{"title":"Dosimetric impact of computational grid resolution and range pull-back on carbon-ion treatment planning.","authors":"Yixiao Guo, Hongyi Cai, Xinguo Liu, Zhiguo Xu","doi":"10.1016/j.meddos.2026.05.001","DOIUrl":null,"url":null,"abstract":"<p><p>The effectiveness of carbon ion radiotherapy (C-ion RT) is influenced by the computational grid resolution and range-modulation strategies used during treatment planning. The study aimed to evaluate the dosimetric effects of grid resolution and range pull-back (shift) on tumor target coverage and organs-at-risk (OARs) sparing, establish the anatomical site-specific range safety margins or error tolerance. Dose-volume parameters for spot-scanning (SS) and uniform-scanning (US) carbon ion plans were evaluated using an in-house treatment planning system (TPS) at grid resolutions of 1 to 4 mm. A range pull-back, intentionally set between 1 and 5 mm in 1-mm increments, was introduced. Logistic regression models were employed to characterize the dose response relationships between range pull-back and dose metrics of target and OARs. US plans demonstrated relatively stable target coverage in D<sub>95</sub> and D<sub>98</sub> metrics (ΔD<sub>95US</sub> = 0.12 %, ΔD<sub>98US</sub> = 0.86 % when comparing 4 to 1 mm grids), whereas SS plans showed a slight decline in these coverage metrics (ΔD<sub>95SS</sub> = 1.09 %, ΔD<sub>98SS</sub> = 1.59 % for 4 mm versus 1 mm grids). OAR dose-volume parameters remained highly consistent at 1 to 2 mm grids but exhibited significant deviations at 3 to 4 mm grids. The range safety margins were routinely established as ±1 mm for thoracic targets, ±2 mm for head-and-neck targets, ±3 mm for abdominal targets, and ±2 to 3 mm for pelvic targets. Based on our findings, a 2 mm computational grid is recommended in most clinical scenarios of carbon ion radiotherapy, and a 1 mm grid is preferred for targets adjacent to serial OARs or small targets near critical OARs. Implementing anatomic site-specific range safety margins can reduce radiation-induced adverse events while preserving relative biological effectiveness (RBE)-weighted dose coverage within the tumor target.</p>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.meddos.2026.05.001","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
The effectiveness of carbon ion radiotherapy (C-ion RT) is influenced by the computational grid resolution and range-modulation strategies used during treatment planning. The study aimed to evaluate the dosimetric effects of grid resolution and range pull-back (shift) on tumor target coverage and organs-at-risk (OARs) sparing, establish the anatomical site-specific range safety margins or error tolerance. Dose-volume parameters for spot-scanning (SS) and uniform-scanning (US) carbon ion plans were evaluated using an in-house treatment planning system (TPS) at grid resolutions of 1 to 4 mm. A range pull-back, intentionally set between 1 and 5 mm in 1-mm increments, was introduced. Logistic regression models were employed to characterize the dose response relationships between range pull-back and dose metrics of target and OARs. US plans demonstrated relatively stable target coverage in D95 and D98 metrics (ΔD95US = 0.12 %, ΔD98US = 0.86 % when comparing 4 to 1 mm grids), whereas SS plans showed a slight decline in these coverage metrics (ΔD95SS = 1.09 %, ΔD98SS = 1.59 % for 4 mm versus 1 mm grids). OAR dose-volume parameters remained highly consistent at 1 to 2 mm grids but exhibited significant deviations at 3 to 4 mm grids. The range safety margins were routinely established as ±1 mm for thoracic targets, ±2 mm for head-and-neck targets, ±3 mm for abdominal targets, and ±2 to 3 mm for pelvic targets. Based on our findings, a 2 mm computational grid is recommended in most clinical scenarios of carbon ion radiotherapy, and a 1 mm grid is preferred for targets adjacent to serial OARs or small targets near critical OARs. Implementing anatomic site-specific range safety margins can reduce radiation-induced adverse events while preserving relative biological effectiveness (RBE)-weighted dose coverage within the tumor target.
期刊介绍:
Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.