A comprehensive inference-time augmentation framework in physiological signals: application to PPG-based AF detection.

IF 2.5 4区 医学 Q3 BIOPHYSICS
Davood Fattahi, Runze Yan, Saurabh Kataria, Zhaoliang Chen, Xiao Hu
{"title":"A comprehensive inference-time augmentation framework in physiological signals: application to PPG-based AF detection.","authors":"Davood Fattahi, Runze Yan, Saurabh Kataria, Zhaoliang Chen, Xiao Hu","doi":"10.1088/1361-6579/ae7d82","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Accurate classification of physiological signals in real-world deployments is challenged by sensor noise, motion artifacts, and distribution shifts between training and deployment data. Inference-time augmentation (ITA), which applies augmentations during inference rather than retraining, offers a simple, model-agnostic mechanism to improve robustness. However, ITA application to physiological signals has remained narrow in scope, relying on limited augmentation methods with fixed, unoptimized parameters. This work proposes a unified ITA framework to address that gap.<i>Approach.</i>The framework incorporates 13 augmentation methods spanning time-domain, amplitude-domain, frequency-domain, and artifact-injection transformations, with hyperparameters systematically optimized via Bayesian optimization. We evaluate the framework on atrial fibrillation (AF) detection from 30 s photoplethysmography (PPG) signals using two deep learning architectures, generative pre-trained transformer (GPT)-PPG (in two sizes) and ResNet, across five datasets comprising more than 400 patients and ∼9800 h of PPG recording. Two evaluation strategies are assessed: standard ITA applied to all inputs, and selective ITA applied to initially positive predictions.<i>Main results.</i>Standard ITA consistently improved the area under the receiver operating characteristic curve (AUROC, up to 8.5% for GPT-PPG and 0.7% for ResNet) and the area under the precision-recall curve (AUPRC, up to 10.6% for GPT-PPG and 0.8% for ResNet) across all model-dataset combinations. Selective ITA further reduced average FPR by up to 4.4% (GPT-PPG) and 1.3% (ResNet) on non-AF PPG datasets.<i>Significance.</i>These findings establish ITA as a practical, model-agnostic approach for improving the reliability of PPG-based AF classification in deployment settings where retraining is not feasible, with broader applicability to physiological signal analysis.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ae7d82","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.Accurate classification of physiological signals in real-world deployments is challenged by sensor noise, motion artifacts, and distribution shifts between training and deployment data. Inference-time augmentation (ITA), which applies augmentations during inference rather than retraining, offers a simple, model-agnostic mechanism to improve robustness. However, ITA application to physiological signals has remained narrow in scope, relying on limited augmentation methods with fixed, unoptimized parameters. This work proposes a unified ITA framework to address that gap.Approach.The framework incorporates 13 augmentation methods spanning time-domain, amplitude-domain, frequency-domain, and artifact-injection transformations, with hyperparameters systematically optimized via Bayesian optimization. We evaluate the framework on atrial fibrillation (AF) detection from 30 s photoplethysmography (PPG) signals using two deep learning architectures, generative pre-trained transformer (GPT)-PPG (in two sizes) and ResNet, across five datasets comprising more than 400 patients and ∼9800 h of PPG recording. Two evaluation strategies are assessed: standard ITA applied to all inputs, and selective ITA applied to initially positive predictions.Main results.Standard ITA consistently improved the area under the receiver operating characteristic curve (AUROC, up to 8.5% for GPT-PPG and 0.7% for ResNet) and the area under the precision-recall curve (AUPRC, up to 10.6% for GPT-PPG and 0.8% for ResNet) across all model-dataset combinations. Selective ITA further reduced average FPR by up to 4.4% (GPT-PPG) and 1.3% (ResNet) on non-AF PPG datasets.Significance.These findings establish ITA as a practical, model-agnostic approach for improving the reliability of PPG-based AF classification in deployment settings where retraining is not feasible, with broader applicability to physiological signal analysis.

生理信号的综合推理时间增强框架:在基于ppg的AF检测中的应用。
目的:在真实世界的部署中,准确分类生理信号受到传感器噪声、运动伪影以及训练和部署数据之间分布变化的挑战。推理时间增强(ITA)在推理而不是再训练期间应用增强,它提供了一种简单的、与模型无关的机制来提高鲁棒性。然而,ITA在生理信号中的应用范围仍然很窄,依赖于有限的增强方法和固定的、未经优化的参数。这项工作提出了一个统一的ITA框架来解决这一差距。方法:该框架包含13种增强方法,跨越时域、幅域、频域和伪影注入变换,并通过贝叶斯优化系统地优化了超参数。我们使用两种深度学习架构,GPT-PPG(两种尺寸)和ResNet,在包括400多名患者和约9,800小时PPG记录的五个数据集上,评估了从30秒光容积脉搏波(PPG)信号中检测房颤(AF)的框架。评估了两种评估策略:适用于所有输入的标准ITA和适用于最初积极预测的选择性ITA。主要结果:标准ITA在所有模型-数据集组合中持续改善了接收者工作特征曲线下的面积(AUROC, GPT-PPG高达8.5%,ResNet为0.7%)和精度-召回曲线下的面积(AUPRC, GPT-PPG高达10.6%,ResNet为0.8%)。选择性ITA进一步将非AF PPG数据集的平均FPR降低了4.4% (GPT-PPG)和1.3% (ResNet)。意义:这些研究结果表明,ITA是一种实用的、模型无关的方法,可在无法进行再训练的部署环境中提高基于PPG的AF分类的可靠性,对生理信号分析具有更广泛的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological measurement
Physiological measurement 生物-工程:生物医学
CiteScore
5.50
自引率
9.40%
发文量
124
审稿时长
3 months
期刊介绍: Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation. Papers are published on topics including: applied physiology in illness and health electrical bioimpedance, optical and acoustic measurement techniques advanced methods of time series and other data analysis biomedical and clinical engineering in-patient and ambulatory monitoring point-of-care technologies novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems. measurements in molecular, cellular and organ physiology and electrophysiology physiological modeling and simulation novel biomedical sensors, instruments, devices and systems measurement standards and guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书