FoundDiff: Foundational Diffusion Model for Generalizable Low-Dose CT Denoising

IEEE transactions on medical imaging Pub Date : 2026-08-01 Epub Date: 2026-06-01 DOI:10.1109/TMI.2026.3698474
Zhihao Chen;Qi Gao;Zilong Li;Junping Zhang;Yi Zhang;Jun Zhao;Hongming Shan
{"title":"FoundDiff: Foundational Diffusion Model for Generalizable Low-Dose CT Denoising","authors":"Zhihao Chen;Qi Gao;Zilong Li;Junping Zhang;Yi Zhang;Jun Zhao;Hongming Shan","doi":"10.1109/TMI.2026.3698474","DOIUrl":null,"url":null,"abstract":"Low-dose computed tomography (CT) denoising is crucial for reduced radiation exposure while ensuring diagnostically acceptable image quality. Despite significant advancements driven by deep learning (DL) in recent years, existing DL-based methods, typically trained on a specific dose level and anatomical region, struggle to handle diverse noise characteristics and anatomical heterogeneity during varied scanning conditions, limiting their generalizability and robustness in clinical scenarios. In this paper, we propose FoundDiff, a foundational diffusion model for unified and generalizable LDCT denoising across various dose levels and anatomical regions. FoundDiff employs a two-stage strategy: <bold>(i) </b> dose-anatomy perception and <bold>(ii)</b> adaptive denoising. First, we develop a dose- and anatomy-aware contrastive language-image pre-training model (DA-CLIP) to achieve robust dose and anatomy perception by leveraging specialized contrastive learning strategies to learn continuous representations that quantify ordinal dose variations and identify salient anatomical regions. Second, we design a dose- and anatomy-aware diffusion model (DA-Diff) to perform adaptive and generalizable denoising by synergistically integrating the learned dose and anatomy embeddings from DA-CLIP into diffusion process via a novel dose and anatomy conditional block (DACB) based on Mamba. Extensive experiments on a large simulated multi-dose CT dataset spanning three anatomical regions, together with cross-dataset evaluations on Mayo-2016, CQ500, and piglet datasets, demonstrate superior denoising performance and strong generalization to unseen dose levels and anatomical regions. The codes and models are available at <uri>https://github.com/hao1635/FoundDiff</uri>","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"45 8","pages":"4366-4379"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11541237/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Low-dose computed tomography (CT) denoising is crucial for reduced radiation exposure while ensuring diagnostically acceptable image quality. Despite significant advancements driven by deep learning (DL) in recent years, existing DL-based methods, typically trained on a specific dose level and anatomical region, struggle to handle diverse noise characteristics and anatomical heterogeneity during varied scanning conditions, limiting their generalizability and robustness in clinical scenarios. In this paper, we propose FoundDiff, a foundational diffusion model for unified and generalizable LDCT denoising across various dose levels and anatomical regions. FoundDiff employs a two-stage strategy: (i) dose-anatomy perception and (ii) adaptive denoising. First, we develop a dose- and anatomy-aware contrastive language-image pre-training model (DA-CLIP) to achieve robust dose and anatomy perception by leveraging specialized contrastive learning strategies to learn continuous representations that quantify ordinal dose variations and identify salient anatomical regions. Second, we design a dose- and anatomy-aware diffusion model (DA-Diff) to perform adaptive and generalizable denoising by synergistically integrating the learned dose and anatomy embeddings from DA-CLIP into diffusion process via a novel dose and anatomy conditional block (DACB) based on Mamba. Extensive experiments on a large simulated multi-dose CT dataset spanning three anatomical regions, together with cross-dataset evaluations on Mayo-2016, CQ500, and piglet datasets, demonstrate superior denoising performance and strong generalization to unseen dose levels and anatomical regions. The codes and models are available at https://github.com/hao1635/FoundDiff
可推广的低剂量CT去噪的基本扩散模型。
低剂量计算机断层扫描(CT)去噪对于减少辐射暴露,同时确保诊断上可接受的图像质量至关重要。尽管近年来深度学习(DL)取得了重大进展,但现有的基于深度学习的方法通常在特定剂量水平和解剖区域进行训练,难以处理不同扫描条件下的不同噪声特征和解剖异质性,限制了其在临床场景中的通用性和稳健性。在本文中,我们提出了FoundDiff,一个基本的扩散模型,用于统一和推广LDCT在不同剂量水平和解剖区域的去噪。FoundDiff采用两阶段策略:(i)剂量解剖感知和(ii)自适应去噪。首先,我们开发了一个剂量和解剖感知的对比语言图像预训练模型(DA-CLIP),通过利用专门的对比学习策略来学习量化顺序剂量变化和识别显著解剖区域的连续表征,从而实现稳健的剂量和解剖感知。其次,我们设计了一个剂量和解剖敏感的扩散模型(DA-Diff),通过基于曼巴的新型剂量和解剖条件块(DACB)将从DA-CLIP中学习到的剂量和解剖嵌入协同整合到扩散过程中,从而实现自适应和可泛化的去噪。在跨越三个解剖区域的大型模拟多剂量CT数据集上进行的大量实验,以及对Mayo-2016、CQ500和仔猪数据集的交叉数据集评估,证明了卓越的去噪性能和对未见剂量水平和解剖区域的强泛化。代码和模型可在https: //github.com/hao1635/FoundDiff上获得。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书