{"title":"Clinical edge-case stress testing of two Asia-developed AI auto-contouring systems using prostate radiotherapy planning CT images.","authors":"Yuya Nagake, Keisuke Yasui, Ayami Sugiyama, Yasunori Saito, Hidetoshi Shimizu, Haruka Uezono, Naoki Hayashi","doi":"10.1007/s12194-026-01080-8","DOIUrl":null,"url":null,"abstract":"<p><p>To compare the geometric accuracy of two Asia‑developed AI auto‑contouring systems (RatoGuide and OncoStudio) for prostate radiotherapy planning CT, including performance in clinical edge cases. Planning CT data from 45 patients were stratified into four groups (Normal, Spacer, Seed/Spacer, GM/Spacer). Manual contours of prostate, rectum, bladder, seminal vesicles, and femoral heads served as reference. Segmentation accuracy was assessed using DSC and 95% Hausdorff distance; Wilcoxon signed‑rank and Mann-Whitney U tests were applied, with edge‑case analyses treated as exploratory. Median DSC exceeded 0.7 for all structures. RatoGuide performed better for the rectum, whereas OncoStudio performed better for the bladder, seminal vesicles, and femoral heads. Outliers were concentrated in combined implant/spacer groups. Both tools showed generally favorable geometric agreement, with structure‑dependent advantages and edge‑case outliers that warrant workflow‑aware quality assurance and future dosimetric validation.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":"1380-1386"},"PeriodicalIF":1.6000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-026-01080-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
To compare the geometric accuracy of two Asia‑developed AI auto‑contouring systems (RatoGuide and OncoStudio) for prostate radiotherapy planning CT, including performance in clinical edge cases. Planning CT data from 45 patients were stratified into four groups (Normal, Spacer, Seed/Spacer, GM/Spacer). Manual contours of prostate, rectum, bladder, seminal vesicles, and femoral heads served as reference. Segmentation accuracy was assessed using DSC and 95% Hausdorff distance; Wilcoxon signed‑rank and Mann-Whitney U tests were applied, with edge‑case analyses treated as exploratory. Median DSC exceeded 0.7 for all structures. RatoGuide performed better for the rectum, whereas OncoStudio performed better for the bladder, seminal vesicles, and femoral heads. Outliers were concentrated in combined implant/spacer groups. Both tools showed generally favorable geometric agreement, with structure‑dependent advantages and edge‑case outliers that warrant workflow‑aware quality assurance and future dosimetric validation.
期刊介绍:
The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.