Endotracheal tube size selection in critically ill patients: a 4-year single-center experience in Saudi Arabia.

Annals of Saudi medicine Pub Date : 2026-05-01 Epub Date: 2026-06-05 DOI:10.5144/0256-4947.2026.205
Sara Alquorain, Rabab Hussain Alzanadi, Sundus Almukhodher
{"title":"Endotracheal tube size selection in critically ill patients: a 4-year single-center experience in Saudi Arabia.","authors":"Sara Alquorain, Rabab Hussain Alzanadi, Sundus Almukhodher","doi":"10.5144/0256-4947.2026.205","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Intubation is a critical aspect of airway management and supportive care for intensive care unit (ICU) patients. Inappropriate size of endotracheal tubes (ETT) affects the patient's airway, it is crucial to choose an appropriate size for each patient.</p><p><strong>Objectives: </strong>This study aimed to assess current practices of ETT size.</p><p><strong>Selection: </strong>for adult ICU patients and to explore factors associated with it.</p><p><strong>Design and settings: </strong>Single-center, retrospective cohort study at King Fahad Hospital of the University, Saudi Arabia.</p><p><strong>Patients and methods: </strong>A retrospective review was conducted for adult patients admitted to ICU from January 2020 to January 2024 at King Fahad Hospital of the University. Inclusion criteria included patients aged 18 years or older, underwent intubation and was followed by tracheostomy. Those with missing data, had laryngeal or thyroid masses, had upper airway obstruction by any cause and upper airway surgery were excluded.</p><p><strong>Main outcome and measures: </strong>The primary outcome was compliance of ETT size selection with established guidelines. Secondary outcomes included associations between ETT size (mm), patient demographics and intubation indications.</p><p><strong>Results: </strong>A total of 228 ICU patients were analysed [mean (standard deviation) age of 61.8 (19.6) years]. The median internal diameter of the ETT size was 7.5 mm, with neurological causes being the most common indication for intubation. ETT size showed a significant positive correlation with height (rs=.341; <i>P</i><.001) and weight (rs=0.190; p=0.004), but not with body mass index (rs=.050; <i>P</i>=.456). In multivariable analysis, larger ETT size was significantly associated with male sex (adjusted odds ratio, aOR 2.38, 95% confidence interval, CI 1.12-5.05), pulmonary indication for intubation (aOR 2.31, 95% CI 1.10-4.86), older age (aOR 1.20 per 10 years, 95% CI 1.02-1.42), and height (aOR 1.95 per 10 cm, 95% CI 1.20-3.16), whereas weight was not independently associated after adjustment (aOR 1.04 per 10 kg, 95% CI 0.85-1.26). Overall, 77% of ETT size selection did not comply with height-based guidelines.</p><p><strong>Conclusions: </strong>No standardized ETT size selection guidelines were followed for adult ICU patients. Male sex, height, older age, and pulmonary indication were independent predictors of larger ETT size, supporting the implementation of more structured, height-informed ETT sizing protocols.</p>","PeriodicalId":93875,"journal":{"name":"Annals of Saudi medicine","volume":"46 3","pages":"205-215"},"PeriodicalIF":0.0000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13308743/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Saudi medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5144/0256-4947.2026.205","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/5 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Intubation is a critical aspect of airway management and supportive care for intensive care unit (ICU) patients. Inappropriate size of endotracheal tubes (ETT) affects the patient's airway, it is crucial to choose an appropriate size for each patient.

Objectives: This study aimed to assess current practices of ETT size.

Selection: for adult ICU patients and to explore factors associated with it.

Design and settings: Single-center, retrospective cohort study at King Fahad Hospital of the University, Saudi Arabia.

Patients and methods: A retrospective review was conducted for adult patients admitted to ICU from January 2020 to January 2024 at King Fahad Hospital of the University. Inclusion criteria included patients aged 18 years or older, underwent intubation and was followed by tracheostomy. Those with missing data, had laryngeal or thyroid masses, had upper airway obstruction by any cause and upper airway surgery were excluded.

Main outcome and measures: The primary outcome was compliance of ETT size selection with established guidelines. Secondary outcomes included associations between ETT size (mm), patient demographics and intubation indications.

Results: A total of 228 ICU patients were analysed [mean (standard deviation) age of 61.8 (19.6) years]. The median internal diameter of the ETT size was 7.5 mm, with neurological causes being the most common indication for intubation. ETT size showed a significant positive correlation with height (rs=.341; P<.001) and weight (rs=0.190; p=0.004), but not with body mass index (rs=.050; P=.456). In multivariable analysis, larger ETT size was significantly associated with male sex (adjusted odds ratio, aOR 2.38, 95% confidence interval, CI 1.12-5.05), pulmonary indication for intubation (aOR 2.31, 95% CI 1.10-4.86), older age (aOR 1.20 per 10 years, 95% CI 1.02-1.42), and height (aOR 1.95 per 10 cm, 95% CI 1.20-3.16), whereas weight was not independently associated after adjustment (aOR 1.04 per 10 kg, 95% CI 0.85-1.26). Overall, 77% of ETT size selection did not comply with height-based guidelines.

Conclusions: No standardized ETT size selection guidelines were followed for adult ICU patients. Male sex, height, older age, and pulmonary indication were independent predictors of larger ETT size, supporting the implementation of more structured, height-informed ETT sizing protocols.

危重患者气管插管尺寸选择:沙特阿拉伯4年单中心经验
背景:插管是重症监护病房(ICU)患者气道管理和支持护理的关键方面。气管插管尺寸不合适会影响患者的气道,为每位患者选择合适的气管插管尺寸至关重要。目的:本研究旨在评估ETT大小的现行做法。选择:针对成人ICU患者,探讨与之相关的因素。设计和背景:沙特阿拉伯法赫德国王大学医院的单中心、回顾性队列研究。患者和方法:对2020年1月至2024年1月在法赫德国王医院ICU住院的成年患者进行回顾性分析。纳入标准包括年龄在18岁或以上,接受气管插管和气管切开术的患者。数据缺失、喉部或甲状腺肿物、任何原因引起的上气道阻塞和上气道手术均被排除在外。主要结局和测量:主要结局是ETT大小的选择是否符合既定的指南。次要结局包括气管插管大小(mm)、患者人口统计学和插管指征之间的关系。结果:共分析228例ICU患者[平均(标准差)年龄61.8(19.6)岁]。ETT的中位内径为7.5 mm,神经系统原因是插管最常见的指征。ETT大小与身高呈显著正相关(rs=.341; PP=.456)。在多变量分析中,较大的ETT大小与男性(校正优势比,aOR 2.38, 95%可信区间,CI 1.12-5.05)、肺插管指征(aOR 2.31, 95% CI 1.10-4.86)、年龄(aOR 1.20 / 10年,95% CI 1.02-1.42)和身高(aOR 1.95 / 10厘米,95% CI 1.20-3.16)显著相关,而调整后体重与男性无关(aOR 1.04 / 10公斤,95% CI 0.85-1.26)。总体而言,77%的ETT尺寸选择不符合基于身高的指南。结论:成人ICU患者没有遵循标准化的ETT大小选择指南。男性性别、身高、年龄和肺部指征是较大ETT大小的独立预测因素,支持实施更结构化、身高知情的ETT大小方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书