RVDeformer: Sparse Point Cloud-Guided Right Ventricle 3-D Reconstruction in Echocardiograms

IEEE transactions on medical imaging Pub Date : 2026-08-01 Epub Date: 2026-03-25 DOI:10.1109/TMI.2026.3696549
Zhaohui Wang;Jun Shi;Minfan Zhao;Ziqi Zhu;Yida Li;Hong An
{"title":"RVDeformer: Sparse Point Cloud-Guided Right Ventricle 3-D Reconstruction in Echocardiograms","authors":"Zhaohui Wang;Jun Shi;Minfan Zhao;Ziqi Zhu;Yida Li;Hong An","doi":"10.1109/TMI.2026.3696549","DOIUrl":null,"url":null,"abstract":"3D reconstruction of the Right Ventricle (RV) from echocardiograms is crucial for accurate clinical evaluation of cardiac function. However, existing methods are hindered by the complex RV anatomy and the incomplete spatial information inherent in 2D multi-view echocardiograms. Therefore, we propose RVDeformer, a sparse point cloud-guided framework for RV 3D reconstruction. RVDeformer reformulates the reconstruction task as a mesh deformation problem, learning to deform a predefined template mesh to match the target structure under the guidance of the sparse anatomical point cloud. Specifically, this framework employs the end-to-end neural network RVDeformNet to extract the features of the point cloud and template mesh for predicting the displacement of each mesh vertex. We design a point cloud-mesh fusion module that can effectively align and fuse features from the two modalities to enhance the representation ability of the model. We conduct extensive validation on a clinical dataset of 1,278 cases and demonstrate that RVDeformer outperforms existing state-of-the-art methods, achieving a Chamfer Distance (CD) of <inline-formula> <tex-math>$2.24\\pm 0.55$ </tex-math></inline-formula> mm, an F1-score of <inline-formula> <tex-math>$0.74\\pm 0.10$ </tex-math></inline-formula> at the 3 mm threshold, and a Volumetric Similarity (VS) of <inline-formula> <tex-math>$91.53\\pm 2.28$ </tex-math></inline-formula>%, with significant potential for clinical applications. The code is available at <uri>https://github.com/onezh95/RVDeformer</uri>","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"45 8","pages":"4240-4253"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11534908/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/25 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

3D reconstruction of the Right Ventricle (RV) from echocardiograms is crucial for accurate clinical evaluation of cardiac function. However, existing methods are hindered by the complex RV anatomy and the incomplete spatial information inherent in 2D multi-view echocardiograms. Therefore, we propose RVDeformer, a sparse point cloud-guided framework for RV 3D reconstruction. RVDeformer reformulates the reconstruction task as a mesh deformation problem, learning to deform a predefined template mesh to match the target structure under the guidance of the sparse anatomical point cloud. Specifically, this framework employs the end-to-end neural network RVDeformNet to extract the features of the point cloud and template mesh for predicting the displacement of each mesh vertex. We design a point cloud-mesh fusion module that can effectively align and fuse features from the two modalities to enhance the representation ability of the model. We conduct extensive validation on a clinical dataset of 1,278 cases and demonstrate that RVDeformer outperforms existing state-of-the-art methods, achieving a Chamfer Distance (CD) of $2.24\pm 0.55$ mm, an F1-score of $0.74\pm 0.10$ at the 3 mm threshold, and a Volumetric Similarity (VS) of $91.53\pm 2.28$ %, with significant potential for clinical applications. The code is available at https://github.com/onezh95/RVDeformer
RVDeformer:稀疏点云引导下的超声心动图右心室三维重建。
超声心动图对右心室(RV)的三维重建对于临床准确评估心功能至关重要。然而,现有的方法受到复杂的右心室解剖结构和二维多视图超声心动图固有的不完整空间信息的阻碍。因此,我们提出了RVDeformer,一个稀疏点云引导的RV三维重建框架。RVDeformer将重构任务重新定义为网格变形问题,在稀疏解剖点云的指导下学习对预定义模板网格进行变形以匹配目标结构。具体而言,该框架采用端到端神经网络RVDeformNet提取点云和模板网格的特征,用于预测每个网格顶点的位移。我们设计了一个点云-网格融合模块,可以有效地对齐和融合两种模式的特征,以增强模型的表示能力。我们对1,278例临床数据集进行了广泛的验证,并证明RVDeformer优于现有的最先进的方法,实现了2.24±0.55 mm的Chamfer Distance (CD),在3 mm阈值下的f1得分为0.74±0.10,体积相似性(VS)为91.53±2.28%,具有显著的临床应用潜力。代码可在https://github.com/onezh95/RVDeformer上获得。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书