{"title":"Toward a harmonized assessment of MRD by NGS: blinded pilot study of NGS assays by MPAACT consortium.","authors":"Vanessa Obourn, Shalaka Patel, Gonzalo Lopez, Sarah Hersey, Mark Stern, Habib Hamidi","doi":"10.1080/17410541.2026.2682844","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Measurable residual disease (MRD) is a key prognostic factor in acute myeloid leukemia (AML). The Measurable residual disease Partnership and Alliance in Acute Myeloid Leukemia Clinical Treatment (MPAACT) Consortium aims to accelerate AML therapy development by validating MRD as an early clinical trial endpoint within the regulatory framework. This blinded pilot study evaluated commercial next-generation sequencing (NGS) MRD assays to identify those meeting technical, regulatory, and quality criteria for development.</p><p><strong>Methods: </strong>Of 19 vendors meeting eligibility criteria, eight responded and seven assays from six vendors proceeded to blinded testing. Using 45 contrived DNA samples with variant allele frequencies (VAFs) from 0.1% to 15%, MPAACT evaluated sensitivity, specificity, reproducibility, accuracy, and dynamic range at 50 ng and 200 ng DNA inputs from vendor-submitted raw and annotated data.</p><p><strong>Results: </strong>Two assays were eliminated due to inadequate variant detection or gene coverage. Among the remaining five, sensitivity varied and none reliably detected VAFs <0.5%. Increased DNA input improved low-VAF detection but elevated false positives. Assays 3, 4, and 7 showed the strongest performance; Assay 7 had the lowest detection limit but higher false positives.</p><p><strong>Conclusions: </strong>Commercial NGS assay performance varied widely, particularly at low VAFs. Selected assays merit further optimization for MRD assessments.</p>","PeriodicalId":94167,"journal":{"name":"Personalized medicine","volume":" ","pages":"227-234"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Personalized medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17410541.2026.2682844","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/8 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Measurable residual disease (MRD) is a key prognostic factor in acute myeloid leukemia (AML). The Measurable residual disease Partnership and Alliance in Acute Myeloid Leukemia Clinical Treatment (MPAACT) Consortium aims to accelerate AML therapy development by validating MRD as an early clinical trial endpoint within the regulatory framework. This blinded pilot study evaluated commercial next-generation sequencing (NGS) MRD assays to identify those meeting technical, regulatory, and quality criteria for development.

Methods: Of 19 vendors meeting eligibility criteria, eight responded and seven assays from six vendors proceeded to blinded testing. Using 45 contrived DNA samples with variant allele frequencies (VAFs) from 0.1% to 15%, MPAACT evaluated sensitivity, specificity, reproducibility, accuracy, and dynamic range at 50 ng and 200 ng DNA inputs from vendor-submitted raw and annotated data.

Results: Two assays were eliminated due to inadequate variant detection or gene coverage. Among the remaining five, sensitivity varied and none reliably detected VAFs <0.5%. Increased DNA input improved low-VAF detection but elevated false positives. Assays 3, 4, and 7 showed the strongest performance; Assay 7 had the lowest detection limit but higher false positives.

Conclusions: Commercial NGS assay performance varied widely, particularly at low VAFs. Selected assays merit further optimization for MRD assessments.

迈向NGS对MRD的统一评估:由MPAACT联盟进行的NGS检测的盲法先导研究。
背景:可测量残留病(MRD)是急性髓系白血病(AML)预后的关键因素。急性髓系白血病临床治疗可测量残留疾病合作联盟(MPAACT)旨在通过在监管框架内验证MRD作为早期临床试验终点来加速AML治疗的发展。这项盲法试点研究评估了商业化的下一代测序(NGS) MRD分析,以确定那些符合技术、法规和质量标准的开发方法。方法:在符合资格标准的19家供应商中,8家回应,6家供应商的7项测定进行了盲法试验。使用45个变异等位基因频率(VAFs)为0.1%至15%的人造DNA样本,MPAACT评估了供应商提交的原始和注释数据在50 ng和200 ng DNA输入下的灵敏度、特异性、再现性、准确性和动态范围。结果:由于变异检测或基因覆盖不足,两项检测被淘汰。结论:商用NGS检测方法的性能差异很大,特别是在低VAFs时。所选的分析方法值得进一步优化用于MRD评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书