Holly K T Huang, Debra W Yen, Michelle Y Li, Gabrielle Jutras, Lisa X Deng, Charles E McCulloch, Mark J Pletcher, Jennifer C Lai, Bilal Hameed, Jin Ge
{"title":"Hepatology e-consult responses generated by artificial intelligence demonstrate accuracy but require human oversight.","authors":"Holly K T Huang, Debra W Yen, Michelle Y Li, Gabrielle Jutras, Lisa X Deng, Charles E McCulloch, Mark J Pletcher, Jennifer C Lai, Bilal Hameed, Jin Ge","doi":"10.1097/HC9.0000000000000983","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Electronic consultations (e-consults) improve specialist access but burden providers. We developed LiVersa, a customized large language model (LLM) for liver diseases. We evaluated its performance in drafting hepatology e-consult responses and the equivalence between human and machine reviewers.</p><p><strong>Methods: </strong>LiVersa-generated responses for hepatology e-consults answered at the University of California San Francisco (UCSF) from January to March 2025. Using a 12-item rubric, 3 independent hepatologists and \"LLM-as-a-judge\" (OpenAI-o1) evaluated drafts against original responses. We tested equivalence between human reviewers and \"LLM-as-a-judge\" using two one-sided tests (TOST).</p><p><strong>Results: </strong>Among 61 e-consults, the most common categories were abnormal liver function tests (34%), hepatitis B (23%), and abnormal imaging (21%). LiVersa drafts demonstrated no differences from hepatologist responses in word count (284 vs. 264, p=0.47) and verbosity (24 vs. 25 words per sentence, p=0.44). Human reviewers rated 72% of drafts as reasonable starting points and 83% as providing appropriate case-specific recommendations; 10% contained misleading/incorrect information, and 3.4% posed a risk of severe harm. LiVersa performed better at avoiding misleading information and extraneous suggestions but scored lower on clinical equivalence, immediate usability, and comprehensiveness. LLM-based reviewers were more stringent than human reviewers, rating fewer drafts as clinically equivalent (27% vs. 48%) and more as potentially harmful (67% vs. 20%), with agreement on accuracy, precision, and comprehensiveness (mean difference 0.026-0.029; TOST p<0.05).</p><p><strong>Conclusions: </strong>Customized LLMs like LiVersa show promise for e-consult drafting but require human oversight. LLM-as-a-judge was more conservative than humans, supporting its role in rapid quality assurance during model updates.</p>","PeriodicalId":12978,"journal":{"name":"Hepatology Communications","volume":"10 7","pages":""},"PeriodicalIF":6.0000,"publicationDate":"2026-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13286463/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hepatology Communications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HC9.0000000000000983","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Electronic consultations (e-consults) improve specialist access but burden providers. We developed LiVersa, a customized large language model (LLM) for liver diseases. We evaluated its performance in drafting hepatology e-consult responses and the equivalence between human and machine reviewers.
Methods: LiVersa-generated responses for hepatology e-consults answered at the University of California San Francisco (UCSF) from January to March 2025. Using a 12-item rubric, 3 independent hepatologists and "LLM-as-a-judge" (OpenAI-o1) evaluated drafts against original responses. We tested equivalence between human reviewers and "LLM-as-a-judge" using two one-sided tests (TOST).
Results: Among 61 e-consults, the most common categories were abnormal liver function tests (34%), hepatitis B (23%), and abnormal imaging (21%). LiVersa drafts demonstrated no differences from hepatologist responses in word count (284 vs. 264, p=0.47) and verbosity (24 vs. 25 words per sentence, p=0.44). Human reviewers rated 72% of drafts as reasonable starting points and 83% as providing appropriate case-specific recommendations; 10% contained misleading/incorrect information, and 3.4% posed a risk of severe harm. LiVersa performed better at avoiding misleading information and extraneous suggestions but scored lower on clinical equivalence, immediate usability, and comprehensiveness. LLM-based reviewers were more stringent than human reviewers, rating fewer drafts as clinically equivalent (27% vs. 48%) and more as potentially harmful (67% vs. 20%), with agreement on accuracy, precision, and comprehensiveness (mean difference 0.026-0.029; TOST p<0.05).
Conclusions: Customized LLMs like LiVersa show promise for e-consult drafting but require human oversight. LLM-as-a-judge was more conservative than humans, supporting its role in rapid quality assurance during model updates.
背景:电子咨询(e-consults)改善了专家的访问,但增加了提供者的负担。我们开发了LiVersa,这是一种针对肝脏疾病定制的大型语言模型(LLM)。我们评估了它在起草肝病电子咨询反应方面的表现以及人类和机器审稿人之间的等效性。方法:从2025年1月到3月,加州大学旧金山分校(UCSF)肝病电子咨询师回答了由liversa产生的应答。三位独立的肝病学家和“法学硕士作为法官”(openai - 01)使用12项标准对草稿和原始回复进行了评估。我们使用两个单侧检验(TOST)测试了人类审稿人和“法学硕士作为法官”之间的等效性。结果:在61位电子会诊者中,最常见的类别是肝功能检查异常(34%)、乙型肝炎(23%)和影像学异常(21%)。LiVersa草稿在字数(284 vs 264, p=0.47)和篇幅(每句24 vs 25个单词,p=0.44)方面与肝病学家的反应没有差异。人工审稿人认为72%的草案是合理的起点,83%的草案提供了适当的具体案例建议;10%包含误导性/不正确的信息,3.4%构成严重伤害的风险。LiVersa在避免误导信息和无关建议方面表现更好,但在临床等效性、即时可用性和全面性方面得分较低。基于法学硕士的审稿人比人工审稿人更严格,较少的草稿被评为临床等效(27%对48%),更多的草稿被评为潜在有害(67%对20%),在准确性、精密度和全面性方面达成一致(平均差异为0.026-0.029)。结论:像LiVersa这样的定制法学硕士显示出电子咨询起草的希望,但需要人工监督。法学硕士作为法官比人类更保守,支持其在模型更新期间快速质量保证中的作用。
期刊介绍:
Hepatology Communications is a peer-reviewed, online-only, open access journal for fast dissemination of high quality basic, translational, and clinical research in hepatology. Hepatology Communications maintains high standard and rigorous peer review. Because of its open access nature, authors retain the copyright to their works, all articles are immediately available and free to read and share, and it is fully compliant with funder and institutional mandates. The journal is committed to fast publication and author satisfaction.