Investigation of Fill-Finish Tubing Compatibility in the Absence of Protein Stabilizers.

Q3 Medicine
Stephanie K Vargas, Saeed Moshashaee, Teruna J Siahaan
{"title":"Investigation of Fill-Finish Tubing Compatibility in the Absence of Protein Stabilizers.","authors":"Stephanie K Vargas, Saeed Moshashaee, Teruna J Siahaan","doi":"10.5731/pdajpst.2025-000014.1","DOIUrl":null,"url":null,"abstract":"<p><p>Optimization of the fill-finish process for a biotherapeutic is imperative for the highest quality drug product. Fill-finish is the last step in manufacturing and the last opportunity for intervention prior to entry into the supply chain. Typically, stabilizing excipients are utilized to mitigate the chemical or structural weaknesses of a protein therapeutic; however, there are cases in which the route of administration dictates the exclusion of key stabilizing excipients. When this is the case, process-related stabilization techniques need additional investigation. The goal of this work is to provide guidance and highlight key factors impacting enzyme stability in fill-finish processes in the absence of stabilizing excipients. Four tubing interfaces were studied in a recirculation model grouped as either silicone or thermoplastic elastomer. Colloidal stability was found to be the main route of degradation for this enzyme, producing soluble and insoluble aggregate, and various methods were employed to measure and characterize aggregation across a large dynamic size range. The flow imaging data captured high levels of particles that were shed from the thermoplastic elastomer tubing material in the 1-100 µm size range. Size-exclusion chromatography also indicated that the thermoplastic elastomer tubing produced unique multimeric soluble aggregates of the enzyme. Silicone tubing demonstrated superior performance compared to thermoplastic tubing in recirculation models. Silicone tubing produced a very low amount of subvisible particulate shedding with undetectable multimeric aggregate species as well as a better overall visual appearance after recirculation for up to 4 hours. The instability of the enzyme solution was not related to the shear stress in a flow field alone, but rather it was due to the use of an incompatible tubing material in the fill-finish process.</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":" ","pages":"372-384"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2025-000014.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Optimization of the fill-finish process for a biotherapeutic is imperative for the highest quality drug product. Fill-finish is the last step in manufacturing and the last opportunity for intervention prior to entry into the supply chain. Typically, stabilizing excipients are utilized to mitigate the chemical or structural weaknesses of a protein therapeutic; however, there are cases in which the route of administration dictates the exclusion of key stabilizing excipients. When this is the case, process-related stabilization techniques need additional investigation. The goal of this work is to provide guidance and highlight key factors impacting enzyme stability in fill-finish processes in the absence of stabilizing excipients. Four tubing interfaces were studied in a recirculation model grouped as either silicone or thermoplastic elastomer. Colloidal stability was found to be the main route of degradation for this enzyme, producing soluble and insoluble aggregate, and various methods were employed to measure and characterize aggregation across a large dynamic size range. The flow imaging data captured high levels of particles that were shed from the thermoplastic elastomer tubing material in the 1-100 µm size range. Size-exclusion chromatography also indicated that the thermoplastic elastomer tubing produced unique multimeric soluble aggregates of the enzyme. Silicone tubing demonstrated superior performance compared to thermoplastic tubing in recirculation models. Silicone tubing produced a very low amount of subvisible particulate shedding with undetectable multimeric aggregate species as well as a better overall visual appearance after recirculation for up to 4 hours. The instability of the enzyme solution was not related to the shear stress in a flow field alone, but rather it was due to the use of an incompatible tubing material in the fill-finish process.

无蛋白质稳定剂情况下填充-精加工管相容性的研究。
生物治疗药物的补全过程优化是获得高质量药品的必要条件。补成品是制造的最后一步,也是进入供应链之前进行干预的最后机会。通常,稳定赋形剂用于减轻蛋白质治疗的化学或结构缺陷;然而,有些情况下,当给药路线规定排除关键的稳定辅料。在这种情况下,需要对工艺相关的稳定技术进行额外的研究。这项工作的目的是提供指导,并强调在没有稳定辅料的情况下影响补精过程中酶稳定性的关键因素。在一个再循环模型中研究了四种管道界面,分为硅酮或热塑性弹性体。胶体稳定性被发现是该酶降解的主要途径,产生可溶性和不溶性聚集体,并采用各种方法在大的动态尺寸范围内测量和表征聚集体。流动成像数据捕获了1-100 μ m尺寸范围内从热塑性弹性体管材料中脱落的高水平颗粒。尺寸排除色谱也表明热塑性弹性体管产生独特的多聚体可溶性聚集体的酶。硅胶管在再循环模型中表现出比热塑性管优越的性能。硅胶管产生了极少量的不可见颗粒脱落,具有不可检测的多聚体聚集体,并且在再循环长达4小时后具有更好的整体视觉外观。酶溶液的不稳定性不仅仅与流场中的剪切应力有关,而是由于填充过程中使用了不相容的管材。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
34
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书