Dosimetric evaluation of beam block techniques in helical tomotherapy for extranodal nasal-type NK/T-cell lymphoma.

IF 1.7 4区 医学 Q4 ONCOLOGY
Lin Zhu, Bailin Zhang, Qiang He, Geng Yang, Huaizhi Jin, Fei Li, Haoyu Meng, Wanwei Jian, Xuetao Wang
{"title":"Dosimetric evaluation of beam block techniques in helical tomotherapy for extranodal nasal-type NK/T-cell lymphoma.","authors":"Lin Zhu, Bailin Zhang, Qiang He, Geng Yang, Huaizhi Jin, Fei Li, Haoyu Meng, Wanwei Jian, Xuetao Wang","doi":"10.1016/j.meddos.2026.04.008","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of the study was to evaluate the dosimetric effects of different virtual beam block combinations on target coverage, organ at risk (OAR) sparing, and delivery efficiency in helical tomotherapy (HT) for extranodal nasal-type NK/T-cell lymphoma (ENKTCL-NT). In addition, normal tissue complication probability (NTCP) modeling was used to assess the biological impact on OARs and to inform optimal treatment planning strategies. Twenty-six patients with stage I-II ENKTCL-NT were retrospectively analyzed. Three virtual beam block configurations for the lens and eyeball-B-OFF, B-LEN, and B-L&E-were generated. Dosimetric parameters of the target volume, physical and biological indices of OARs, monitor units (MUs), and beam-on time (BOT) were compared among the plans. Dose delivery accuracy was verified using the ArcCHECK phantom. All 3 plans achieved clinically acceptable target coverage without significant differences in target dosimetric parameters. Compared with B-OFF, B-LEN significantly reduced the maximum dose (D<sub>max</sub>), mean dose (D<sub>mean</sub>), equivalent uniform dose (EUD), and NTCP of the bilateral lenses (all p < 0.05) but did not significantly affect the eyeball dose (p > 0.05). B-L&E provided further protection: relative to B-LEN, it reduced the D<sub>max</sub> of the left and right lenses by 3.4% and 5.9%, D<sub>mean</sub> by 5.0% and 4.9%, and median NTCP by 10.3% and 21.4%, respectively (all p < 0.05). It also significantly lowered the D<sub>max</sub> and D<sub>mean</sub> of the eyeballs (p < 0.05). No significant differences were observed among the 3 plans for the brainstem, spinal cord, optic chiasm, or optic nerves (p > 0.05). Compared with B-OFF, B-L&E increased the MUs by 17.9% and BOT by 58 s (19.0%). Gamma passing rates (3%/2 mm) exceeded 90% for all the plans, meeting the American Association of Physicists in Medicine Task Group No. 218 (AAPM TG-218) clinical criteria. The virtual beam block technique in HT effectively reduces radiation exposure to the lens and eyeball while maintaining target coverage in ENKTCL-NT. The B-L&E configuration offers the greatest OAR protection, and B-LEN may be preferable when shorter treatment times are required.</p>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.meddos.2026.04.008","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the study was to evaluate the dosimetric effects of different virtual beam block combinations on target coverage, organ at risk (OAR) sparing, and delivery efficiency in helical tomotherapy (HT) for extranodal nasal-type NK/T-cell lymphoma (ENKTCL-NT). In addition, normal tissue complication probability (NTCP) modeling was used to assess the biological impact on OARs and to inform optimal treatment planning strategies. Twenty-six patients with stage I-II ENKTCL-NT were retrospectively analyzed. Three virtual beam block configurations for the lens and eyeball-B-OFF, B-LEN, and B-L&E-were generated. Dosimetric parameters of the target volume, physical and biological indices of OARs, monitor units (MUs), and beam-on time (BOT) were compared among the plans. Dose delivery accuracy was verified using the ArcCHECK phantom. All 3 plans achieved clinically acceptable target coverage without significant differences in target dosimetric parameters. Compared with B-OFF, B-LEN significantly reduced the maximum dose (Dmax), mean dose (Dmean), equivalent uniform dose (EUD), and NTCP of the bilateral lenses (all p < 0.05) but did not significantly affect the eyeball dose (p > 0.05). B-L&E provided further protection: relative to B-LEN, it reduced the Dmax of the left and right lenses by 3.4% and 5.9%, Dmean by 5.0% and 4.9%, and median NTCP by 10.3% and 21.4%, respectively (all p < 0.05). It also significantly lowered the Dmax and Dmean of the eyeballs (p < 0.05). No significant differences were observed among the 3 plans for the brainstem, spinal cord, optic chiasm, or optic nerves (p > 0.05). Compared with B-OFF, B-L&E increased the MUs by 17.9% and BOT by 58 s (19.0%). Gamma passing rates (3%/2 mm) exceeded 90% for all the plans, meeting the American Association of Physicists in Medicine Task Group No. 218 (AAPM TG-218) clinical criteria. The virtual beam block technique in HT effectively reduces radiation exposure to the lens and eyeball while maintaining target coverage in ENKTCL-NT. The B-L&E configuration offers the greatest OAR protection, and B-LEN may be preferable when shorter treatment times are required.

束块技术在结外鼻型NK/ t细胞淋巴瘤螺旋断层治疗中的剂量学评价。
该研究的目的是评估不同虚拟束块组合对结外鼻型NK/ t细胞淋巴瘤(ENKTCL-NT)螺旋ct治疗(HT)中靶标覆盖、危险器官(OAR)保留和递送效率的剂量学影响。此外,正常组织并发症概率(NTCP)模型用于评估对OARs的生物学影响,并为最佳治疗计划策略提供信息。回顾性分析26例I-II期ENKTCL-NT患者。为透镜和眼球生成了三种虚拟光束块配置:b - off、B-LEN和b - l&e。比较各方案靶体积、OARs物理和生物指标、监测单元(MUs)和照射时间(BOT)的剂量学参数。使用ArcCHECK模型验证给药准确性。所有3个计划均达到临床可接受的目标覆盖率,目标剂量学参数无显著差异。与B-OFF相比,B-LEN显著降低了双侧晶状体的最大剂量(Dmax)、平均剂量(Dmean)、等效均匀剂量(EUD)和NTCP (p均  0.05)。B-L&E提供了进一步的保护:相对于B-LEN,它使左右晶状体Dmax分别降低3.4%和5.9%,Dmean分别降低5.0%和4.9%,NTCP中位数分别降低10.3%和21.4% (p max和眼球Dmean均为p  0.05)。与B-OFF相比,B-L&E使MUs提高17.9%,BOT提高58 s(19.0%)。所有计划的伽玛通过率(3%/2 mm)均超过90%,符合美国物理学家协会医学任务组第218号(AAPM TG-218)临床标准。在ENKTCL-NT中,虚拟光束块技术有效地减少了对晶状体和眼球的辐射暴露,同时保持了目标覆盖。B-L&E配置提供最大的桨保护,当需要更短的处理时间时,B-LEN可能更可取。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Dosimetry
Medical Dosimetry 医学-核医学
CiteScore
2.40
自引率
0.00%
发文量
51
审稿时长
34 days
期刊介绍: Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书