Patient-Specific 3D-Printed Reference Rod for "Smiley Face Rod" Repair of Lumbar Spondylolysis in a Patient with High Body Mass Index.

IF 1.6 Q3 SURGERY
Spine Surgery and Related Research Pub Date : 2026-03-07 eCollection Date: 2026-05-27 DOI:10.22603/ssrr.2025-0418
Takayuki Kitahara, Masatoshi Morimoto, Naoto Ono, Takafumi Ohshima, Yuji Nagao, Saori Soeda, Daiki Nakajima, Makoto Takeuchi, Hiroshi Kageyama, Junzo Fujitani, Hiroaki Manabe, Fumitake Tezuka, Koichi Sairyo
{"title":"Patient-Specific 3D-Printed Reference Rod for \"Smiley Face Rod\" Repair of Lumbar Spondylolysis in a Patient with High Body Mass Index.","authors":"Takayuki Kitahara, Masatoshi Morimoto, Naoto Ono, Takafumi Ohshima, Yuji Nagao, Saori Soeda, Daiki Nakajima, Makoto Takeuchi, Hiroshi Kageyama, Junzo Fujitani, Hiroaki Manabe, Fumitake Tezuka, Koichi Sairyo","doi":"10.22603/ssrr.2025-0418","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The \"Smiley Face Rod\" (SFR) method is an effective direct repair technique for lumbar spondylolysis. However, three-dimensional rod contouring is technically demanding, particularly in patients with a high body mass index (BMI), where deep soft tissue obscures anatomical landmarks.</p><p><strong>Technical note: </strong>We report a technique using a patient-specific three-dimensional (3D)-printed model to create a sterilized \"Reference Rod\" template. A 27-year-old male with bilateral L5 spondylolysis and severe obesity (BMI 39.8 kg/m<sup>2</sup>) underwent SFR repair. A 3D model was printed from preoperative computed tomography data. A malleable template rod was contoured on this model to perfectly fit the lamina and spinous process and then sterilized. Intraoperatively, the final titanium rod was bent to match this sterile Reference Rod. This allowed for a \"one-pass\" insertion through the interspinous ligament with optimal bony contact, eliminating intraoperative trial-and-error.</p><p><strong>Conclusions: </strong>The 3D-printed Reference Rod technique is a feasible approach that may facilitate rod contouring for SFR in challenging high-BMI cases by providing a tangible template to address the visualization and geometric limitations of conventional fluoroscopy.</p>","PeriodicalId":22253,"journal":{"name":"Spine Surgery and Related Research","volume":"10 3","pages":"511-515"},"PeriodicalIF":1.6000,"publicationDate":"2026-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13255105/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spine Surgery and Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22603/ssrr.2025-0418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/27 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The "Smiley Face Rod" (SFR) method is an effective direct repair technique for lumbar spondylolysis. However, three-dimensional rod contouring is technically demanding, particularly in patients with a high body mass index (BMI), where deep soft tissue obscures anatomical landmarks.

Technical note: We report a technique using a patient-specific three-dimensional (3D)-printed model to create a sterilized "Reference Rod" template. A 27-year-old male with bilateral L5 spondylolysis and severe obesity (BMI 39.8 kg/m2) underwent SFR repair. A 3D model was printed from preoperative computed tomography data. A malleable template rod was contoured on this model to perfectly fit the lamina and spinous process and then sterilized. Intraoperatively, the final titanium rod was bent to match this sterile Reference Rod. This allowed for a "one-pass" insertion through the interspinous ligament with optimal bony contact, eliminating intraoperative trial-and-error.

Conclusions: The 3D-printed Reference Rod technique is a feasible approach that may facilitate rod contouring for SFR in challenging high-BMI cases by providing a tangible template to address the visualization and geometric limitations of conventional fluoroscopy.

“笑脸棒”修复高体重指数患者腰椎峡部裂的患者特异性3d打印参考棒
简介:“笑脸棒”(SFR)法是一种有效的腰椎峡部裂直接修复技术。然而,三维棒轮廓在技术上要求很高,特别是对于身体质量指数(BMI)高的患者,其深层软组织模糊了解剖标志。技术说明:我们报告了一种使用患者特定的三维(3D)打印模型来创建消毒“参考棒”模板的技术。一名27岁男性双侧L5峡部裂和严重肥胖(BMI 39.8 kg/m2)接受了SFR修复。根据术前计算机断层扫描数据打印3D模型。在此模型上勾画出可塑模板棒,以完美贴合椎板和棘突,然后进行灭菌。术中,最终的钛棒弯曲以匹配无菌参考棒。这使得通过棘间韧带的“一次通过”插入具有最佳的骨接触,消除了术中反复试验。结论:3d打印参考棒技术是一种可行的方法,可以通过提供一个有形的模板来解决传统透视的可视化和几何限制,从而促进高bmi病例SFR的棒轮廓。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
71
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书