[Determination of 40 carbonyl compounds in ambient air by high performance liquid chromatography-triple quadrupole mass spectrometry].

Guang-Hui Li, Shuo Deng, Qin-Qin Li, Chun-Lin Zhang, Yun-Feng Liu, Bin Jiang, Qian Yao, Hao Wang, Bo-Guang Wang
{"title":"[Determination of 40 carbonyl compounds in ambient air by high performance liquid chromatography-triple quadrupole mass spectrometry].","authors":"Guang-Hui Li, Shuo Deng, Qin-Qin Li, Chun-Lin Zhang, Yun-Feng Liu, Bin Jiang, Qian Yao, Hao Wang, Bo-Guang Wang","doi":"10.3724/SP.J.1123.2025.04028","DOIUrl":null,"url":null,"abstract":"<p><p>Carbonyl compounds (CCs) are a pivotal class of oxygenated volatile organic compounds in ambient air, which are mainly derived from natural emissions, primary emissions from anthropogenic sources, and secondary formation due to atmospheric oxidation. Various classes of CCs have different impacts on human health, and play critical roles in atmospheric photochemical reactions, ozone production, and the formation of secondary organic aerosols. At present, the number of CCs in ambient air determined by traditional methods is limited, especially for high molecular weight monocarbonyl compounds (HMW-MCs) and dicarbonyl compounds (DCs). If more CCs can be accurately determined, it will be beneficial for the study of atmospheric oxidation mechanisms and the formulation of pollution control strategies.In this study, an analytical method was developed that enables simultaneous determination of the 40 CCs in ambient air with a single injection, utilizing high-performance liquid chromatography-triple quadrupole mass spectrometry. First, the 16 CCs-2,4-dinitrophenylhydrazine (DNPH)-derivatized single standards were prepared using purified DNPH crystals in the laboratory. Second, the remaining 24 commercial CCs-DNPH-derivatized hybrid standards were purchased. Finally, all the above standards were mixed in a certain proportion to prepare the 40 CCs-DNPH-derivatized hybrid standards for later use. The sample collection procedures (sampling flow rate and sampling duration), the pretreatment methods (elution volume and constant volume), the chromatographic analysis conditions (chromatographic column, the concentration of ammonium acetate, etc.) and the mass spectrometry analysis conditions (ion source parameters, fragmentation voltage, collision energy, etc.) were optimized. Ambient air samples were collected using DNPH cartridges (at a flow rate of 1 L/min, for 4 h), eluted with 4 mL of acetonitrile and diluted to a final volume of 5 mL (the acetonitrile naturally flowed through the DNPH cartridges in the opposite direction to the sampling direction) in a vacuum drying chamber, and then filtered through a 0.22 μm organic filter membrane and transferred to 1.5 mL brown sample bottles prior to instrumental analysis. Chromatographic separation was performed using a Sepax BR-C18 column (250 mm×4.6 mm, 5 μm) with mobile phases consisting of 1.0 mmol/L ammonium aqueous solution and acetonitrile under gradient elution conditions. The analysis was performed at a column temperature of 50 ℃ with an injection volume of 5 μL. The target analytes were identified using negative electrospray ionization (ESI<sup>-</sup>) and multiple reaction monitoring (MRM) modes and quantified using the external standard method. The results showed that the 40 CCs exhibited good linearities within the mass concentration range of 2.5-200 μg/L, with the determination coefficients (<i>R</i><sup>2</sup>) exceeding 0.997 8. The method detection limits and method quantification limits were established within the ranges of 0.001-0.03 μg/m<sup>3</sup> and 0.005-0.12 μg/m<sup>3</sup>, respectively. The blank spiked recoveries of the target analytes at low, middle, and high concentration levels (0.05, 0.1, and 0.2 μg) ranged from 75.2% to 119.0%, while the relative standard deviations (RSDs, <i>n</i>=7) ranged from 0.4% to 4.2%. This analytical method was applied to the monitoring of ambient samples in the Pearl River Delta region. Except for 2-furaldehyde and isophorone, 38 CCs were effectively detected. Among these, formaldehyde, acetaldehyde and nonanal consistently showed higher concentrations across all sampling sites. Overall, the concentrations of low molecular weight monocarbonyl compounds (LMW-MCs) were moderately higher than those of HMW-MCs, and substantially higher than those of DCs. Compared with conventional methods, this method effectively overcame the limitations in existing approaches regarding the limited variety and detection difficulties of DCs and HMW-MCs. Additionally, it also improved the chromatographic resolution of target analytes which have similar retention times and the same ion pairs. Overall, this method was simple and rapid, offering excellent sensitivity, precision, and chromatographic resolution. It was suitable for the determination of the abovementioned 40 CCs in ambient air..</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"44 6","pages":"694-704"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13237626/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2025.04028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Carbonyl compounds (CCs) are a pivotal class of oxygenated volatile organic compounds in ambient air, which are mainly derived from natural emissions, primary emissions from anthropogenic sources, and secondary formation due to atmospheric oxidation. Various classes of CCs have different impacts on human health, and play critical roles in atmospheric photochemical reactions, ozone production, and the formation of secondary organic aerosols. At present, the number of CCs in ambient air determined by traditional methods is limited, especially for high molecular weight monocarbonyl compounds (HMW-MCs) and dicarbonyl compounds (DCs). If more CCs can be accurately determined, it will be beneficial for the study of atmospheric oxidation mechanisms and the formulation of pollution control strategies.In this study, an analytical method was developed that enables simultaneous determination of the 40 CCs in ambient air with a single injection, utilizing high-performance liquid chromatography-triple quadrupole mass spectrometry. First, the 16 CCs-2,4-dinitrophenylhydrazine (DNPH)-derivatized single standards were prepared using purified DNPH crystals in the laboratory. Second, the remaining 24 commercial CCs-DNPH-derivatized hybrid standards were purchased. Finally, all the above standards were mixed in a certain proportion to prepare the 40 CCs-DNPH-derivatized hybrid standards for later use. The sample collection procedures (sampling flow rate and sampling duration), the pretreatment methods (elution volume and constant volume), the chromatographic analysis conditions (chromatographic column, the concentration of ammonium acetate, etc.) and the mass spectrometry analysis conditions (ion source parameters, fragmentation voltage, collision energy, etc.) were optimized. Ambient air samples were collected using DNPH cartridges (at a flow rate of 1 L/min, for 4 h), eluted with 4 mL of acetonitrile and diluted to a final volume of 5 mL (the acetonitrile naturally flowed through the DNPH cartridges in the opposite direction to the sampling direction) in a vacuum drying chamber, and then filtered through a 0.22 μm organic filter membrane and transferred to 1.5 mL brown sample bottles prior to instrumental analysis. Chromatographic separation was performed using a Sepax BR-C18 column (250 mm×4.6 mm, 5 μm) with mobile phases consisting of 1.0 mmol/L ammonium aqueous solution and acetonitrile under gradient elution conditions. The analysis was performed at a column temperature of 50 ℃ with an injection volume of 5 μL. The target analytes were identified using negative electrospray ionization (ESI-) and multiple reaction monitoring (MRM) modes and quantified using the external standard method. The results showed that the 40 CCs exhibited good linearities within the mass concentration range of 2.5-200 μg/L, with the determination coefficients (R2) exceeding 0.997 8. The method detection limits and method quantification limits were established within the ranges of 0.001-0.03 μg/m3 and 0.005-0.12 μg/m3, respectively. The blank spiked recoveries of the target analytes at low, middle, and high concentration levels (0.05, 0.1, and 0.2 μg) ranged from 75.2% to 119.0%, while the relative standard deviations (RSDs, n=7) ranged from 0.4% to 4.2%. This analytical method was applied to the monitoring of ambient samples in the Pearl River Delta region. Except for 2-furaldehyde and isophorone, 38 CCs were effectively detected. Among these, formaldehyde, acetaldehyde and nonanal consistently showed higher concentrations across all sampling sites. Overall, the concentrations of low molecular weight monocarbonyl compounds (LMW-MCs) were moderately higher than those of HMW-MCs, and substantially higher than those of DCs. Compared with conventional methods, this method effectively overcame the limitations in existing approaches regarding the limited variety and detection difficulties of DCs and HMW-MCs. Additionally, it also improved the chromatographic resolution of target analytes which have similar retention times and the same ion pairs. Overall, this method was simple and rapid, offering excellent sensitivity, precision, and chromatographic resolution. It was suitable for the determination of the abovementioned 40 CCs in ambient air..

高效液相色谱-三重四极杆质谱法测定环境空气中40种羰基化合物
羰基化合物(CCs)是环境空气中一类重要的含氧挥发性有机化合物,主要来源于自然排放、人为源的一次排放和大气氧化的二次形成。各类CCs对人类健康有不同的影响,并在大气光化学反应、臭氧产生和二次有机气溶胶的形成中发挥关键作用。目前,用传统方法测定环境空气中CCs的数量有限,特别是对于高分子量的单羰基化合物(HMW-MCs)和二羰基化合物(DCs)。如果能够准确测定更多的碳捕获量,将有利于研究大气氧化机理和制定污染控制策略。在本研究中,开发了一种分析方法,利用高效液相色谱-三重四极杆质谱法,一次注射即可同时测定环境空气中的40cc。首先,在实验室用纯化的DNPH晶体制备了16个ccs -2,4-二硝基苯肼(DNPH)衍生的单一标准品。其次,购买了剩余的24个商用cc - dnph衍生混合标准。最后将以上标准品按一定比例混合,制得40份cc - dnph衍生混合标准品备用。优化了样品采集流程(采样流速和采样时间)、预处理方法(洗脱体积和定容)、色谱分析条件(色谱柱、乙酸铵浓度等)和质谱分析条件(离子源参数、破碎电压、碰撞能量等)。环境空气样品用DNPH瓶(流速为1 L/min,持续4 h)收集,用4 mL乙腈洗脱,并在真空干燥室中稀释至终体积5 mL(乙腈自然沿与取样方向相反的方向流过DNPH瓶),然后通过0.22 μm有机过滤膜过滤,转移到1.5 mL棕色样品瓶中进行仪器分析。色谱柱为Sepax BR-C18 (250 mm×4.6 mm, 5 μm),流动相为1.0 mmol/L铵水溶液和乙腈,梯度洗脱。柱温为50℃,进样量为5 μL。采用负电喷雾电离(ESI-)和多重反应监测(MRM)模式对目标分析物进行鉴定,并采用外标法进行定量。结果表明,40种cc在2.5 ~ 200 μg/L的质量浓度范围内线性良好,测定系数(R2)均大于0.997 8。建立的方法检出限和定量限分别在0.001 ~ 0.03 μg/m3和0.005 ~ 0.12 μg/m3范围内。目标分析物在低、中、高浓度水平(0.05、0.1、0.2 μg)下的空白加标回收率为75.2% ~ 119.0%,相对标准偏差(rsd, n=7)为0.4% ~ 4.2%。将该分析方法应用于珠江三角洲地区环境样品的监测。除2-呋喃醛和异佛酮外,有效检出38种CCs。其中,甲醛、乙醛和壬醛在所有采样点的浓度一致较高。总体而言,低分子量单羰基化合物(LMW-MCs)的浓度略高于HMW-MCs,显著高于DCs。与传统方法相比,该方法有效克服了现有方法中dc和hmw - mc种类有限和检测困难的局限性。此外,它还提高了具有相似保留时间和相同离子对的目标分析物的色谱分辨率。该方法简便、快速,具有良好的灵敏度、精密度和色谱分辨率。适用于环境空气中上述40cc的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书