Development of an automated radiosynthesis for [68Ga]Ga-NODAGA[40Lys]-Exendin-4 in sodium acetate buffer

IF 3.7 Q1 CHEMISTRY, INORGANIC & NUCLEAR
EJNMMI Radiopharmacy and Chemistry Pub Date : 2026-06-01 Epub Date: 2026-08-05 DOI:10.1186/s41181-026-00452-0
Maïlys Ragot, Pauline Reynaud-Orhon, Alban Revy, Marie Batisse-Lignier, Valentin Brusseau, Antony Kelly, Hosameldin Otman, Florent Cachin, Marion Chanchou, Sophie Levesque, Marion Tempier
{"title":"Development of an automated radiosynthesis for [68Ga]Ga-NODAGA[40Lys]-Exendin-4 in sodium acetate buffer","authors":"Maïlys Ragot,&nbsp;Pauline Reynaud-Orhon,&nbsp;Alban Revy,&nbsp;Marie Batisse-Lignier,&nbsp;Valentin Brusseau,&nbsp;Antony Kelly,&nbsp;Hosameldin Otman,&nbsp;Florent Cachin,&nbsp;Marion Chanchou,&nbsp;Sophie Levesque,&nbsp;Marion Tempier","doi":"10.1186/s41181-026-00452-0","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>[<sup>68</sup>Ga]Ga-NODAGA[40Lys]-Exendin-4 (<sup>68</sup>Ga-Ex-4) is a new PET radiopharmaceutical targeting GLP-1-R that showed great specificity and sensitivity in the topographic diagnosis of benign insulinoma. We herein report the development of a new method for <sup>68</sup>Ga-Ex-4 radiolabeling in sodium acetate buffer, automated on the miniAllinOne synthesizer.</p><h3>Results</h3><p>Key parameters were reaction volume, due to low amount of peptide, and pH. At a reaction volume of 2.65 mL and pH 2.9, the reaction yielded 80% of <sup>68</sup>Ga-Ex-4. The use of polysorbate and cooling of the solution allows to decrease the adsorption on the reaction vial (from 29 to 2% of total activity remaining on the vial). <sup>68</sup>Ga-Ex-4 is purified on a HLB cartridge. Final product was obtained within 40 min, with a mean radiochemical purity of 97% and a radiochemical yield of 67%.</p><h3>Conclusions</h3><p>We have successfully developed a new radiolabeling method for [<sup>68</sup>Ga]Ga-NODAGA-[40Lys]Exendin-4, automated on a miniAllinOne synthesizer and using sodium acetate buffer, suitable for clinical application.</p></div>","PeriodicalId":534,"journal":{"name":"EJNMMI Radiopharmacy and Chemistry","volume":"11 1","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13437812/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Radiopharmacy and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s41181-026-00452-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

Background

[68Ga]Ga-NODAGA[40Lys]-Exendin-4 (68Ga-Ex-4) is a new PET radiopharmaceutical targeting GLP-1-R that showed great specificity and sensitivity in the topographic diagnosis of benign insulinoma. We herein report the development of a new method for 68Ga-Ex-4 radiolabeling in sodium acetate buffer, automated on the miniAllinOne synthesizer.

Results

Key parameters were reaction volume, due to low amount of peptide, and pH. At a reaction volume of 2.65 mL and pH 2.9, the reaction yielded 80% of 68Ga-Ex-4. The use of polysorbate and cooling of the solution allows to decrease the adsorption on the reaction vial (from 29 to 2% of total activity remaining on the vial). 68Ga-Ex-4 is purified on a HLB cartridge. Final product was obtained within 40 min, with a mean radiochemical purity of 97% and a radiochemical yield of 67%.

Conclusions

We have successfully developed a new radiolabeling method for [68Ga]Ga-NODAGA-[40Lys]Exendin-4, automated on a miniAllinOne synthesizer and using sodium acetate buffer, suitable for clinical application.

醋酸钠缓冲液中[68Ga]Ga-NODAGA[40Lys]-Exendin-4的自动放射性合成
背景:[68Ga]Ga-NODAGA[40Lys]-Exendin-4 (68Ga- ex -4)是一种靶向GLP-1-R的新型PET放射性药物,在良性胰岛素瘤的影像学诊断中具有很高的特异性和敏感性。本文报道了一种在醋酸钠缓冲液中进行68Ga-Ex-4放射性标记的新方法,该方法在miniAllinOne合成器上自动进行。结果:关键参数为反应体积和pH,因为多肽量少。反应体积为2.65 mL, pH为2.9时,68Ga-Ex-4的收率为80%。使用聚山梨酸酯和冷却溶液可以减少反应瓶上的吸附(从瓶上剩余总活性的29%到2%)。68Ga-Ex-4在HLB滤筒上纯化。最终产物在40分钟内获得,平均放射化学纯度为97%,放射化学产率为67%。结论:我们成功开发了一种新的[68Ga]Ga-NODAGA-[40Lys]Exendin-4的放射性标记方法,该方法在miniAllinOne合成器上自动化,使用醋酸钠缓冲液,适合临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
8.70%
发文量
30
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书