Frameless Intraoperative CT-Guided Deep Brain Stimulation: A Multi-Institutional Analysis of Stereotactic Accuracy and Operative Metrics.

IF 2.1 4区 医学 Q3 NEUROIMAGING
Matthan Tharakan, Kishore Balasubramanian, Rohan Aggarwal, Kiana Prather, Helen Shi, Ellen L Air, Brian Dalm, Arjun Khanna, Ryan Kochanski, Paul S Larson, Nader Pouratian, Andrew K Conner
{"title":"Frameless Intraoperative CT-Guided Deep Brain Stimulation: A Multi-Institutional Analysis of Stereotactic Accuracy and Operative Metrics.","authors":"Matthan Tharakan, Kishore Balasubramanian, Rohan Aggarwal, Kiana Prather, Helen Shi, Ellen L Air, Brian Dalm, Arjun Khanna, Ryan Kochanski, Paul S Larson, Nader Pouratian, Andrew K Conner","doi":"10.1159/000553285","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>MRI-guided stereotaxy provides high accuracy but is limited by the need for an interventional/intraoperative MRI environment and associated workflow complexity. ClearPoint Software v3.0 extends an established stereotactic workflow to a conventional operating room using intraoperative CT (iCT) imaging. We aimed to evaluate stereotactic accuracy and operative metrics of the ClearPoint frameless iCT image-guided system for deep brain stimulation (DBS) lead implantation.</p><p><strong>Methods: </strong>We performed a multicenter retrospective review of consecutive DBS lead placement procedures supported by ClearPoint Neuro Navigation System Software Version 3.0 across 7 sites during a limited market release (February 1, 2025-May 1, 2025). Primary outcomes were radial targeting error (distance between planned trajectory endpoint and final device tip position in X-Y) and operative duration (skin incision to closure).</p><p><strong>Results: </strong>Twenty-three procedures were analyzed. Median age was 67 years (range 32-89). Most cases were bilateral (87%, n = 20). Targets included subthalamic nucleus (39%, n = 9), ventral intermediate nucleus (39%, n = 9), and globus pallidus internus (22%, n = 5). Targeting accuracy was high, with median radial error of 0.20 mm on the left (range 0-1.60) and 0.20 mm on the right (range 0-1.0). Median operative duration was 127 min (range 69-225). Median intraoperative scans were 6, and procedures required a median of 2 adjustments per side.</p><p><strong>Conclusion: </strong>In this first multi-institution report of ClearPoint Software v3.0 for DBS lead placement, the frameless iCT workflow demonstrated consistent submillimeter accuracy with favorable operative metrics in a standard operating room setting.</p>","PeriodicalId":22078,"journal":{"name":"Stereotactic and Functional Neurosurgery","volume":" ","pages":"1-12"},"PeriodicalIF":2.1000,"publicationDate":"2026-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stereotactic and Functional Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000553285","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: MRI-guided stereotaxy provides high accuracy but is limited by the need for an interventional/intraoperative MRI environment and associated workflow complexity. ClearPoint Software v3.0 extends an established stereotactic workflow to a conventional operating room using intraoperative CT (iCT) imaging. We aimed to evaluate stereotactic accuracy and operative metrics of the ClearPoint frameless iCT image-guided system for deep brain stimulation (DBS) lead implantation.

Methods: We performed a multicenter retrospective review of consecutive DBS lead placement procedures supported by ClearPoint Neuro Navigation System Software Version 3.0 across 7 sites during a limited market release (February 1, 2025-May 1, 2025). Primary outcomes were radial targeting error (distance between planned trajectory endpoint and final device tip position in X-Y) and operative duration (skin incision to closure).

Results: Twenty-three procedures were analyzed. Median age was 67 years (range 32-89). Most cases were bilateral (87%, n = 20). Targets included subthalamic nucleus (39%, n = 9), ventral intermediate nucleus (39%, n = 9), and globus pallidus internus (22%, n = 5). Targeting accuracy was high, with median radial error of 0.20 mm on the left (range 0-1.60) and 0.20 mm on the right (range 0-1.0). Median operative duration was 127 min (range 69-225). Median intraoperative scans were 6, and procedures required a median of 2 adjustments per side.

Conclusion: In this first multi-institution report of ClearPoint Software v3.0 for DBS lead placement, the frameless iCT workflow demonstrated consistent submillimeter accuracy with favorable operative metrics in a standard operating room setting.

利用ClearPoint无帧术中ct图像指导的立体定向精度和手术指标:一项多机构分析。
MRI引导的立体定位提供了很高的准确性,但受到介入/术中MRI环境和相关工作流程复杂性的限制。ClearPoint软件v3.0使用术中CT (iCT)成像技术将已建立的立体定向工作流程扩展到传统手术室。目的:评价ClearPoint无框架iCT图像引导系统用于脑深部刺激(DBS)导联植入的立体定向精度和操作指标。方法:在有限的市场发布期间(2025年2月1日至2025年5月1日),我们在7个地点对ClearPoint神经导航系统软件版本3.0支持的连续DBS引线放置程序进行了多中心回顾性审查。主要结果是径向靶向误差(计划轨迹终点与最终装置尖端位置在X-Y上的距离)和手术时间(皮肤切口到闭合)。结果:分析了23例手术。中位年龄为67岁(范围39-89)。大多数病例为双侧(87%,n=20)。目标包括丘脑下核(39%,n=9)、腹侧中间核(39%,n=9)和内苍白球(22%,n=5)。瞄准精度高,左径向误差中值为0.20 mm(范围0-1.60),右径向误差中值为0.20 mm(范围0-1.0)。中位手术时间203分钟(范围125-330)。术中平均扫描次数为6次,每侧平均需要调整2次。结论:在ClearPoint软件v3.0用于DBS引线放置的第一份多机构报告中,无框iCT工作流程在标准手术室设置中表现出一致的亚毫米精度和良好的操作指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
0.00%
发文量
33
审稿时长
3 months
期刊介绍: ''Stereotactic and Functional Neurosurgery'' provides a single source for the reader to keep abreast of developments in the most rapidly advancing subspecialty within neurosurgery. Technological advances in computer-assisted surgery, robotics, imaging and neurophysiology are being applied to clinical problems with ever-increasing rapidity in stereotaxis more than any other field, providing opportunities for new approaches to surgical and radiotherapeutic management of diseases of the brain, spinal cord, and spine. Issues feature advances in the use of deep-brain stimulation, imaging-guided techniques in stereotactic biopsy and craniotomy, stereotactic radiosurgery, and stereotactically implanted and guided radiotherapeutics and biologicals in the treatment of functional and movement disorders, brain tumors, and other diseases of the brain. Background information from basic science laboratories related to such clinical advances provides the reader with an overall perspective of this field. Proceedings and abstracts from many of the key international meetings furnish an overview of this specialty available nowhere else. ''Stereotactic and Functional Neurosurgery'' meets the information needs of both investigators and clinicians in this rapidly advancing field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书