{"title":"Clinical benefits and current challenges of photon-counting detector CT in vascular imaging.","authors":"Ahmed O El Sadaney, Felix E Diehn, Prabhakar Shantha Rajiah, Ian Mark, Norbert G Campeau, Adam T Froemming, Francis I Baffour, Kelly K Horst, Lifeng Yu, Shuai Leng, Cynthia H McCollough, Joel G Fletcher","doi":"10.1093/radadv/umag021","DOIUrl":null,"url":null,"abstract":"<p><p>Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.</p>","PeriodicalId":519940,"journal":{"name":"Radiology advances","volume":"3 3","pages":"umag021"},"PeriodicalIF":1.8000,"publicationDate":"2026-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13234556/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology advances","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/radadv/umag021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.

光子计数检测器CT在血管成像中的临床益处和当前挑战。
光子计数检测器CT (PCD-CT)直接检测单个光子并测量其能量,从而能够从单个x射线源获取具有更高空间分辨率的多能数据,从而可以可视化较小的动脉和静脉以及传统CT无法看到的其他重要成像特征。它也大大减少了钙和支架开花的工件。适当的患者选择和基于任务的获取、重建和解释优化是实现这些好处的关键。早期证据显示,与传统CT相比,PCD-CT的血管成像检查具有更高的诊断性能,包括用于评估部分钙化斑块或支架的冠状动脉CT血管造影(CTA)、外周径流CTA、检测脑脊液-静脉瘘,以及用于评估颅内小血管和动脉瘤的头部CTA。目前的限制包括最清晰的重建核的图像噪声过大,以及适应传统CT协议(例如,需要更清晰的核,更薄的切片,更高的矩阵,定制的扫描模式)以实现时间高效的图像重建和悬挂协议时的挑战。新的解决方案和方向将包括基于深度学习的图像降噪、改进的光谱分离、对特定患者群体进行PCD-CT系统的战略性分类,以及针对这项新技术的亚专科临床实践建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书