{"title":"Endoscopic removal of a press-through pack from the small bowel using double-balloon enteroscopy","authors":"Maki Akabane MD , Akiyoshi Tsuboi MD, PhD , Shuhei Sugata MD , Shuya Shigenobu MD , Ken Yamashita MD, PhD , Toshio Kuwai MD, PhD , Shiro Oka MD, PhD","doi":"10.1016/j.vgie.2026.01.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and Aims</h3><div>Press-through packs (PTPs) are a common cause of foreign body ingestion; however, their retention in the small bowel is rare. We present a case in which a PTP lodged at a stenotic site was safely removed using a double-balloon endoscope (DBE).</div></div><div><h3>Methods</h3><div>A 73-year-old woman with a history of ileal tuberculosis and resultant small-bowel stenosis presented with abdominal pain. CT revealed a high-density object in the lower abdomen, suspicious for a foreign body. A retrograde DBE approach was subsequently performed and revealed a PTP lodged in the ileum near the site of stenosis.</div></div><div><h3>Results</h3><div>The PTP was grasped using biopsy forceps, repositioned with a retrieval net, and extracted through the overtube using DBE, with the tip balloon secured by a nylon thread. There were no adverse events during or after the procedure. The patient’s symptoms resolved immediately after removal, and no surgical intervention was required.</div></div><div><h3>Conclusions</h3><div>This case demonstrates the utility of DBE, with the tip balloon secured by a nylon thread, in retrieving retained sharp foreign bodies such as PTP. This method enables the safe retrieval of sharp foreign bodies in the small bowel that can be contained within the overtube.</div></div>","PeriodicalId":55855,"journal":{"name":"VideoGIE","volume":"11 6","pages":"Pages 259-263"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"VideoGIE","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468448126000032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background and Aims
Press-through packs (PTPs) are a common cause of foreign body ingestion; however, their retention in the small bowel is rare. We present a case in which a PTP lodged at a stenotic site was safely removed using a double-balloon endoscope (DBE).
Methods
A 73-year-old woman with a history of ileal tuberculosis and resultant small-bowel stenosis presented with abdominal pain. CT revealed a high-density object in the lower abdomen, suspicious for a foreign body. A retrograde DBE approach was subsequently performed and revealed a PTP lodged in the ileum near the site of stenosis.
Results
The PTP was grasped using biopsy forceps, repositioned with a retrieval net, and extracted through the overtube using DBE, with the tip balloon secured by a nylon thread. There were no adverse events during or after the procedure. The patient’s symptoms resolved immediately after removal, and no surgical intervention was required.
Conclusions
This case demonstrates the utility of DBE, with the tip balloon secured by a nylon thread, in retrieving retained sharp foreign bodies such as PTP. This method enables the safe retrieval of sharp foreign bodies in the small bowel that can be contained within the overtube.
期刊介绍:
VideoGIE, an official video journal of the American Society for Gastrointestinal Endoscopy, is an Open Access, online-only journal to serve patients with digestive diseases. VideoGIE publishes original, single-blinded peer-reviewed video case reports and case series of endoscopic procedures used in the study, diagnosis, and treatment of digestive diseases. Videos demonstrate use of endoscopic systems, devices, and techniques; report outcomes of endoscopic interventions; and educate physicians and patients about gastrointestinal endoscopy. VideoGIE serves the educational needs of endoscopists in training as well as advanced endoscopists, endoscopy staff and industry, and patients. VideoGIE brings video commentaries from experts, legends, committees, and leadership of the society. Careful adherence to submission guidelines will avoid unnecessary delays, as incomplete submissions may be returned to the authors before initiation of the peer review process.