxicity, and 24-month mortality. Robustness evaluation (RE) acceptance criteria were ITV V95% ≥ 95% and spinal cord maximum dose < 45 Gy in all perturbed scenarios. Each enrolled patient was actually treated with the plan (RO or standard PTVO) that was judged superior in terms of TC and organs at risk (OAR) sparing. The Wilcoxon test was used for data analysis. p < 0.05 was considered statistically significant. Between June 2024 and June 2025, 24 patients were prospectively enrolled. Nominal TC metrics were comparable between RO and PTVO. Lungs, heart, and esophagus doses were significantly reduced with RO. RO significantly reduced EDIC (p = 0.002), pulmonary (p = 0.0015), and esophageal (p = 0.003) NTCP values. TC and cord maximum dose acceptance criteria at RE were fulfilled in 99.4%/99.4% and in 100%/91% of the perturbed scenarios for RO and PTVO, respectively. At planning comparison, the RO was selected for the actual clinical treatment and delivery in 21 (87%) patients. The first clinical implementation of RO for lung cancer radiotherapy was feasible and promising; RO represents a valid alternative to PTVO in this setting.

稳健优化规划技术在肺癌光子放射治疗中长期应用的前瞻性临床应用。
优化光子放疗技术是肺癌综合治疗的关键。我们对鲁棒优化(RO)技术的临床应用进行了前瞻性评估,并与传统的计划靶体积优化(PTV)技术进行了比较。不能切除的III期非小细胞肺癌(NSCLC)或限制性小细胞肺癌患者接受最终放疗。对于每位患者,比较了两种计划方法:(1)基于内靶体积(ITV)的RO,在ITV周围的基本方向上有0.5 cm的设置不确定性;(2)PTVO, PTV = ITV+0.5 cm各向同性扩张。比较包括标称和稳健靶标覆盖(TC)、健康组织保留,对于非小细胞肺癌患者,肺毒性、食管毒性和24个月死亡率的免疫细胞估计剂量(EDIC)和正常组织并发症概率(NTCP)值。稳健性评价(RE)接受标准为ITV V95%≥95%,脊髓最大剂量< 45 Gy。每个入组的患者实际上都接受了在TC和危险器官(OAR)保留方面被认为优越的方案(RO或标准PTVO)的治疗。采用Wilcoxon检验进行数据分析。p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Dosimetry
Medical Dosimetry 医学-核医学
CiteScore
2.40
自引率
0.00%
发文量
51
审稿时长
34 days
期刊介绍: Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书