Abdulkadir Muhammed Bulut, Sancar Bakircioglu, Elif Naz Perdeci, Teyfik Demir, Fatma Kubra Erbay Elibol, Güney Yilmaz
{"title":"Biomechanical effects of medial comminution and K-wire configurations in pediatric supracondylar humerus fractures.","authors":"Abdulkadir Muhammed Bulut, Sancar Bakircioglu, Elif Naz Perdeci, Teyfik Demir, Fatma Kubra Erbay Elibol, Güney Yilmaz","doi":"10.1097/BPB.0000000000001359","DOIUrl":null,"url":null,"abstract":"<p><p>Supracondylar humerus fractures are common pediatric injuries requiring surgical fixation. Beyond technical factors, medial column comminution may substantially influence construct stability, yet its biomechanical impact across different three-pin configurations remains unclear. One hundred twenty synthetic humeri were assigned to six groups (n = 20). Medial comminution was simulated by 25% (small) or 50% (large) wedge removal. Three lateral divergent pinning (3LDP) and two lateral one medial crossed pinning (3XP) configurations were tested under varus bending, torsion, and photographic displacement analysis. In torsional testing, the 3XP configuration showed significantly greater stiffness and maximum torque than 3LDP across all wedge sizes (P < 0.005), including the intact condition (stiffness: 1.19 ± 0.29 vs. 0.51 ± 0.16 Nm/°; maximum torque: 10.70 ± 2.22 vs. 5.37 ± 1.59 Nm). In varus bending, large wedge removal significantly reduced maximum load in the 3LDP group (256.58 ± 50.26 vs. 214.03 ± 37.22 N; P = 0.045), while no wedge-related differences were observed in the 3XP configuration. Fracture-line displacement increased with wedge removal in both constructs (e.g. 0.88 ± 0.41 to 2.23 ± 0.40 mm in 3LDP; P < 0.001); wedge size significantly affected displacement in 3LDP, whereas in the 3XP configuration, displacement increased with wedge removal but did not differ significantly between small and large wedge sizes. Increasing medial comminution negatively affected stability, particularly in lateral-only three-pin fixation. 3XP constructs showed greater torsional resistance and preserved varus stability in this synthetic model. These findings provide biomechanical insight into fixation behavior in unstable supracondylar fractures.</p>","PeriodicalId":50092,"journal":{"name":"Journal of Pediatric Orthopaedics-Part B","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2026-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics-Part B","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPB.0000000000001359","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Supracondylar humerus fractures are common pediatric injuries requiring surgical fixation. Beyond technical factors, medial column comminution may substantially influence construct stability, yet its biomechanical impact across different three-pin configurations remains unclear. One hundred twenty synthetic humeri were assigned to six groups (n = 20). Medial comminution was simulated by 25% (small) or 50% (large) wedge removal. Three lateral divergent pinning (3LDP) and two lateral one medial crossed pinning (3XP) configurations were tested under varus bending, torsion, and photographic displacement analysis. In torsional testing, the 3XP configuration showed significantly greater stiffness and maximum torque than 3LDP across all wedge sizes (P < 0.005), including the intact condition (stiffness: 1.19 ± 0.29 vs. 0.51 ± 0.16 Nm/°; maximum torque: 10.70 ± 2.22 vs. 5.37 ± 1.59 Nm). In varus bending, large wedge removal significantly reduced maximum load in the 3LDP group (256.58 ± 50.26 vs. 214.03 ± 37.22 N; P = 0.045), while no wedge-related differences were observed in the 3XP configuration. Fracture-line displacement increased with wedge removal in both constructs (e.g. 0.88 ± 0.41 to 2.23 ± 0.40 mm in 3LDP; P < 0.001); wedge size significantly affected displacement in 3LDP, whereas in the 3XP configuration, displacement increased with wedge removal but did not differ significantly between small and large wedge sizes. Increasing medial comminution negatively affected stability, particularly in lateral-only three-pin fixation. 3XP constructs showed greater torsional resistance and preserved varus stability in this synthetic model. These findings provide biomechanical insight into fixation behavior in unstable supracondylar fractures.
期刊介绍:
The journal highlights important recent developments from the world''s leading clinical and research institutions. The journal publishes peer-reviewed papers on the diagnosis and treatment of pediatric orthopedic disorders.
It is the official journal of IFPOS (International Federation of Paediatric Orthopaedic Societies).
Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.