A Novel Adjustable Tandem and Ring Applicator for Improved Dosimetry in Cervical Cancer HDR Brachytherapy.

IF 2.7 4区 医学 Q3 ONCOLOGY
Technology in Cancer Research & Treatment Pub Date : 2026-01-01 Epub Date: 2026-06-22 DOI:10.1177/15330338261463597
Ivan M Buzurovic, Robert A Cormack
{"title":"A Novel Adjustable Tandem and Ring Applicator for Improved Dosimetry in Cervical Cancer HDR Brachytherapy.","authors":"Ivan M Buzurovic, Robert A Cormack","doi":"10.1177/15330338261463597","DOIUrl":null,"url":null,"abstract":"<p><p>IntroductionCervical cancer brachytherapy requires highly conformal dose delivery while minimizing radiation exposure to surrounding organs at risk. However, conventional tandem and ring applicators are limited by fixed geometry that may not optimally accommodate patient-specific anatomy. The purpose of this work was to evaluate the dosimetric performance of a novel tandem and ring applicator (RTA) featuring adjustable tandem translation relative to the ring, intended to improve organ-at-risk (OAR) sparing while preserving target coverage in high-dose-rate (HDR) brachytherapy for cervical cancer.Methods and MaterialsA novel RTA allowing linear tandem translation within the ring plane was developed to enable patient-specific alignment without altering ring position. Two cervical cancer patients treated with external beam radiotherapy (45Gy/25 fractions) followed by HDR brachytherapy (27.5Gy/5 fractions) were analyzed. Conventional and novel RTAs were sequentially applied to acquire CT-based datasets. Plans were optimized for adequate HR-CTV D90 coverage while minimizing D2cm<sup>3</sup> doses to bladder, rectum, sigmoid, and bowel. EQD2 values (α/β = 3 for OARs; 10 for HR-CTV) were compared. Five retrospective cases were replanned using the novel RTA. Point A was redefined as 2cm superior along the tandem from the cervical os and 2cm lateral perpendicular to the tandem axis.ResultsFor patient 1, the novel RTA reduced average daily D2cm<sup>3</sup> by 0.54Gy (rectum), 0.78Gy (bladder), and 0.18Gy (sigmoid), with cumulative EQD2 reductions of 2.23Gy, 4.88Gy, and 1.05Gy, respectively. Patient 2 showed daily reductions of 0.52Gy (rectum) and 0.44Gy (bladder), with EQD2 decreases of 3.20Gy and 4.55Gy. HR-CTV EQD2 increased by 1.67Gy. Retrospective plans demonstrated consistent reductions in OAR doses.ConclusionThe novel RTA demonstrated favorable dosimetric trends for OAR sparing while maintaining target coverage in cervical HDR brachytherapy. The revised Point A definition provides a preliminary framework for anatomically consistent dose reporting in flexible tandem configurations.</p>","PeriodicalId":22203,"journal":{"name":"Technology in Cancer Research & Treatment","volume":"25 ","pages":"15330338261463597"},"PeriodicalIF":2.7000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13305905/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology in Cancer Research & Treatment","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15330338261463597","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

IntroductionCervical cancer brachytherapy requires highly conformal dose delivery while minimizing radiation exposure to surrounding organs at risk. However, conventional tandem and ring applicators are limited by fixed geometry that may not optimally accommodate patient-specific anatomy. The purpose of this work was to evaluate the dosimetric performance of a novel tandem and ring applicator (RTA) featuring adjustable tandem translation relative to the ring, intended to improve organ-at-risk (OAR) sparing while preserving target coverage in high-dose-rate (HDR) brachytherapy for cervical cancer.Methods and MaterialsA novel RTA allowing linear tandem translation within the ring plane was developed to enable patient-specific alignment without altering ring position. Two cervical cancer patients treated with external beam radiotherapy (45Gy/25 fractions) followed by HDR brachytherapy (27.5Gy/5 fractions) were analyzed. Conventional and novel RTAs were sequentially applied to acquire CT-based datasets. Plans were optimized for adequate HR-CTV D90 coverage while minimizing D2cm3 doses to bladder, rectum, sigmoid, and bowel. EQD2 values (α/β = 3 for OARs; 10 for HR-CTV) were compared. Five retrospective cases were replanned using the novel RTA. Point A was redefined as 2cm superior along the tandem from the cervical os and 2cm lateral perpendicular to the tandem axis.ResultsFor patient 1, the novel RTA reduced average daily D2cm3 by 0.54Gy (rectum), 0.78Gy (bladder), and 0.18Gy (sigmoid), with cumulative EQD2 reductions of 2.23Gy, 4.88Gy, and 1.05Gy, respectively. Patient 2 showed daily reductions of 0.52Gy (rectum) and 0.44Gy (bladder), with EQD2 decreases of 3.20Gy and 4.55Gy. HR-CTV EQD2 increased by 1.67Gy. Retrospective plans demonstrated consistent reductions in OAR doses.ConclusionThe novel RTA demonstrated favorable dosimetric trends for OAR sparing while maintaining target coverage in cervical HDR brachytherapy. The revised Point A definition provides a preliminary framework for anatomically consistent dose reporting in flexible tandem configurations.

一种用于宫颈癌HDR近距离放射治疗的新型可调串联和环形涂抹器。
宫颈癌近距离放射治疗需要高度适形的剂量,同时尽量减少对周围器官的辐射暴露。然而,传统的串联和环形涂抹器受到固定几何形状的限制,可能无法最佳地适应患者特定的解剖结构。本研究的目的是评估一种新型串联和环形涂药器(RTA)的剂量学性能,该涂药器具有相对于环可调节的串联平移,旨在提高宫颈癌高剂量率(HDR)近距离治疗中器官的风险(OAR)保护,同时保持靶标覆盖。方法和材料一种新的RTA允许在环平面内线性串联平移,使患者特异性对齐而不改变环的位置。对2例宫颈癌患者行外束放疗(45Gy/25分)后HDR近距离放疗(27.5Gy/5分)进行分析。依次应用传统rta和新型rta获取基于ct的数据集。优化方案以获得充分的HR-CTV D90覆盖率,同时尽量减少膀胱、直肠、乙状结肠和肠道的D2cm3剂量。比较EQD2值(OARs组α/β = 3, HR-CTV组10)。5例回顾性病例采用新的RTA重新规划。A点被重新定义为从颈os沿串串向上2cm和垂直于串串轴的外侧2cm。结果对于患者1,新型RTA使平均每日D2cm3降低0.54Gy(直肠)、0.78Gy(膀胱)和0.18Gy(乙状结肠),累计EQD2降低分别为2.23Gy、4.88Gy和1.05Gy。患者2每日减少0.52Gy(直肠)和0.44Gy(膀胱),EQD2分别减少3.20Gy和4.55Gy。HR-CTV EQD2升高1.67Gy。回顾性计划显示桨叶剂量持续减少。结论在宫颈HDR近距离治疗中,新型RTA显示出良好的剂量学趋势,可以在保持靶覆盖的同时保留OAR。修订后的A点定义为灵活串联配置中解剖学上一致的剂量报告提供了初步框架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.40
自引率
0.00%
发文量
202
审稿时长
2 months
期刊介绍: Technology in Cancer Research & Treatment (TCRT) is a JCR-ranked, broad-spectrum, open access, peer-reviewed publication whose aim is to provide researchers and clinicians with a platform to share and discuss developments in the prevention, diagnosis, treatment, and monitoring of cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书