Bracket transfer accuracy of two three-dimensionally printed lingual indirect bonding trays with different bracket frame designs.

IF 3.2
Natasa Suvajac, Linus Hötzel, Lea Hoffmann, Andreas Keßler, Andrea Wichelhaus, Hisham Sabbagh
{"title":"Bracket transfer accuracy of two three-dimensionally printed lingual indirect bonding trays with different bracket frame designs.","authors":"Natasa Suvajac, Linus Hötzel, Lea Hoffmann, Andreas Keßler, Andrea Wichelhaus, Hisham Sabbagh","doi":"10.2319/101625-864.1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To compare bracket transfer accuracy of two three-dimensionally (3D) printed indirect bonding tray designs for lingual indirect bonding.</p><p><strong>Materials and methods: </strong>Virtual bracket placement was performed using OnyxCeph (OnyxCeph 3D Lab, Chemnitz, Germany). Tray design 1 was designed with a low bracket frame, while tray design 2 was designed with a high bracket frame. A total of 30 bonding trays and corresponding dental models were additively manufactured, 15 per design. After indirect bonding, achieved bracket positions were scanned. Linear and angular transfer errors were assessed. Statistical analysis of mean transfer errors and frequency of clinically acceptable errors (defined as < 0.5 mm and < 2°) were performed using Mann-Whitney U-test and χ2 test.</p><p><strong>Results: </strong>Both tray designs demonstrated comparable transfer accuracy. Linear, tip, and rotation errors were mostly within clinical limits. All linear values were acceptable, except for vertical dimension in the incisors (98.3%). Rotation accuracy was high across all tooth groups (78.9-100%). Torque showed the greatest deviations, with only 11.9% of incisor brackets in the high-frame and 75.4% in the low-frame groups within acceptable limits. Overall, torque consistently had the lowest rate of clinically acceptable outcomes across both tray designs.</p><p><strong>Conclusions: </strong>Considering favorable transfer accuracy and improved handling characteristics of the low-frame tray design, its clinical application may be preferred. However, achieving high accuracy in the torque dimension remains a challenge with 3D-printed indirect bonding trays.</p>","PeriodicalId":94224,"journal":{"name":"The Angle orthodontist","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2026-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Angle orthodontist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2319/101625-864.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To compare bracket transfer accuracy of two three-dimensionally (3D) printed indirect bonding tray designs for lingual indirect bonding.

Materials and methods: Virtual bracket placement was performed using OnyxCeph (OnyxCeph 3D Lab, Chemnitz, Germany). Tray design 1 was designed with a low bracket frame, while tray design 2 was designed with a high bracket frame. A total of 30 bonding trays and corresponding dental models were additively manufactured, 15 per design. After indirect bonding, achieved bracket positions were scanned. Linear and angular transfer errors were assessed. Statistical analysis of mean transfer errors and frequency of clinically acceptable errors (defined as < 0.5 mm and < 2°) were performed using Mann-Whitney U-test and χ2 test.

Results: Both tray designs demonstrated comparable transfer accuracy. Linear, tip, and rotation errors were mostly within clinical limits. All linear values were acceptable, except for vertical dimension in the incisors (98.3%). Rotation accuracy was high across all tooth groups (78.9-100%). Torque showed the greatest deviations, with only 11.9% of incisor brackets in the high-frame and 75.4% in the low-frame groups within acceptable limits. Overall, torque consistently had the lowest rate of clinically acceptable outcomes across both tray designs.

Conclusions: Considering favorable transfer accuracy and improved handling characteristics of the low-frame tray design, its clinical application may be preferred. However, achieving high accuracy in the torque dimension remains a challenge with 3D-printed indirect bonding trays.

两种不同支架框架设计的三维印刷舌形间接粘接托盘的支架传递精度。
目的:比较两种三维打印间接粘接托盘设计用于舌侧间接粘接的托槽转移精度。材料和方法:使用OnyxCeph (OnyxCeph 3D Lab, Chemnitz, Germany)进行虚拟支架放置。托盘设计1采用低支架框架设计,托盘设计2采用高支架框架设计。共增材制造了30个粘接托盘和相应的牙模型,每个设计15个。间接粘接后,扫描获得的支架位置。评估了线性和角传递误差。采用Mann-Whitney u检验和χ2检验对平均传递误差和临床可接受误差(定义为< 0.5 mm和< 2°)频次进行统计分析。结果:两种托盘设计表现出相当的传递精度。线性、尖端和旋转误差大多在临床限制范围内。除门牙垂直尺寸(98.3%)外,所有线性值均可接受。所有牙组的旋转精度均较高(78.9-100%)。扭矩偏差最大,只有11.9%的高框组和75.4%的低框组在可接受范围内。总的来说,在两种托盘设计中,扭矩始终具有最低的临床可接受结果率。结论:考虑到低架托盘设计良好的转移精度和改善的搬运特性,其临床应用可能是可取的。然而,在扭矩尺寸上实现高精度仍然是3d打印间接粘接托盘的一个挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书