{"title":"Noise quantification in the intensive care unit of a tertiary care hospital.","authors":"Ruchi Gupta, Arshdeep S Chadha, Himanshi Lakra, Rimsha Rehan, Raminder Kalra, Sumit Ray","doi":"10.5492/wjccm.v15.i2.114240","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Noise in intensive care units (ICUs) frequently exceeds recommended levels [the World Health Organization (WHO) recommends equivalent continuous noise level (Leq) < 35 dB], arising from alarms, equipment, and staff activity. Elevated sound can disrupt patients' sleep, increase stress, and impair recovery.</p><p><strong>Aim: </strong>To identify the extent of noise exposure in the ICU.</p><p><strong>Methods: </strong>This observational study was conducted in the adult ICU of a tertiary care hospital. Noise was measured using the SERRAX SLM1090 sound level meter, which was placed in the center of the 10-bed ICU at a height of 6 feet above ground level. A 30-minute time window was set to obtain half-hourly Leq, L10, L50, L90 (representing sound levels exceeding 10%, 50%, and 90% of the time, respectively), and maximum sound level (Lmax).</p><p><strong>Results: </strong>Data were collected over 4 months (December 2024 to March 2025), yielding 5443 half-hourly recordings. The average Leq, Lmax, L10, L50, L90 and sound exposure level were 64.8 ± 2.8 dB, 82.5 ± 4.4 dB, 67.5 ± 2.9 dB, 61.4 ± 3.2 dB, 56.4 ± 2.8 dB and 97.7 ± 2.8 dB, respectively. Nurses' handover, visitation and twilight hours were the noisiest. Nighttime (1:00 hours to 3:00 hours) was the quietest in the ICU. Lmax in the ICU exceeded the WHO cut-offs for industrial sounds and public addresses of 75 dB and 85 dB in 96.7% and 25.5% of readings, respectively. Twenty-four-hour cumulative sound exposure to the patient for night and evening-night penalties were 68 dB and 70 dB, respectively.</p><p><strong>Conclusion: </strong>The noise exposure in the ICU persistently exceeded WHO-recommended thresholds. Maximum noise occurred during handovers, visitation and twilight activities, indicating that these times would be the most effective for intervention.</p>","PeriodicalId":66959,"journal":{"name":"世界危重病急救学杂志(英文版)","volume":"15 2","pages":"114240"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13248028/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"世界危重病急救学杂志(英文版)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5492/wjccm.v15.i2.114240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Noise in intensive care units (ICUs) frequently exceeds recommended levels [the World Health Organization (WHO) recommends equivalent continuous noise level (Leq) < 35 dB], arising from alarms, equipment, and staff activity. Elevated sound can disrupt patients' sleep, increase stress, and impair recovery.

Aim: To identify the extent of noise exposure in the ICU.

Methods: This observational study was conducted in the adult ICU of a tertiary care hospital. Noise was measured using the SERRAX SLM1090 sound level meter, which was placed in the center of the 10-bed ICU at a height of 6 feet above ground level. A 30-minute time window was set to obtain half-hourly Leq, L10, L50, L90 (representing sound levels exceeding 10%, 50%, and 90% of the time, respectively), and maximum sound level (Lmax).

Results: Data were collected over 4 months (December 2024 to March 2025), yielding 5443 half-hourly recordings. The average Leq, Lmax, L10, L50, L90 and sound exposure level were 64.8 ± 2.8 dB, 82.5 ± 4.4 dB, 67.5 ± 2.9 dB, 61.4 ± 3.2 dB, 56.4 ± 2.8 dB and 97.7 ± 2.8 dB, respectively. Nurses' handover, visitation and twilight hours were the noisiest. Nighttime (1:00 hours to 3:00 hours) was the quietest in the ICU. Lmax in the ICU exceeded the WHO cut-offs for industrial sounds and public addresses of 75 dB and 85 dB in 96.7% and 25.5% of readings, respectively. Twenty-four-hour cumulative sound exposure to the patient for night and evening-night penalties were 68 dB and 70 dB, respectively.

Conclusion: The noise exposure in the ICU persistently exceeded WHO-recommended thresholds. Maximum noise occurred during handovers, visitation and twilight activities, indicating that these times would be the most effective for intervention.

某三级医院重症监护室噪声量化研究。
背景:重症监护病房(icu)的噪声经常超过推荐水平[世界卫生组织(WHO)建议等效连续噪声水平(Leq) < 35 dB],由警报、设备和工作人员活动引起。升高的声音会扰乱病人的睡眠,增加压力,损害康复。目的:了解重症监护病房的噪声暴露程度。方法:本观察性研究在某三级医院成人ICU进行。使用SERRAX SLM1090声级计测量噪声,该声级计放置在离地面6英尺高的10张病床的ICU中心。设置一个30分钟的时间窗口,以获得半小时Leq、L10、L50、L90(分别表示超过10%、50%和90%的声级)和最大声级(Lmax)。结果:数据收集时间为4个月(2024年12月至2025年3月),得到5443条半小时记录。平均Leq、Lmax、L10、L50、L90和声暴露水平分别为64.8±2.8 dB、82.5±4.4 dB、67.5±2.9 dB、61.4±3.2 dB、56.4±2.8 dB和97.7±2.8 dB。护士的交接、探视和黄昏时分是最吵的。夜间(1 ~ 3时)是ICU最安静的时间。ICU的Lmax分别在96.7%和25.5%的读数中超过了世界卫生组织对工业声音和公共广播75db和85db的截止值。患者在夜间和夜间的24小时累积声音暴露分别为68分贝和70分贝。结论:ICU噪声暴露持续超过who推荐阈值。最大的噪音发生在交接,探视和黄昏活动期间,表明这些时间将是最有效的干预。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
216
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书