{"title":"Impact of application repetition on Joule heating and lesion formation using a circular-shaped pulsed field catheter.","authors":"Mizuki Okumura, Shintaro Yamagami, Masaya Akiyama, Yuta Nakano, Yu Amano, Toyoki Okuda, Tsukasa Motoyoshi, Ryuki Chatani, Hirokazu Kondo, Toshihiro Tamura","doi":"10.1007/s10840-026-02379-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Pulsed field ablation (PFA) is a non-thermal ablation modality, but repeated high-voltage applications can still cause Joule heating at the electrode-tissue interface. We evaluated the effects of application repetition and inter-application intervals on temperature rise and lesion depth using a circular-shaped PFA catheter.</p><p><strong>Methods and results: </strong>In an in vitro potato model, a circular-shaped PFA catheter was tested under five settings: 1×, 2×, 2× with a 10-s interval, 4×, and 4× with a 10-s interval. Maximum electrode surface temperature was measured using a thermal camera, and lesion depth was assessed by TTC staining (n = 5 per setting). Temperature increased significantly with application repetition and was attenuated by a 10-s interval (overall P < 0.0001). Lesion depth also increased with repetition (overall P < 0.0001), but did not differ significantly between interval and no-interval conditions at equal application numbers.</p><p><strong>Conclusion: </strong>In this simplified in vitro model, a short inter-application interval was associated with attenuation of temperature rise during repeated PFA delivery, while lesion depth was not significantly reduced.</p>","PeriodicalId":520675,"journal":{"name":"Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing","volume":" ","pages":"1563-1566"},"PeriodicalIF":2.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10840-026-02379-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Pulsed field ablation (PFA) is a non-thermal ablation modality, but repeated high-voltage applications can still cause Joule heating at the electrode-tissue interface. We evaluated the effects of application repetition and inter-application intervals on temperature rise and lesion depth using a circular-shaped PFA catheter.
Methods and results: In an in vitro potato model, a circular-shaped PFA catheter was tested under five settings: 1×, 2×, 2× with a 10-s interval, 4×, and 4× with a 10-s interval. Maximum electrode surface temperature was measured using a thermal camera, and lesion depth was assessed by TTC staining (n = 5 per setting). Temperature increased significantly with application repetition and was attenuated by a 10-s interval (overall P < 0.0001). Lesion depth also increased with repetition (overall P < 0.0001), but did not differ significantly between interval and no-interval conditions at equal application numbers.
Conclusion: In this simplified in vitro model, a short inter-application interval was associated with attenuation of temperature rise during repeated PFA delivery, while lesion depth was not significantly reduced.