[Determination of 16 organic ultraviolet absorbers in drinking water by solid phase extraction-ultra-high performance liquid chromatography-tandem mass spectrometry].

Zhuo Wang, Can Zhao, Bi-Xiong Ye, Yong-Yan Chen
{"title":"[Determination of 16 organic ultraviolet absorbers in drinking water by solid phase extraction-ultra-high performance liquid chromatography-tandem mass spectrometry].","authors":"Zhuo Wang, Can Zhao, Bi-Xiong Ye, Yong-Yan Chen","doi":"10.3724/SP.J.1123.2025.10015","DOIUrl":null,"url":null,"abstract":"<p><p>Organic ultraviolet absorbers (OUVAs) are a class of emerging contaminants that have garnered significant attention in recent years. In response to the characteristics of high detection frequency and low concentrations of OUVAs in water bodies, this study established an analytical method based on solid phase extraction (SPE) coupled with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) for the simultaneous determination of 16 OUVAs (nine UV stabilizers and seven UV filters) in drinking water. The 500 mL water sample was pretreated with 25 mg ascorbic acid, acidified to pH 2-3, and spiked with 1 mL of 5 μg/L mixed internal standard working solution. Target compounds were enriched and concentrated using an HLB solid phase extraction cartridge (200 mg/6 mL). Separation was achieved on an Acquity Premier BEH C<sub>18</sub> column (100 mm×2.1 mm, 1.7 μm) using a gradient elution with methanol and 2 mmol/L ammonium acetate aqueous solution as the mobile phases. Detection was performed using electrospray ionization in positive mode and multiple reaction monitoring (MRM), with quantification carried out by the internal standard method. The precision and accuracy of the established method were evaluated using drinking water as the matrix. The results showed that all 16 OUVAs exhibited good linearity within their respective mass concentration ranges, with correlation coefficients (<i>r</i>) greater than 0.992. The method detection limits (MDL, <i>S/N=</i>3) were 0.03-5 ng/L, and the method quantification limits (MQL, <i>S/N=</i>10) were 0.1-15 ng/L. At spiked levels of 5, 20 and 50 ng/L, the recoveries of the target analytes ranged from 75.0% to 130.6%, with relative standard deviations (RSDs) ranging from 0.9% to 12.9% (<i>n</i>=6). A total of seven source water samples and seven drinking water samples were analyzed using this method. The results showed that two OUVAs, 2-hydroxy-4-methoxybenzophenone (UV-9) and octocrylene (OC) were detected. In source water, the mass concentrations of UV-9 ranged from <MQL to 13.4 ng/L, while OC mass concentrations ranged from 5.0 to 32.23 ng/L. In drinking water, UV-9 was detected at 0.4 ng/L, and OC mass concentrations ranged from <MQL to 13.2 ng/L. This method is suitable for the trace analysis of 16 OUVAs in drinking water, demonstrating good accuracy and precision. It effectively improves the detection efficiency of OUVAs in water and can be used for the environmental monitoring and analysis of OUVAs in drinking water in China.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"44 6","pages":"650-657"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13237622/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2025.10015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Organic ultraviolet absorbers (OUVAs) are a class of emerging contaminants that have garnered significant attention in recent years. In response to the characteristics of high detection frequency and low concentrations of OUVAs in water bodies, this study established an analytical method based on solid phase extraction (SPE) coupled with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) for the simultaneous determination of 16 OUVAs (nine UV stabilizers and seven UV filters) in drinking water. The 500 mL water sample was pretreated with 25 mg ascorbic acid, acidified to pH 2-3, and spiked with 1 mL of 5 μg/L mixed internal standard working solution. Target compounds were enriched and concentrated using an HLB solid phase extraction cartridge (200 mg/6 mL). Separation was achieved on an Acquity Premier BEH C18 column (100 mm×2.1 mm, 1.7 μm) using a gradient elution with methanol and 2 mmol/L ammonium acetate aqueous solution as the mobile phases. Detection was performed using electrospray ionization in positive mode and multiple reaction monitoring (MRM), with quantification carried out by the internal standard method. The precision and accuracy of the established method were evaluated using drinking water as the matrix. The results showed that all 16 OUVAs exhibited good linearity within their respective mass concentration ranges, with correlation coefficients (r) greater than 0.992. The method detection limits (MDL, S/N=3) were 0.03-5 ng/L, and the method quantification limits (MQL, S/N=10) were 0.1-15 ng/L. At spiked levels of 5, 20 and 50 ng/L, the recoveries of the target analytes ranged from 75.0% to 130.6%, with relative standard deviations (RSDs) ranging from 0.9% to 12.9% (n=6). A total of seven source water samples and seven drinking water samples were analyzed using this method. The results showed that two OUVAs, 2-hydroxy-4-methoxybenzophenone (UV-9) and octocrylene (OC) were detected. In source water, the mass concentrations of UV-9 ranged from

[固相萃取-高效液相色谱-串联质谱法测定饮用水中16种有机紫外吸收剂]。
有机紫外线吸收剂(ouva)是近年来引起人们极大关注的一类新兴污染物。针对水体中ouva检测频率高、浓度低的特点,本研究建立了固相萃取(SPE) -超高效液相色谱-串联质谱(UHPLC-MS/MS)同时测定饮用水中16种ouva(9种UV稳定剂和7种UV过滤剂)的分析方法。500ml水样用25mg抗坏血酸预处理,酸化至pH 2 ~ 3,加入5 μg/L混合内标工作液1ml。用HLB固相萃取筒(200 mg/6 mL)富集和浓缩目标化合物。采用Acquity Premier BEH C18色谱柱(100 mm×2.1 mm, 1.7 μm),以甲醇和2 mmol/L乙酸铵水溶液为流动相进行梯度洗脱。采用正模式电喷雾电离和多重反应监测(MRM)进行检测,内标法进行定量。以饮用水为基质,评价了该方法的精密度和准确度。结果表明,16种OUVAs在各自的质量浓度范围内均具有良好的线性关系,相关系数(r)均大于0.992。方法检出限(MDL, S/N=3)为0.03 ~ 5 ng/L,定量限(MQL, S/N=10)为0.1 ~ 15 ng/L。在加标水平为5、20和50 ng/L时,目标分析物的加标回收率为75.0% ~ 130.6%,相对标准偏差(rsd)为0.9% ~ 12.9% (n=6)。采用该方法对7个水源水样和7个饮用水水样进行了分析。结果表明,检测到2-羟基-4-甲氧基二苯甲酮(UV-9)和八烯(OC)两种ouva。在水源中,UV-9的质量浓度从
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书