The impact of glenoid/humeral lateralization and distalization angles based in the pattern of reverse shoulder arthroplasty

IF 2 Q2 Medicine
JSES International Pub Date : 2026-07-01 Epub Date: 2026-05-04 DOI:10.1016/j.jseint.2026.101729
Giovanni Di Giacomo MD, Leonardo Moreno Rodriguez MD, Petar Golijanin MD, Andrea Vespasiani MD, Valerio Antonini MD, Capt. Matthew T. Provencher MD MBA, Nicola de Gasperis MD
{"title":"The impact of glenoid/humeral lateralization and distalization angles based in the pattern of reverse shoulder arthroplasty","authors":"Giovanni Di Giacomo MD,&nbsp;Leonardo Moreno Rodriguez MD,&nbsp;Petar Golijanin MD,&nbsp;Andrea Vespasiani MD,&nbsp;Valerio Antonini MD,&nbsp;Capt. Matthew T. Provencher MD MBA,&nbsp;Nicola de Gasperis MD","doi":"10.1016/j.jseint.2026.101729","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The biomechanics of reverse shoulder arthroplasty (RSA) rely on deltoid function. The center of rotation of the glenohumeral joint in RSA is more medial and distal when compared to the native joint, and proper soft-tissue tensioning is essential to achieve a stable joint with a good range of motion (ROM). The current RSA systems on the market allow for various placements of humeral and glenoid components (lateralized, medialized, distalized). No post-operative radiographic parameters currently consider the glenoid and humeral components' position separately. The aims of this study are to (1) measure glenoid and humeral component angles specific to different implants and (2) to investigate whether these angles correlate with clinical outcomes.</div></div><div><h3>Methods</h3><div>A retrospective analysis of 74 patients who underwent reverse shoulder prosthesis between 2018 and 2022 was performed. Different subtypes of RSA prosthesis were identified (medialized glenoid/lateralized humerus, lateralized glenoid/medialized humerus, and lateralized glenoid/lateralized humerus). Angle measurements were defined to determine the lateralization and distalization of each component in true anteroposterior radiographs (Grashey view) of the shoulder. The clinical results were collected, including a Simple Shoulder est, Single Assessment Numeric Evaluation, and Constant score.</div></div><div><h3>Results</h3><div>All angles showed excellent intra-rater and inter-rater agreement. No correlation was found between ROM and post-operative radiographic measurements, and there were no significant differences between the different RSA subtypes in clinical outcomes.</div></div><div><h3>Conclusion</h3><div>The main objectives to be met are the post-operative scores, ROM, and patient satisfaction after RSA; however, there are still no reliable measures in post-operative radiographs that correlate with clinical outcomes. The current angles obtained on post-operative radiographs allow us to assess the prosthesis's placement degree due to each of the components but not to predict ROM or clinical outcomes.</div></div>","PeriodicalId":34444,"journal":{"name":"JSES International","volume":"10 4","pages":"Article 101729"},"PeriodicalIF":2.0000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13311811/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSES International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666638326001143","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The biomechanics of reverse shoulder arthroplasty (RSA) rely on deltoid function. The center of rotation of the glenohumeral joint in RSA is more medial and distal when compared to the native joint, and proper soft-tissue tensioning is essential to achieve a stable joint with a good range of motion (ROM). The current RSA systems on the market allow for various placements of humeral and glenoid components (lateralized, medialized, distalized). No post-operative radiographic parameters currently consider the glenoid and humeral components' position separately. The aims of this study are to (1) measure glenoid and humeral component angles specific to different implants and (2) to investigate whether these angles correlate with clinical outcomes.

Methods

A retrospective analysis of 74 patients who underwent reverse shoulder prosthesis between 2018 and 2022 was performed. Different subtypes of RSA prosthesis were identified (medialized glenoid/lateralized humerus, lateralized glenoid/medialized humerus, and lateralized glenoid/lateralized humerus). Angle measurements were defined to determine the lateralization and distalization of each component in true anteroposterior radiographs (Grashey view) of the shoulder. The clinical results were collected, including a Simple Shoulder est, Single Assessment Numeric Evaluation, and Constant score.

Results

All angles showed excellent intra-rater and inter-rater agreement. No correlation was found between ROM and post-operative radiographic measurements, and there were no significant differences between the different RSA subtypes in clinical outcomes.

Conclusion

The main objectives to be met are the post-operative scores, ROM, and patient satisfaction after RSA; however, there are still no reliable measures in post-operative radiographs that correlate with clinical outcomes. The current angles obtained on post-operative radiographs allow us to assess the prosthesis's placement degree due to each of the components but not to predict ROM or clinical outcomes.
基于反向肩关节置换术模式的盂/肱骨侧移和远移角度的影响。
背景:反向肩关节置换术(RSA)的生物力学依赖于三角肌功能。与正常关节相比,RSA的盂肱关节的旋转中心更靠近内侧和远端,适当的软组织张紧对于实现具有良好活动范围(ROM)的稳定关节至关重要。目前市场上的RSA系统允许肱骨和盂骨假体的不同放置(侧化、中化、远化)。目前没有术后影像学参数单独考虑肩关节和肱骨部位的位置。本研究的目的是:(1)测量不同植入物的关节盂和肱骨成分角度;(2)研究这些角度是否与临床结果相关。方法:回顾性分析2018 - 2022年间74例接受反向肩关节假体手术的患者。确定了不同亚型的RSA假体(内侧盂/肱骨偏侧、内侧盂/肱骨偏侧和外侧盂/肱骨偏侧)。定义角度测量以确定肩部真实正位x线片(Grashey视图)中每个部件的侧位和远位。收集临床结果,包括简单肩部测试,单一评估数值评估和恒定评分。结果:各角度均表现出良好的内、间一致性。ROM与术后影像学测量无相关性,不同RSA亚型的临床结果无显著差异。结论:RSA的主要目标是术后评分、ROM和患者满意度;然而,在术后x线片中仍然没有可靠的测量方法与临床结果相关。术后x线片上获得的当前角度允许我们评估假体由于每个部件的放置程度,但不能预测ROM或临床结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JSES International
JSES International Medicine-Surgery
CiteScore
2.80
自引率
0.00%
发文量
174
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书