{"title":"Study of secondary neutron and γ dose distribution based on a TLD array and 3D-printed tissue-equivalent phantom.","authors":"Shuquan Wei, Zishen Wang, Yidi Wang, Gaolong Zhang, Shouping Xu, Wei Cheng, Zhen Huang, Xiaoyu Xu, Weiwei Qu","doi":"10.1016/j.meddos.2026.05.002","DOIUrl":null,"url":null,"abstract":"<p><p>Secondary neutron and gamma radiation in proton therapy raise concerns regarding out-of-field doses and heightened risks of secondary malignancies, particularly in pediatric cases. This study aims to develop and validate a novel 3-dimensional (3D) printed, tissue-equivalent phantom designed to enhance the precision of absorbed dose measurements and improve treatment planning in proton therapy. The phantom was fabricated using advanced 3D printing technology to mimic the radiological properties of human tissues, including electron density and proton stopping power. Thermoluminescent detectors (TLDs) were embedded at designated locations to measure doses resulting from proton irradiation. The γ-ray dose distribution inside the phantom was verified by comparison with Monte Carlo simulations using the GATE toolkit to ensure consistency and reliability. Measured dose distributions demonstrated strong consistency with simulations. Within the treatment field, the dose distribution exhibited high precision, while secondary doses featured a sharp decline beyond 6 cm from the target center. Doses fell below 5 mSv/Gy(RBE) within 1 cm of the boundary and continued to taper off to 0.05∼0.15 mSv/Gy(RBE) further away. Neutron dose equivalents were recorded at less than 1.5 mSv/Gy(RBE) between 5∼10 cm, declining below 1.0 mSv/Gy(RBE) beyond 10 cm. The 3D-printed phantom demonstrated high reliability and accuracy in dosimetry. It represents a robust tool for quality assurance in proton therapy planning and for evaluating patient-specific out-of-field doses. The model is expected to improve the safety and efficacy of radiation therapy, addressing critical concerns relevant to vulnerable populations. Furthermore, the measured out-of-field neutron doses were compared with the results from published studies to verify the rationality of the experimental data, which could provide a reference for the secondary neutron risk assessment of low-energy proton radiotherapy.</p>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.meddos.2026.05.002","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Secondary neutron and gamma radiation in proton therapy raise concerns regarding out-of-field doses and heightened risks of secondary malignancies, particularly in pediatric cases. This study aims to develop and validate a novel 3-dimensional (3D) printed, tissue-equivalent phantom designed to enhance the precision of absorbed dose measurements and improve treatment planning in proton therapy. The phantom was fabricated using advanced 3D printing technology to mimic the radiological properties of human tissues, including electron density and proton stopping power. Thermoluminescent detectors (TLDs) were embedded at designated locations to measure doses resulting from proton irradiation. The γ-ray dose distribution inside the phantom was verified by comparison with Monte Carlo simulations using the GATE toolkit to ensure consistency and reliability. Measured dose distributions demonstrated strong consistency with simulations. Within the treatment field, the dose distribution exhibited high precision, while secondary doses featured a sharp decline beyond 6 cm from the target center. Doses fell below 5 mSv/Gy(RBE) within 1 cm of the boundary and continued to taper off to 0.05∼0.15 mSv/Gy(RBE) further away. Neutron dose equivalents were recorded at less than 1.5 mSv/Gy(RBE) between 5∼10 cm, declining below 1.0 mSv/Gy(RBE) beyond 10 cm. The 3D-printed phantom demonstrated high reliability and accuracy in dosimetry. It represents a robust tool for quality assurance in proton therapy planning and for evaluating patient-specific out-of-field doses. The model is expected to improve the safety and efficacy of radiation therapy, addressing critical concerns relevant to vulnerable populations. Furthermore, the measured out-of-field neutron doses were compared with the results from published studies to verify the rationality of the experimental data, which could provide a reference for the secondary neutron risk assessment of low-energy proton radiotherapy.

基于TLD阵列和3d打印组织等效模型的二次中子和γ剂量分布研究。
质子治疗中的二次中子和伽马辐射引起了对场外剂量的关注,并增加了继发性恶性肿瘤的风险,特别是在儿科病例中。本研究旨在开发和验证一种新的三维(3D)打印,组织等效的幻影,旨在提高吸收剂量测量的精度,并改善质子治疗的治疗计划。该模型采用先进的3D打印技术制造,模拟人体组织的放射学特性,包括电子密度和质子停止能力。在指定位置嵌入热释光探测器(TLDs)以测量质子辐照产生的剂量。利用GATE工具包与蒙特卡罗模拟进行对比,验证了模体内γ射线剂量分布,以确保一致性和可靠性。测量到的剂量分布与模拟结果具有很强的一致性。在治疗场内,剂量分布具有较高的精度,而二次剂量在距靶中心6cm处急剧下降。剂量在距边界1厘米范围内降至5毫西弗/戈瑞(RBE)以下,并继续逐渐减少至0.05 ~ 0.15毫西弗/戈瑞(RBE)。在5 ~ 10 cm之间记录的中子剂量当量小于1.5 mSv/Gy(RBE),在10 cm以上下降到1.0 mSv/Gy(RBE)以下。3d打印的模型在剂量测定中具有较高的可靠性和准确性。它代表了质子治疗计划质量保证和评估患者特异性场外剂量的强大工具。该模型有望提高放射治疗的安全性和有效性,解决与弱势群体相关的关键问题。并将实测的场外中子剂量与已发表的研究结果进行对比,验证实验数据的合理性,为低能质子放疗的二次中子风险评估提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Dosimetry
Medical Dosimetry 医学-核医学
CiteScore
2.40
自引率
0.00%
发文量
51
审稿时长
34 days
期刊介绍: Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书