Research of Corrosion Resistance of Titanium Nickelide Rods in Spinal Pedicle Screw Devices with Various Fixation Types

IF 2.2 4区 材料科学 Q2 MATERIALS SCIENCE, CHARACTERIZATION & TESTING
E. A. Lukina, E. V. Preobrazhenskii, D. E. Gusev
{"title":"Research of Corrosion Resistance of Titanium Nickelide Rods in Spinal Pedicle Screw Devices with Various Fixation Types","authors":"E. A. Lukina,&nbsp;E. V. Preobrazhenskii,&nbsp;D. E. Gusev","doi":"10.1134/S1029959925600211","DOIUrl":null,"url":null,"abstract":"<p>In this work, the finite element method is used for numerical calculation of the stress and strain distribution on the surface of TiNi-based alloy spinal rods locked in pedicle screw constructs with various geometries of fastening elements, and an experimental study of their corrosion resistance is carried out using long–term immersion test into a 0.9% NaCl corrosion solution and fretting corrosion test by applying a cyclic load with a bending moment arising during functional movements in the lumbar spine. It has been revealed that the formation of local plastic deformation zones during initial locking and following cyclic loading, the surface area (<i>S</i>) and the maximum degree of deformation (ε<sub>plast (max)</sub>) in which depend on the geometry of pedicle screw fastening elements, has a significant negative effect on the corrosion resistance of TiNi rods in the studied constructs. The corrosion damage of TiNi rods after long–term immersion test was revealed when using only one type of pedicle screws which causing the formation of plastic deformation zones on the rods surface at the initial stage of rods locking. It has been shown that the fretting corrosion current decreases from 5.8 ± 3 μA to 1.3 ± 0.4 μA, the area of corrosion damage decreases from 0.23 ± 0.04 to 0.015 ± 0.01 mm<sup>2</sup>, and the content of Ni ions in the corrosive environment reduces by 2.9-fold when testing in screws with fastening elements leading to the formation of local plastic deformation zones with ε<sub>plast (max) (I)</sub> = 62%; <i>S</i><sub>(I)</sub> = 7.7 mm<sup>2</sup> and ε<sub>plast (max) (II)</sub> = 3.7%; <i>S</i><sub>(II)</sub> = 4.9 mm<sup>2</sup>, respectively. It has been demonstrated that the application of the third type of pedicle screws with the fastening elements which do not lead to the formation of plastic deformation zones on TiNi rods surface at initial locking and during the subsequent application of cyclic load, completely prevents the development of the corrosion process, indicating the need to select the optimal geometry of the fastening elements to ensure high reliability and durability of medical implant constructs with components made of TiNi-based alloys.</p>","PeriodicalId":726,"journal":{"name":"Physical Mesomechanics","volume":"29 3","pages":"435 - 450"},"PeriodicalIF":2.2000,"publicationDate":"2026-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical Mesomechanics","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1134/S1029959925600211","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, the finite element method is used for numerical calculation of the stress and strain distribution on the surface of TiNi-based alloy spinal rods locked in pedicle screw constructs with various geometries of fastening elements, and an experimental study of their corrosion resistance is carried out using long–term immersion test into a 0.9% NaCl corrosion solution and fretting corrosion test by applying a cyclic load with a bending moment arising during functional movements in the lumbar spine. It has been revealed that the formation of local plastic deformation zones during initial locking and following cyclic loading, the surface area (S) and the maximum degree of deformation (εplast (max)) in which depend on the geometry of pedicle screw fastening elements, has a significant negative effect on the corrosion resistance of TiNi rods in the studied constructs. The corrosion damage of TiNi rods after long–term immersion test was revealed when using only one type of pedicle screws which causing the formation of plastic deformation zones on the rods surface at the initial stage of rods locking. It has been shown that the fretting corrosion current decreases from 5.8 ± 3 μA to 1.3 ± 0.4 μA, the area of corrosion damage decreases from 0.23 ± 0.04 to 0.015 ± 0.01 mm2, and the content of Ni ions in the corrosive environment reduces by 2.9-fold when testing in screws with fastening elements leading to the formation of local plastic deformation zones with εplast (max) (I) = 62%; S(I) = 7.7 mm2 and εplast (max) (II) = 3.7%; S(II) = 4.9 mm2, respectively. It has been demonstrated that the application of the third type of pedicle screws with the fastening elements which do not lead to the formation of plastic deformation zones on TiNi rods surface at initial locking and during the subsequent application of cyclic load, completely prevents the development of the corrosion process, indicating the need to select the optimal geometry of the fastening elements to ensure high reliability and durability of medical implant constructs with components made of TiNi-based alloys.

Abstract Image

不同固定方式椎弓根螺钉装置中镍化钛棒的耐腐蚀性能研究
本文采用有限元方法,对不同紧固元件几何形状的椎弓根螺钉结构中锁紧的ti基合金椎弓根表面的应力应变分布进行了数值计算。采用0.9% NaCl腐蚀溶液长期浸泡试验和腰椎功能运动中产生弯矩的循环载荷微动腐蚀试验,对其耐腐蚀性能进行了实验研究。研究表明,在初始锁定和循环加载过程中,局部塑性变形区域的形成,取决于椎弓根螺钉紧固元件几何形状的表面积(S)和最大变形程度(εplast (max))对研究结构中TiNi棒的耐腐蚀性有显著的负面影响。仅使用一种椎弓根螺钉时,经长期浸渍试验后的TiNi棒存在腐蚀损伤,使杆在锁紧初期表面形成塑性变形区。结果表明:在带有紧固元件的螺钉中,微动腐蚀电流从5.8±3 μA减小到1.3±0.4 μA,腐蚀损伤面积从0.23±0.04 mm2减小到0.015±0.01 mm2,腐蚀环境中Ni离子含量减少了2.9倍,形成了ε塑性(max) (I) = 62%的局部塑性变形区;S(I) = 7.7 mm2, ε plasast (max) (II) = 3.7%;S(II) = 4.9 mm2。已经证明,应用第三种类型的椎弓根螺钉,其紧固元件在初始锁定和随后的循环载荷施加期间不会导致TiNi棒表面形成塑性变形区,完全阻止了腐蚀过程的发展。这表明需要选择最佳的紧固元件几何形状,以确保使用钛基合金制成的医疗植入物结构的高可靠性和耐用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physical Mesomechanics
Physical Mesomechanics Materials Science-General Materials Science
CiteScore
3.50
自引率
18.80%
发文量
48
期刊介绍: The journal provides an international medium for the publication of theoretical and experimental studies and reviews related in the physical mesomechanics and also solid-state physics, mechanics, materials science, geodynamics, non-destructive testing and in a large number of other fields where the physical mesomechanics may be used extensively. Papers dealing with the processing, characterization, structure and physical properties and computational aspects of the mesomechanics of heterogeneous media, fracture mesomechanics, physical mesomechanics of materials, mesomechanics applications for geodynamics and tectonics, mesomechanics of smart materials and materials for electronics, non-destructive testing are viewed as suitable for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书