Significance of echocardiographic metrics including TRV and TAPSE/SPAP in mild haemodynamic pulmonary hypertension - data from EVIDENCE-PAH UK.

IF 4.4 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Nina Karia, Daniel Murphy, Luke Howard, Martin Johnson, David G Kiely, James Lordan, Colm McCabe, Joanna Pepke-Zaba, Daniel Knight, Vivek Muthurangu, J Gerry Coghlan
{"title":"Significance of echocardiographic metrics including TRV and TAPSE/SPAP in mild haemodynamic pulmonary hypertension - data from EVIDENCE-PAH UK.","authors":"Nina Karia, Daniel Murphy, Luke Howard, Martin Johnson, David G Kiely, James Lordan, Colm McCabe, Joanna Pepke-Zaba, Daniel Knight, Vivek Muthurangu, J Gerry Coghlan","doi":"10.1186/s44156-026-00119-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The 2022 ESC/ERS guidelines redefined pulmonary hypertension (PH) as a mean pulmonary artery pressure (mPAP) >20 mmHg on right heart catheterisation (RHC). Echocardiography, using metrics such as tricuspid regurgitation velocity (TRV), tricuspid annular plane systolic excursion (TAPSE), and TAPSE/systolic pulmonary artery pressure (TAPSE/SPAP), guides referral for RHC. However, the few studies evaluating echocardiographic performance using the ESC/ERS 2022 thresholds have combined the newly included population as a relatively modest subgroup within their overall analysis.</p><p><strong>Results: </strong>We present a sample of 1,991 individuals from the EVIDENCE-PAH UK database. Our data demonstrate higher TRV and sPAP values and lower TAPSE/SPAP values with higher haemodynamic category. ROC analysis demonstrates that TRV, SPAP and TAPSE/SPAP perform well as predictors of mPAP > 20 mmHg and ≥25 mmHg (AUCs 0.785-0.830), but less well at predictive mPAP 21-24 mmHg (AUCs 0.656-0.686). In all PH patients and the mild PH (21-24 mmHg) subgroup, TAPSE/SPAP < 0.31 mm/mmHg predicted reduced survival (HR 2.01-3.14, p < 0.001). Similarly, in haemodynamically mild PH, TRV > 3.4 m/s was associated with worse survival compared to TRV < 2.5 m/s or 2.5-2.8 m/s (p < 0.001).</p><p><strong>Conclusions: </strong>While established echocardiographic metrics (TRV, TAPSE/SPAP) are strong predictors of significant PH (mPAP ≥25 mmHg), they are less accurate for mild PH (mPAP 21-24 mmHg). Importantly, mild PH itself is associated with increased mortality, and within this group, TRV >3.4 m/s and TAPSE/SPAP <0.31 mm/mmHg identify patients at highest risk, supporting their prognostic utility even in early haemodynamic disease.</p>","PeriodicalId":45749,"journal":{"name":"Echo Research and Practice","volume":"13 1","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2026-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13245079/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Echo Research and Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s44156-026-00119-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The 2022 ESC/ERS guidelines redefined pulmonary hypertension (PH) as a mean pulmonary artery pressure (mPAP) >20 mmHg on right heart catheterisation (RHC). Echocardiography, using metrics such as tricuspid regurgitation velocity (TRV), tricuspid annular plane systolic excursion (TAPSE), and TAPSE/systolic pulmonary artery pressure (TAPSE/SPAP), guides referral for RHC. However, the few studies evaluating echocardiographic performance using the ESC/ERS 2022 thresholds have combined the newly included population as a relatively modest subgroup within their overall analysis.

Results: We present a sample of 1,991 individuals from the EVIDENCE-PAH UK database. Our data demonstrate higher TRV and sPAP values and lower TAPSE/SPAP values with higher haemodynamic category. ROC analysis demonstrates that TRV, SPAP and TAPSE/SPAP perform well as predictors of mPAP > 20 mmHg and ≥25 mmHg (AUCs 0.785-0.830), but less well at predictive mPAP 21-24 mmHg (AUCs 0.656-0.686). In all PH patients and the mild PH (21-24 mmHg) subgroup, TAPSE/SPAP < 0.31 mm/mmHg predicted reduced survival (HR 2.01-3.14, p < 0.001). Similarly, in haemodynamically mild PH, TRV > 3.4 m/s was associated with worse survival compared to TRV < 2.5 m/s or 2.5-2.8 m/s (p < 0.001).

Conclusions: While established echocardiographic metrics (TRV, TAPSE/SPAP) are strong predictors of significant PH (mPAP ≥25 mmHg), they are less accurate for mild PH (mPAP 21-24 mmHg). Importantly, mild PH itself is associated with increased mortality, and within this group, TRV >3.4 m/s and TAPSE/SPAP <0.31 mm/mmHg identify patients at highest risk, supporting their prognostic utility even in early haemodynamic disease.

超声心动图指标包括TRV和TAPSE/SPAP在轻度血流动力学肺动脉高压中的意义——来自EVIDENCE-PAH UK的数据。
背景:2022年ESC/ERS指南将肺动脉高压(PH)重新定义为右心导管(RHC)时的平均肺动脉压(mPAP) bbb20 mmHg。超声心动图,使用指标,如三尖瓣反流速度(TRV),三尖瓣环平面收缩偏移(TAPSE)和TAPSE/收缩期肺动脉压(TAPSE/SPAP),指导RHC的转诊。然而,少数使用ESC/ERS 2022阈值评估超声心动图性能的研究将新纳入的人群作为总体分析中相对温和的亚组。结果:我们从EVIDENCE-PAH UK数据库中提供了1991个个体的样本。我们的数据显示较高的TRV和sPAP值和较低的TAPSE/ sPAP值与较高的血流动力学类别。ROC分析表明,TRV、SPAP和TAPSE/SPAP可以很好地预测mPAP低于20 mmHg和≥25 mmHg (auc 0.785-0.830),但预测mPAP低于21-24 mmHg (auc 0.656-0.686)。在所有PH患者和轻度PH (21-24 mmHg)亚组中,与TRV相比,TAPSE/SPAP 3.4 m/s与更差的生存率相关。结论:虽然建立的超声心动图指标(TRV, TAPSE/SPAP)是显著PH (mPAP≥25 mmHg)的强预测因子,但它们对轻度PH (mPAP 21-24 mmHg)的准确性较低。重要的是,轻度PH本身与死亡率增加有关,在该组中,TRV >3.4 m/s和TAPSE/SPAP
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Echo Research and Practice
Echo Research and Practice CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
6.70
自引率
12.70%
发文量
11
审稿时长
8 weeks
期刊介绍: Echo Research and Practice aims to be the premier international journal for physicians, sonographers, nurses and other allied health professionals practising echocardiography and other cardiac imaging modalities. This open-access journal publishes quality clinical and basic research, reviews, videos, education materials and selected high-interest case reports and videos across all echocardiography modalities and disciplines, including paediatrics, anaesthetics, general practice, acute medicine and intensive care. Multi-modality studies primarily featuring the use of cardiac ultrasound in clinical practice, in association with Cardiac Computed Tomography, Cardiovascular Magnetic Resonance or Nuclear Cardiology are of interest. Topics include, but are not limited to: 2D echocardiography 3D echocardiography Comparative imaging techniques – CCT, CMR and Nuclear Cardiology Congenital heart disease, including foetal echocardiography Contrast echocardiography Critical care echocardiography Deformation imaging Doppler echocardiography Interventional echocardiography Intracardiac echocardiography Intraoperative echocardiography Prosthetic valves Stress echocardiography Technical innovations Transoesophageal echocardiography Valve disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书