Limited Impact of Column Chemistry and Length on Proteome Coverage Under High-Speed DIA.

IF 6.3 2区 生物学 Q1 BIOCHEMICAL RESEARCH METHODS
Molecular & Cellular Proteomics Pub Date : 2026-07-01 Epub Date: 2026-06-23 DOI:10.1016/j.mcpro.2026.101609
Alicia-Sophie Schebesta, Kathrin Korff, Ericka C M Itang, Vincent Albrecht, Philipp E Geyer, Johannes B Mueller-Reif
{"title":"Limited Impact of Column Chemistry and Length on Proteome Coverage Under High-Speed DIA.","authors":"Alicia-Sophie Schebesta, Kathrin Korff, Ericka C M Itang, Vincent Albrecht, Philipp E Geyer, Johannes B Mueller-Reif","doi":"10.1016/j.mcpro.2026.101609","DOIUrl":null,"url":null,"abstract":"<p><p>The evolution of mass spectrometry (MS)-based proteomics has been driven by continuous technological advances in sample preparation, liquid-phase separations, instrumentation, and data acquisition. Chromatographic performance has been recognized as a contributing factor to identification depth, particularly on earlier-generation MS platforms. Recent advances in MS sampling speed and sensitivity now raise the question of how strongly chromatographic quality continues to determine overall proteome coverage. We investigate how column chemistry and length influence proteome coverage and chromatographic selectivity under modern data-independent acquisition conditions, and whether traditional optimization priorities still apply. Spanning a matrix of experiments with five distinct stationary phases, including C18 chemistries, C8, and Phenyl-Hexyl, across eight column lengths (40-140 mm), we evaluate protein identification performance using data-independent acquisition on the Orbitrap Astral mass spectrometer. Despite differences in stationary-phase chemistry and column length, we observed remarkably convergent proteome coverage metrics. All C18 and C8 phases consistently achieved over 150,000 precursor- and approximately 9000 protein group identifications, regardless of column length variations. While retention fingerprints persisted across chemistries, these chromatographic differences did not translate into meaningful variations in proteome coverage under high-speed acquisition conditions at 200 Hz. Within the range of modern sub-2 μm reversed-phase materials tested, identification depth showed limited dependence on column chemistry and length, suggesting that for state-of-the-art stationary phases, method development priorities may increasingly favor operational robustness, throughput, and reproducibility over traditional separation optimization.</p>","PeriodicalId":18712,"journal":{"name":"Molecular & Cellular Proteomics","volume":" ","pages":"101609"},"PeriodicalIF":6.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13400878/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Molecular & Cellular Proteomics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.mcpro.2026.101609","RegionNum":2,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/23 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The evolution of mass spectrometry (MS)-based proteomics has been driven by continuous technological advances in sample preparation, liquid-phase separations, instrumentation, and data acquisition. Chromatographic performance has been recognized as a contributing factor to identification depth, particularly on earlier-generation MS platforms. Recent advances in MS sampling speed and sensitivity now raise the question of how strongly chromatographic quality continues to determine overall proteome coverage. We investigate how column chemistry and length influence proteome coverage and chromatographic selectivity under modern data-independent acquisition conditions, and whether traditional optimization priorities still apply. Spanning a matrix of experiments with five distinct stationary phases, including C18 chemistries, C8, and Phenyl-Hexyl, across eight column lengths (40-140 mm), we evaluate protein identification performance using data-independent acquisition on the Orbitrap Astral mass spectrometer. Despite differences in stationary-phase chemistry and column length, we observed remarkably convergent proteome coverage metrics. All C18 and C8 phases consistently achieved over 150,000 precursor- and approximately 9000 protein group identifications, regardless of column length variations. While retention fingerprints persisted across chemistries, these chromatographic differences did not translate into meaningful variations in proteome coverage under high-speed acquisition conditions at 200 Hz. Within the range of modern sub-2 μm reversed-phase materials tested, identification depth showed limited dependence on column chemistry and length, suggesting that for state-of-the-art stationary phases, method development priorities may increasingly favor operational robustness, throughput, and reproducibility over traditional separation optimization.

柱化学和长度对高速DIA下蛋白质组覆盖的影响有限。
基于质谱(MS)的蛋白质组学的发展是由样品制备、液相分离、仪器和数据采集等技术的不断进步所驱动的。色谱性能已被认为是鉴定深度的一个贡献因素,特别是在早期的MS平台上。质谱采样速度和灵敏度的最新进展现在提出了一个问题,即色谱质量在多大程度上继续决定整体蛋白质组覆盖范围。我们研究了在现代DIA条件下,柱化学和柱长度如何影响蛋白质组覆盖率和色谱选择性,以及传统的优化优先级是否仍然适用。跨越5种不同的固定相,包括C18化学,C8和苯基己基,跨越8个色谱柱长度(40-140 mm)的实验矩阵,我们使用Orbitrap Astral质谱仪上的数据独立采集(DIA)来评估蛋白质鉴定性能。尽管在固定相化学和柱长度的差异,我们观察到显著收敛的蛋白质组覆盖指标。无论色谱柱长度如何变化,所有C18和C8相一致地获得了超过150,000个前体和大约9,000个蛋白质组的鉴定。尽管保留指纹在不同化学物质中持续存在,但在200 Hz的高速采集条件下,这些色谱差异并没有转化为蛋白质组覆盖率的有意义的变化。在测试的现代sub-2 μm反相材料范围内,鉴定深度对色谱柱化学和长度的依赖有限,这表明对于最先进的固定相,方法开发的优先级可能越来越倾向于操作稳稳性、通量和可重复性,而不是传统的分离优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Molecular & Cellular Proteomics
Molecular & Cellular Proteomics 生物-生化研究方法
CiteScore
11.50
自引率
4.30%
发文量
131
审稿时长
84 days
期刊介绍: The mission of MCP is to foster the development and applications of proteomics in both basic and translational research. MCP will publish manuscripts that report significant new biological or clinical discoveries underpinned by proteomic observations across all kingdoms of life. Manuscripts must define the biological roles played by the proteins investigated or their mechanisms of action. The journal also emphasizes articles that describe innovative new computational methods and technological advancements that will enable future discoveries. Manuscripts describing such approaches do not have to include a solution to a biological problem, but must demonstrate that the technology works as described, is reproducible and is appropriate to uncover yet unknown protein/proteome function or properties using relevant model systems or publicly available data. Scope: -Fundamental studies in biology, including integrative "omics" studies, that provide mechanistic insights -Novel experimental and computational technologies -Proteogenomic data integration and analysis that enable greater understanding of physiology and disease processes -Pathway and network analyses of signaling that focus on the roles of post-translational modifications -Studies of proteome dynamics and quality controls, and their roles in disease -Studies of evolutionary processes effecting proteome dynamics, quality and regulation -Chemical proteomics, including mechanisms of drug action -Proteomics of the immune system and antigen presentation/recognition -Microbiome proteomics, host-microbe and host-pathogen interactions, and their roles in health and disease -Clinical and translational studies of human diseases -Metabolomics to understand functional connections between genes, proteins and phenotypes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书