Quantifying the Impact of Discrepancies Between Actual and Recorded Blood Sampling Times on Bayesian Forecasting for Area Under the Concentration–Time Curve Estimation of Vancomycin
{"title":"Quantifying the Impact of Discrepancies Between Actual and Recorded Blood Sampling Times on Bayesian Forecasting for Area Under the Concentration–Time Curve Estimation of Vancomycin","authors":"Tomoyuki Yamada, Kazutaka Oda, Yoko Hiyama, Takashi Ueda, Hirokazu Furusho, Tomomi Katanoda, Takashi Tomita, Hiroaki Matsuo, Takeshi Ide, Sachiko Jingami, Yusuke Kusaka, Hirofumi Jono","doi":"10.1111/bcpt.70254","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The effect of discrepancies in sampling time on the accuracy of area under the concentration–time curve (AUC) estimation remains unclear. We evaluated how discrepancies between actual and recorded blood sampling times impact vancomycin AUC estimation using one-point (trough) and two-point (trough and peak) strategies in critically ill patients. In total, 25 patients at five Japanese hospitals were enrolled; 21 underwent sampling on Day 1 (AUC<sub>day1</sub>) and 14 on Days 3–5 (AUC<sub>ss</sub>). Reference AUCs were calculated using trapezoidal methods. Bayesian forecasting estimated AUCs from one- or two-point sampling. Systematic trough (≤ 4 h earlier) and peak (−1 to +4 h) time discrepancies were introduced. Predictive performance was defined as estimated/reference AUC ratios within an acceptable range of 0.9–1.1. For AUC<sub>day1</sub>, two-point sampling was more robust to trough discrepancies than one-point sampling (acceptable interquartile range [IQR] up to 105 vs. 30 min) but highly sensitive to peak timing (acceptable IQR −20 and +10 min). For AUC<sub>ss</sub>, similar trends were observed. Overall, two-point sampling offers superior robustness against trough discrepancies. However, because peak sampling is highly sensitive to timing errors, if the exact peak sampling time cannot be verified, clinicians may consider remeasuring the concentration or switching to one-point trough sampling.</p>\n </div>","PeriodicalId":8733,"journal":{"name":"Basic & Clinical Pharmacology & Toxicology","volume":"139 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Basic & Clinical Pharmacology & Toxicology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/bcpt.70254","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
The effect of discrepancies in sampling time on the accuracy of area under the concentration–time curve (AUC) estimation remains unclear. We evaluated how discrepancies between actual and recorded blood sampling times impact vancomycin AUC estimation using one-point (trough) and two-point (trough and peak) strategies in critically ill patients. In total, 25 patients at five Japanese hospitals were enrolled; 21 underwent sampling on Day 1 (AUCday1) and 14 on Days 3–5 (AUCss). Reference AUCs were calculated using trapezoidal methods. Bayesian forecasting estimated AUCs from one- or two-point sampling. Systematic trough (≤ 4 h earlier) and peak (−1 to +4 h) time discrepancies were introduced. Predictive performance was defined as estimated/reference AUC ratios within an acceptable range of 0.9–1.1. For AUCday1, two-point sampling was more robust to trough discrepancies than one-point sampling (acceptable interquartile range [IQR] up to 105 vs. 30 min) but highly sensitive to peak timing (acceptable IQR −20 and +10 min). For AUCss, similar trends were observed. Overall, two-point sampling offers superior robustness against trough discrepancies. However, because peak sampling is highly sensitive to timing errors, if the exact peak sampling time cannot be verified, clinicians may consider remeasuring the concentration or switching to one-point trough sampling.
采样时间的差异对浓度-时间曲线下面积(AUC)估计精度的影响尚不清楚。我们评估了实际和记录的血液采样时间之间的差异如何影响危重患者使用一点(波谷)和两点(波谷和波峰)策略估计万古霉素AUC。总共有来自日本5家医院的25名患者被纳入研究;21例在第1天(AUCday1)取样,14例在第3-5天(AUCss)取样。参考auc采用梯形法计算。贝叶斯预测从一点或两点抽样估计auc。引入了系统波谷(≤4 h)和波峰(-1至+4 h)时间差异。预测性能定义为在0.9-1.1可接受范围内的估计/参考AUC比率。对于AUCday1,两点采样比一点采样对波谷差异更稳健(可接受的四分位数范围[IQR]高达105 vs 30分钟),但对峰值时间(可接受的IQR为-20和+10分钟)高度敏感。对于aucs,也观察到类似的趋势。总的来说,两点抽样对波谷差异提供了优越的稳健性。然而,由于峰值采样对时间误差高度敏感,如果无法验证准确的峰值采样时间,临床医生可能会考虑重新测量浓度或切换到一点波谷采样。
期刊介绍:
Basic & Clinical Pharmacology and Toxicology is an independent journal, publishing original scientific research in all fields of toxicology, basic and clinical pharmacology. This includes experimental animal pharmacology and toxicology and molecular (-genetic), biochemical and cellular pharmacology and toxicology. It also includes all aspects of clinical pharmacology: pharmacokinetics, pharmacodynamics, therapeutic drug monitoring, drug/drug interactions, pharmacogenetics/-genomics, pharmacoepidemiology, pharmacovigilance, pharmacoeconomics, randomized controlled clinical trials and rational pharmacotherapy. For all compounds used in the studies, the chemical constitution and composition should be known, also for natural compounds.