[Determination of 13 prohibited alkaloids in essential oil-based cosmetics by ultra performance liquid chromatography-tandem mass spectrometry combining QuEChERS purification].

Zhen Liu, Yu-Mei Wang, Jian-Bin Pan, Ling-Li Zong, Yu-Han Song, Xiao-Jie Sun, Hong-Yuan Chen
{"title":"[Determination of 13 prohibited alkaloids in essential oil-based cosmetics by ultra performance liquid chromatography-tandem mass spectrometry combining QuEChERS purification].","authors":"Zhen Liu, Yu-Mei Wang, Jian-Bin Pan, Ling-Li Zong, Yu-Han Song, Xiao-Jie Sun, Hong-Yuan Chen","doi":"10.3724/SP.J.1123.2025.10009","DOIUrl":null,"url":null,"abstract":"<p><p>Alkaloids represent a class of naturally-occurring nitrogen-containing compounds widely distributed across diverse plant species. Owing to their well-documented potential to induce adverse effects on human health, certain alkaloids are explicitly prohibited from being used in cosmetic formulations. The escalating global popularity of essential oil-based cosmetics, which commonly incorporate complex botanical extracts, presents a potential avenue for the inadvertent introduction of these prohibited substances. Consequently, the development of robust, sensitive, and efficient analytical methods for their monitoring is of utmost significance for consumer safety and regulatory compliance. This study devises a reliable, high-throughput approach for the simultaneous determination of 13 prohibited alkaloids in essential oil-based cosmetics. It integrates optimized QuEChERS sample preparation with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The sample preparation procedure was meticulously designed to maximize efficiency and minimize analyte loss. Chromatographic separation was accomplished on a Waters ACQUITY UPLC HSS T3 column (100 mm × 2.1 mm, 1.8 μm) maintained at a constant temperature of 30 ℃. The mobile phase was composed of (A) acetonitrile and (B) 0.1% (volume fraction) formic acid aqueous solution. A gradient elution program was implemented at a stable flow rate of 0.3 mL/min according to the following profile: an initial 5, a linear increase to 15 (0-2 min), a rapid rise to 70 (2-4.5 min), followed by an immediate reversion to the initial 5 (4.5-5.5 min), which was maintained for re-equilibration until 7.0 min. The injection volume was 5 µL. Detection and quantification were conducted using a triple quadrupole mass spectrometer equipped with an electrospray ionization (ESI) source operating in positive ion mode (ESI<sup>+</sup>). Data acquisition was carried out in the multiple reaction monitoring (MRM) mode to ensure superior specificity and sensitivity. For each of the 13 alkaloids, two specific ion transitions were monitored: one for quantitative analysis and the other for confirmatory identification. The method was rigorously validated in accordance with accepted analytical guidelines. All 13 target alkaloids displayed excellent linearity within a mass concentration range of 0.2 to 50 ng/mL, with correlation coefficients (<i>R</i><sup>2</sup>) consistently exceeding 0.99. The limits of detection (LODs) and limits of quantification (LOQs), determined with acceptable accuracy and precision, ranged from 1 µg/kg to 4 µg/kg and 2 µg/kg to 10 µg/kg, respectively. Method accuracy and precision were assessed through recovery tests at three spiking levels, with six replicates at each level. The mean recoveries for all analytes ranged from 83.9% to 119.1%, with associated relative standard deviations (RSDs) all being ≤7.3%, validating the method's high reliability and repeatability. Systematic evaluation indicated that the matrix effects for the 13 analytes were negligible; hence, the solvent calibration curve was adopted for quantitative analysis. The practical applicability of the validated method was demonstrated through the analysis of 50 batches of commercially available essential oil-based cosmetics. This market survey encompassed 15 products specifically marketed for infants or children and 35 products intended for adult use. As a result, none of the 13 target prohibited alkaloids were detected in any of the tested samples above their respective LOQs. A particularly notable accomplishment of this work is the successful development of a sensitive and reliable quantification strategy for oleandrin, a potent cardiotoxic alkaloid for which standardized detection methods in complex cosmetic matrices such as essential oils have been conspicuously absent. In conclusion, this study successfully establishes a simple, rapid, sensitive, and robust QuEChERS-UPLC-MS/MS method. It is comprehensively validated and clearly well-suited for the routine screening, risk monitoring, and quality control of 13 prohibited alkaloids in a wide array of essential oil-based cosmetics. The method offers reliable technical support for regulatory bodies to enforce safety standards and for manufacturers to ensure the safety and compliance of their products, thereby effectively contributing to the protection of consumer health.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"44 6","pages":"667-674"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13237628/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2025.10009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Alkaloids represent a class of naturally-occurring nitrogen-containing compounds widely distributed across diverse plant species. Owing to their well-documented potential to induce adverse effects on human health, certain alkaloids are explicitly prohibited from being used in cosmetic formulations. The escalating global popularity of essential oil-based cosmetics, which commonly incorporate complex botanical extracts, presents a potential avenue for the inadvertent introduction of these prohibited substances. Consequently, the development of robust, sensitive, and efficient analytical methods for their monitoring is of utmost significance for consumer safety and regulatory compliance. This study devises a reliable, high-throughput approach for the simultaneous determination of 13 prohibited alkaloids in essential oil-based cosmetics. It integrates optimized QuEChERS sample preparation with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The sample preparation procedure was meticulously designed to maximize efficiency and minimize analyte loss. Chromatographic separation was accomplished on a Waters ACQUITY UPLC HSS T3 column (100 mm × 2.1 mm, 1.8 μm) maintained at a constant temperature of 30 ℃. The mobile phase was composed of (A) acetonitrile and (B) 0.1% (volume fraction) formic acid aqueous solution. A gradient elution program was implemented at a stable flow rate of 0.3 mL/min according to the following profile: an initial 5, a linear increase to 15 (0-2 min), a rapid rise to 70 (2-4.5 min), followed by an immediate reversion to the initial 5 (4.5-5.5 min), which was maintained for re-equilibration until 7.0 min. The injection volume was 5 µL. Detection and quantification were conducted using a triple quadrupole mass spectrometer equipped with an electrospray ionization (ESI) source operating in positive ion mode (ESI+). Data acquisition was carried out in the multiple reaction monitoring (MRM) mode to ensure superior specificity and sensitivity. For each of the 13 alkaloids, two specific ion transitions were monitored: one for quantitative analysis and the other for confirmatory identification. The method was rigorously validated in accordance with accepted analytical guidelines. All 13 target alkaloids displayed excellent linearity within a mass concentration range of 0.2 to 50 ng/mL, with correlation coefficients (R2) consistently exceeding 0.99. The limits of detection (LODs) and limits of quantification (LOQs), determined with acceptable accuracy and precision, ranged from 1 µg/kg to 4 µg/kg and 2 µg/kg to 10 µg/kg, respectively. Method accuracy and precision were assessed through recovery tests at three spiking levels, with six replicates at each level. The mean recoveries for all analytes ranged from 83.9% to 119.1%, with associated relative standard deviations (RSDs) all being ≤7.3%, validating the method's high reliability and repeatability. Systematic evaluation indicated that the matrix effects for the 13 analytes were negligible; hence, the solvent calibration curve was adopted for quantitative analysis. The practical applicability of the validated method was demonstrated through the analysis of 50 batches of commercially available essential oil-based cosmetics. This market survey encompassed 15 products specifically marketed for infants or children and 35 products intended for adult use. As a result, none of the 13 target prohibited alkaloids were detected in any of the tested samples above their respective LOQs. A particularly notable accomplishment of this work is the successful development of a sensitive and reliable quantification strategy for oleandrin, a potent cardiotoxic alkaloid for which standardized detection methods in complex cosmetic matrices such as essential oils have been conspicuously absent. In conclusion, this study successfully establishes a simple, rapid, sensitive, and robust QuEChERS-UPLC-MS/MS method. It is comprehensively validated and clearly well-suited for the routine screening, risk monitoring, and quality control of 13 prohibited alkaloids in a wide array of essential oil-based cosmetics. The method offers reliable technical support for regulatory bodies to enforce safety standards and for manufacturers to ensure the safety and compliance of their products, thereby effectively contributing to the protection of consumer health.

[超高效液相色谱-串联质谱联合QuEChERS纯化法测定精油类化妆品中13种禁用生物碱]。
生物碱是一类天然存在的含氮化合物,广泛分布于多种植物物种中。由于有充分证据表明,某些生物碱可能对人体健康产生不利影响,因此明确禁止在化妆品配方中使用。精油类化妆品通常含有复杂的植物提取物,在全球越来越受欢迎,这为无意中引入这些违禁物质提供了潜在的途径。因此,开发稳健、灵敏和有效的分析方法来监测它们对消费者安全和法规遵从性至关重要。本研究设计了一种可靠、高通量的同时测定精油类化妆品中13种禁用生物碱的方法。它集成了优化的QuEChERS样品制备与超高效液相色谱-串联质谱(UPLC-MS/MS)。样品制备过程精心设计,以最大限度地提高效率和减少分析物损失。色谱分离采用Waters ACQUITY UPLC HSS T3色谱柱(100 mm × 2.1 mm, 1.8 μm),温度为30℃。流动相为(A)乙腈和(B) 0.1%(体积分数)甲酸水溶液。以0.3 mL/min的稳定流速进行梯度洗脱程序,根据以下情况进行:初始5,线性增加到15(0-2分钟),快速上升到70(2-4.5分钟),然后立即恢复到初始5(4.5-5.5分钟),保持重新平衡直到7.0分钟。进样量为5µL。检测和定量使用配备电喷雾离子源(ESI+)的三重四极杆质谱仪进行。数据采集采用多反应监测(MRM)模式,以确保较高的特异性和敏感性。对于13种生物碱中的每一种,监测了两个特定的离子转变:一个用于定量分析,另一个用于验证性鉴定。该方法按照公认的分析准则进行了严格的验证。13种目标生物碱在0.2 ~ 50 ng/mL的质量浓度范围内呈良好的线性关系,相关系数(R2)均大于0.99。以可接受的准确度和精密度确定的检出限(lod)和定量限(loq)范围分别为1µg/kg至4µg/kg和2µg/kg至10µg/kg。方法的准确度和精密度通过3个尖峰水平的回收率试验进行评估,每个水平6个重复。平均加样回收率为83.9% ~ 119.1%,相关相对标准偏差(rsd)均≤7.3%,验证了方法的高可靠性和重复性。系统评价表明,13种分析物的基质效应可以忽略不计,因此采用溶剂校准曲线进行定量分析。通过对50批市售精油类化妆品的分析,验证了该方法的实用性。这项市场调查包括15种专门为婴儿或儿童销售的产品和35种供成人使用的产品。结果,13种目标禁用生物碱在任何测试样本中均未检出超过其各自的定量限。这项工作的一个特别值得注意的成就是成功地开发了一种敏感可靠的夹竹桃素定量策略,夹竹桃素是一种有效的心脏毒性生物碱,在复杂的化妆品基质(如精油)中明显缺乏标准化检测方法。总之,本研究成功建立了一种简便、快速、灵敏、鲁棒的QuEChERS-UPLC-MS/MS方法。它经过全面验证,显然非常适合于各种精油化妆品中13种禁用生物碱的常规筛选、风险监测和质量控制。该方法为监管机构执行安全标准和制造商确保其产品的安全性和合规性提供可靠的技术支持,从而有效地促进保护消费者健康。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书