How few channels suffice? A hierarchical validation framework for minimal-channel wearable sEMG in upper-limb rehabilitation gesture recognition.

IF 6 2区 医学 Q1 ENGINEERING, BIOMEDICAL
Xiangyang Li, Huayue Liu, Aoying Shangguan, Huanghe Zhang
{"title":"How few channels suffice? A hierarchical validation framework for minimal-channel wearable sEMG in upper-limb rehabilitation gesture recognition.","authors":"Xiangyang Li, Huayue Liu, Aoying Shangguan, Huanghe Zhang","doi":"10.1186/s12984-026-02039-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Surface electromyography (sEMG) is widely adopted in upper-limb rehabilitation for decoding motor intent. However, current wearable systems typically require eight or more channels, imposing penalties on device complexity, power consumption, and patient comfort. Reducing channel count without sacrificing recognition accuracy remains an open challenge for user-independent rehabilitation scenarios. We hypothesize that systematically optimizing channel configurations under high-fidelity acquisition conditions can identify a minimal viable topology suitable for clinical deployment.</p><p><strong>Methods: </strong>We present a hierarchical validation framework integrating three pillars of evidence. First, we developed a custom acquisition system achieving a common-mode rejection ratio exceeding 112 dB, ensuring that observed inter-channel differences reflect physiology rather than hardware artifacts. Second, we performed an exhaustive subset search across all 63 non-empty combinations of six channels in 24 healthy subjects under leave-one-subject-out (LOSO) cross-validation. Third, a dual-track sensitivity analysis was conducted by training on physiologically augmented data while testing under hardware-degraded conditions.</p><p><strong>Results: </strong>Results reveal a tiered structure: the 3-channel configuration serves as the efficiency knee point (91.65%), exceeding the 90% clinical reliability threshold, although its cross-subject generalizability is limited by a maximum regret of 10.5% and only 8/24 subjects achieving zero regret under the global 3-channel topology. The 4-channel configuration acts as the recommended optimal (94.44%), eliminating worst-case blind spots ([Formula: see text]). An overlap ratio analysis confirms high alignment between global and individual optima, with 67% of subjects achieving zero regret under the global 4-channel topology. The dual-track sensitivity analysis demonstrates a 16% robustness gain under low-SNR conditions, validating that high-fidelity acquisition is the functional prerequisite for channel reduction.</p><p><strong>Conclusions: </strong>Within the six-site candidate pool studied here, the globally fixed 4-channel topology achieved performance close to the 6-channel baseline under rigorous LOSO validation. While the 3-channel configuration meets the 90% clinical threshold on average, its substantial inter-subject regret (up to 10.5%) limits its suitability as a universal solution. The optimal 4-channel topology converges on four forearm muscles spanning the wrist's two kinematic degrees of freedom, providing an anatomically grounded, patient-independent design principle. These findings offer a practical pathway toward lightweight, comfortable, and clinically viable rehabilitation interfaces that could improve patient compliance and therapeutic outcomes.</p>","PeriodicalId":16384,"journal":{"name":"Journal of NeuroEngineering and Rehabilitation","volume":" ","pages":""},"PeriodicalIF":6.0000,"publicationDate":"2026-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13504779/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NeuroEngineering and Rehabilitation","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1186/s12984-026-02039-x","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Surface electromyography (sEMG) is widely adopted in upper-limb rehabilitation for decoding motor intent. However, current wearable systems typically require eight or more channels, imposing penalties on device complexity, power consumption, and patient comfort. Reducing channel count without sacrificing recognition accuracy remains an open challenge for user-independent rehabilitation scenarios. We hypothesize that systematically optimizing channel configurations under high-fidelity acquisition conditions can identify a minimal viable topology suitable for clinical deployment.

Methods: We present a hierarchical validation framework integrating three pillars of evidence. First, we developed a custom acquisition system achieving a common-mode rejection ratio exceeding 112 dB, ensuring that observed inter-channel differences reflect physiology rather than hardware artifacts. Second, we performed an exhaustive subset search across all 63 non-empty combinations of six channels in 24 healthy subjects under leave-one-subject-out (LOSO) cross-validation. Third, a dual-track sensitivity analysis was conducted by training on physiologically augmented data while testing under hardware-degraded conditions.

Results: Results reveal a tiered structure: the 3-channel configuration serves as the efficiency knee point (91.65%), exceeding the 90% clinical reliability threshold, although its cross-subject generalizability is limited by a maximum regret of 10.5% and only 8/24 subjects achieving zero regret under the global 3-channel topology. The 4-channel configuration acts as the recommended optimal (94.44%), eliminating worst-case blind spots ([Formula: see text]). An overlap ratio analysis confirms high alignment between global and individual optima, with 67% of subjects achieving zero regret under the global 4-channel topology. The dual-track sensitivity analysis demonstrates a 16% robustness gain under low-SNR conditions, validating that high-fidelity acquisition is the functional prerequisite for channel reduction.

Conclusions: Within the six-site candidate pool studied here, the globally fixed 4-channel topology achieved performance close to the 6-channel baseline under rigorous LOSO validation. While the 3-channel configuration meets the 90% clinical threshold on average, its substantial inter-subject regret (up to 10.5%) limits its suitability as a universal solution. The optimal 4-channel topology converges on four forearm muscles spanning the wrist's two kinematic degrees of freedom, providing an anatomically grounded, patient-independent design principle. These findings offer a practical pathway toward lightweight, comfortable, and clinically viable rehabilitation interfaces that could improve patient compliance and therapeutic outcomes.

多少个频道就够了?用于上肢康复手势识别的最小通道可穿戴表面肌电信号分层验证框架。
背景:表面肌电图(sEMG)被广泛应用于上肢康复中,用于解码运动意图。然而,目前的可穿戴系统通常需要8个或更多的通道,这对设备的复杂性、功耗和患者舒适度造成了不利影响。在不牺牲识别准确性的情况下减少信道数仍然是用户独立康复方案的一个开放挑战。我们假设在高保真采集条件下系统地优化通道配置可以确定适合临床部署的最小可行拓扑。方法:我们提出了一个整合三个证据支柱的分层验证框架。首先,我们开发了一个定制采集系统,实现了超过112 dB的共模抑制比,确保观察到的信道间差异反映了生理而不是硬件人为因素。其次,我们在24名健康受试者的6个通道的63个非空组合中进行了彻底的子集搜索,并进行了遗漏一个受试者(LOSO)交叉验证。第三,在硬件退化条件下进行测试时,对生理增强数据进行训练,进行双轨灵敏度分析。结果:结果呈现分层结构:3通道配置作为效率膝点(91.65%),超过90%的临床信度阈值,但其跨受试者推广受到最大后悔10.5%的限制,只有8/24的受试者在全局3通道拓扑下实现零后悔。4通道配置作为推荐的最佳(94.44%),消除了最坏情况下的盲点([公式:见文本])。重叠率分析证实了全局和个体最优之间的高度一致性,67%的受试者在全局4通道拓扑结构下实现零遗憾。双轨灵敏度分析表明,在低信噪比条件下,稳健性增益为16%,验证了高保真采集是信道减少的功能先决条件。结论:在这里研究的六个站点候选池中,在严格的LOSO验证下,全局固定的4通道拓扑实现了接近6通道基线的性能。虽然3通道配置平均达到90%的临床阈值,但其大量的主体间后悔(高达10.5%)限制了其作为通用解决方案的适用性。最佳的4通道拓扑结构集中在跨越手腕两个运动自由度的四个前臂肌肉上,提供了解剖学基础,与患者无关的设计原则。这些发现为轻质、舒适和临床可行的康复界面提供了一条实用的途径,可以提高患者的依从性和治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of NeuroEngineering and Rehabilitation
Journal of NeuroEngineering and Rehabilitation 工程技术-工程:生物医学
CiteScore
9.60
自引率
3.90%
发文量
122
审稿时长
24 months
期刊介绍: Journal of NeuroEngineering and Rehabilitation considers manuscripts on all aspects of research that result from cross-fertilization of the fields of neuroscience, biomedical engineering, and physical medicine & rehabilitation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书