Davood Fattahi, Runze Yan, Saurabh Kataria, Zhaoliang Chen, Xiao Hu
{"title":"A comprehensive inference-time augmentation framework in physiological signals: application to PPG-based AF detection.","authors":"Davood Fattahi, Runze Yan, Saurabh Kataria, Zhaoliang Chen, Xiao Hu","doi":"10.1088/1361-6579/ae7d82","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Accurate classification of physiological signals in real-world deployments is challenged by sensor noise, motion artifacts, and distribution shifts between training and deployment data. Inference-time augmentation (ITA), which applies augmentations during inference rather than retraining, offers a simple, model-agnostic mechanism to improve robustness. However, ITA application to physiological signals has remained narrow in scope, relying on limited augmentation methods with fixed, unoptimized parameters. This work proposes a unified ITA framework to address that gap.<i>Approach.</i>The framework incorporates 13 augmentation methods spanning time-domain, amplitude-domain, frequency-domain, and artifact-injection transformations, with hyperparameters systematically optimized via Bayesian optimization. We evaluate the framework on atrial fibrillation (AF) detection from 30 s photoplethysmography (PPG) signals using two deep learning architectures, generative pre-trained transformer (GPT)-PPG (in two sizes) and ResNet, across five datasets comprising more than 400 patients and ∼9800 h of PPG recording. Two evaluation strategies are assessed: standard ITA applied to all inputs, and selective ITA applied to initially positive predictions.<i>Main results.</i>Standard ITA consistently improved the area under the receiver operating characteristic curve (AUROC, up to 8.5% for GPT-PPG and 0.7% for ResNet) and the area under the precision-recall curve (AUPRC, up to 10.6% for GPT-PPG and 0.8% for ResNet) across all model-dataset combinations. Selective ITA further reduced average FPR by up to 4.4% (GPT-PPG) and 1.3% (ResNet) on non-AF PPG datasets.<i>Significance.</i>These findings establish ITA as a practical, model-agnostic approach for improving the reliability of PPG-based AF classification in deployment settings where retraining is not feasible, with broader applicability to physiological signal analysis.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ae7d82","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.Accurate classification of physiological signals in real-world deployments is challenged by sensor noise, motion artifacts, and distribution shifts between training and deployment data. Inference-time augmentation (ITA), which applies augmentations during inference rather than retraining, offers a simple, model-agnostic mechanism to improve robustness. However, ITA application to physiological signals has remained narrow in scope, relying on limited augmentation methods with fixed, unoptimized parameters. This work proposes a unified ITA framework to address that gap.Approach.The framework incorporates 13 augmentation methods spanning time-domain, amplitude-domain, frequency-domain, and artifact-injection transformations, with hyperparameters systematically optimized via Bayesian optimization. We evaluate the framework on atrial fibrillation (AF) detection from 30 s photoplethysmography (PPG) signals using two deep learning architectures, generative pre-trained transformer (GPT)-PPG (in two sizes) and ResNet, across five datasets comprising more than 400 patients and ∼9800 h of PPG recording. Two evaluation strategies are assessed: standard ITA applied to all inputs, and selective ITA applied to initially positive predictions.Main results.Standard ITA consistently improved the area under the receiver operating characteristic curve (AUROC, up to 8.5% for GPT-PPG and 0.7% for ResNet) and the area under the precision-recall curve (AUPRC, up to 10.6% for GPT-PPG and 0.8% for ResNet) across all model-dataset combinations. Selective ITA further reduced average FPR by up to 4.4% (GPT-PPG) and 1.3% (ResNet) on non-AF PPG datasets.Significance.These findings establish ITA as a practical, model-agnostic approach for improving the reliability of PPG-based AF classification in deployment settings where retraining is not feasible, with broader applicability to physiological signal analysis.
期刊介绍:
Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation.
Papers are published on topics including:
applied physiology in illness and health
electrical bioimpedance, optical and acoustic measurement techniques
advanced methods of time series and other data analysis
biomedical and clinical engineering
in-patient and ambulatory monitoring
point-of-care technologies
novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems.
measurements in molecular, cellular and organ physiology and electrophysiology
physiological modeling and simulation
novel biomedical sensors, instruments, devices and systems
measurement standards and guidelines.