{"title":"Optimizing laboratory quality with sigma metrics: Application of CLIA 2024 total allowable error guidelines.","authors":"Anurag Sankhyan, Onjal Kamlakar Taywade, Sumita Sharma","doi":"10.1177/00045632261466864","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundStatistical quality control continues to serve as the cornerstone for ensuring the accuracy and reliability of laboratory investigations. The current research aimed to evaluate the performance of biochemistry parameters using Six Sigma metrics in light of revised CLIA (Clinical Laboratory Improvement Amendments) total allowable error (TEa) 2024 guidelines, to guide the application of appropriate quality control strategies.MethodsQuality control data for 20 chemistry parameters analyzed on the Fully Automated Biochemistry analyzer were evaluated using Six Sigma methodology. Internal quality control (IQC) and external quality assessment scheme (EQAS) data from December 2023 to May 2024 were collected. Coefficient of variation (%), bias (%) and TEa based on CLIA and Ricos biological variation guidelines were used to calculate sigma metrics. All quality control data were entered and analyzed using Microsoft Excel (Microsoft Corporation, Redmond, WA, USA).ResultsThe laboratory showed excellent (≥6 sigma) performance for direct bilirubin and HDL-cholesterol. Albumin, alkaline phosphatase, aspartate transaminase, cholesterol, glucose, iron, potassium, total iron-binding capacity and triglycerides achieved minimum sigma performance standard (>3) at one level. However, the other chemistry parameters did not meet the minimum sigma performance standard across all assay range.ConclusionThe laboratories need to reassess the performance of various biochemical parameters to redefine quality control protocols as the CLIA 2024 guidelines have tightened the total allowable error goals.</p>","PeriodicalId":8005,"journal":{"name":"Annals of Clinical Biochemistry","volume":" ","pages":"45632261466864"},"PeriodicalIF":1.1000,"publicationDate":"2026-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00045632261466864","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
BackgroundStatistical quality control continues to serve as the cornerstone for ensuring the accuracy and reliability of laboratory investigations. The current research aimed to evaluate the performance of biochemistry parameters using Six Sigma metrics in light of revised CLIA (Clinical Laboratory Improvement Amendments) total allowable error (TEa) 2024 guidelines, to guide the application of appropriate quality control strategies.MethodsQuality control data for 20 chemistry parameters analyzed on the Fully Automated Biochemistry analyzer were evaluated using Six Sigma methodology. Internal quality control (IQC) and external quality assessment scheme (EQAS) data from December 2023 to May 2024 were collected. Coefficient of variation (%), bias (%) and TEa based on CLIA and Ricos biological variation guidelines were used to calculate sigma metrics. All quality control data were entered and analyzed using Microsoft Excel (Microsoft Corporation, Redmond, WA, USA).ResultsThe laboratory showed excellent (≥6 sigma) performance for direct bilirubin and HDL-cholesterol. Albumin, alkaline phosphatase, aspartate transaminase, cholesterol, glucose, iron, potassium, total iron-binding capacity and triglycerides achieved minimum sigma performance standard (>3) at one level. However, the other chemistry parameters did not meet the minimum sigma performance standard across all assay range.ConclusionThe laboratories need to reassess the performance of various biochemical parameters to redefine quality control protocols as the CLIA 2024 guidelines have tightened the total allowable error goals.
期刊介绍:
Annals of Clinical Biochemistry is the fully peer reviewed international journal of the Association for Clinical Biochemistry and Laboratory Medicine.
Annals of Clinical Biochemistry accepts papers that contribute to knowledge in all fields of laboratory medicine, especially those pertaining to the understanding, diagnosis and treatment of human disease. It publishes papers on clinical biochemistry, clinical audit, metabolic medicine, immunology, genetics, biotechnology, haematology, microbiology, computing and management where they have both biochemical and clinical relevance. Papers describing evaluation or implementation of commercial reagent kits or the performance of new analysers require substantial original information. Unless of exceptional interest and novelty, studies dealing with the redox status in various diseases are not generally considered within the journal''s scope. Studies documenting the association of single nucleotide polymorphisms (SNPs) with particular phenotypes will not normally be considered, given the greater strength of genome wide association studies (GWAS). Research undertaken in non-human animals will not be considered for publication in the Annals.
Annals of Clinical Biochemistry is also the official journal of NVKC (de Nederlandse Vereniging voor Klinische Chemie) and JSCC (Japan Society of Clinical Chemistry).