Impact of Storage Orientation and Duration on Prefilled Syringe Performance: Break-Loose and Glide Forces, and Injection Time Across Multiple Time Points.

Q3 Medicine
Vincent Mensah, Samira Munkaila, Hao Wang, Björn-Hendrik Peters, George Currier, Christina Evans, Yusuf Oni, Ankur Kulshrestha, Olga Yee, Joseph Rinella, Trella Mitchell
{"title":"Impact of Storage Orientation and Duration on Prefilled Syringe Performance: Break-Loose and Glide Forces, and Injection Time Across Multiple Time Points.","authors":"Vincent Mensah, Samira Munkaila, Hao Wang, Björn-Hendrik Peters, George Currier, Christina Evans, Yusuf Oni, Ankur Kulshrestha, Olga Yee, Joseph Rinella, Trella Mitchell","doi":"10.5731/pdajpst.2025-000069.1","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigates the dynamics of break loose glide force (BLGF) in prefilled syringes (PFS) and injection time in autoinjectors (AI) across different orientations and time points, focusing on their impact on drug delivery performance. PFS and Autoinjectors are pivotal in modern therapeutics, enabling precise administration of biologics, vaccines, and other sensitive pharmaceuticals. Patients with chronic conditions and individuals with limited dexterity requiring frequent self-administration, all benefit from devices that minimize BLGF to ensure consistent injection times. To explore the influence of storage orientation (tip-up vs. tip-down) and time on these devices, we conducted a comprehensive evaluation over a 12-month period supplemented by reference timepoint samples. Utilizing a dual-orientational framework, PFS and autoinjectors were stored under controlled conditions to assess orientation-dependent performance. Aged and empty samples served as reference controls. The study's primary metrics included BLGF, which is the initial force required to initiate plunger movement then enable injection along the barrel, and injection time. These parameters were analyzed using a calibrated Zwick/Roell mechanical tester under controlled environmental conditions.Key findings reveal statistically significant but not practically impactful effects of storage orientation on BLGF or injection time across all tested intervals. Minor time-based variations were noted, with BLGF shifts being less than 1 N and injection time deviations under 2 seconds. These changes indicated no practical significance or risk of out-of-specification performance. The Analysis of variance (ANOVA) analysis confirmed no evidence suggesting orientation affects functionality.This work demonstrates that short to mid-term storage conditions do not adversely affect device performance, providing critical assurance for manufacturers, regulators, and end-users. The study highlights the robustness of PFS and Autoinjectors against orientation and temporal changes, mitigating risks associated with handling variability and optimizing supply chain logistics. Future research should extend these findings to longer durations to confirm long-term stability.</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2025-000069.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigates the dynamics of break loose glide force (BLGF) in prefilled syringes (PFS) and injection time in autoinjectors (AI) across different orientations and time points, focusing on their impact on drug delivery performance. PFS and Autoinjectors are pivotal in modern therapeutics, enabling precise administration of biologics, vaccines, and other sensitive pharmaceuticals. Patients with chronic conditions and individuals with limited dexterity requiring frequent self-administration, all benefit from devices that minimize BLGF to ensure consistent injection times. To explore the influence of storage orientation (tip-up vs. tip-down) and time on these devices, we conducted a comprehensive evaluation over a 12-month period supplemented by reference timepoint samples. Utilizing a dual-orientational framework, PFS and autoinjectors were stored under controlled conditions to assess orientation-dependent performance. Aged and empty samples served as reference controls. The study's primary metrics included BLGF, which is the initial force required to initiate plunger movement then enable injection along the barrel, and injection time. These parameters were analyzed using a calibrated Zwick/Roell mechanical tester under controlled environmental conditions.Key findings reveal statistically significant but not practically impactful effects of storage orientation on BLGF or injection time across all tested intervals. Minor time-based variations were noted, with BLGF shifts being less than 1 N and injection time deviations under 2 seconds. These changes indicated no practical significance or risk of out-of-specification performance. The Analysis of variance (ANOVA) analysis confirmed no evidence suggesting orientation affects functionality.This work demonstrates that short to mid-term storage conditions do not adversely affect device performance, providing critical assurance for manufacturers, regulators, and end-users. The study highlights the robustness of PFS and Autoinjectors against orientation and temporal changes, mitigating risks associated with handling variability and optimizing supply chain logistics. Future research should extend these findings to longer durations to confirm long-term stability.

储存方向和持续时间对预充注射器性能的影响:跨多个时间点的断裂和滑动力以及注射时间。
本研究研究了预充式注射器(PFS)的断裂滑动力(BLGF)和自动注射器(AI)的注射时间在不同方向和时间点上的动态变化,重点研究了它们对药物输送性能的影响。PFS和自动注射器在现代治疗中至关重要,可以精确给药生物制剂、疫苗和其他敏感药物。慢性疾病患者和需要频繁自我给药的灵活性有限的个体都受益于最小化BLGF的设备,以确保一致的注射时间。为了探索存储方向(向上或向下)和时间对这些设备的影响,我们进行了为期12个月的综合评估,并辅以参考时间点样本。利用双取向框架,PFS和自动进样器在受控条件下存储,以评估取向依赖的性能。陈年和空样品作为对照。该研究的主要指标包括BLGF和注入时间。BLGF是启动柱塞运动并实现沿管柱注入所需的初始力。在受控环境条件下,使用校准的Zwick/Roell机械测试仪分析这些参数。主要研究结果显示,在所有测试区间,储存方向对BLGF或注入时间的影响具有统计学意义,但没有实际影响。注意到基于时间的微小变化,BLGF位移小于1 N,注射时间偏差小于2秒。这些更改没有实际意义,也没有超出规格性能的风险。方差分析(ANOVA)分析证实没有证据表明取向影响功能。这项工作表明,短期到中期的存储条件不会对设备性能产生不利影响,为制造商、监管机构和最终用户提供了关键的保证。该研究强调了PFS和自动进样器对方向和时间变化的鲁棒性,降低了与处理可变性相关的风险,并优化了供应链物流。未来的研究应该将这些发现扩展到更长的时间,以确认长期的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
34
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书