Luka Pušnik MD, Natalie Winter MD, Maks Matej Cuzak, Igor Serša PhD, Nejc Umek MD, PhD, Žiga Snoj MD, PhD, Gregor Omejec PT, PhD
{"title":"The Influence of Evaluator Experience, Dynamic Versus Static Ultrasound Image Interpretation, and Probe Frequency on Fascicle Differentiation","authors":"Luka Pušnik MD, Natalie Winter MD, Maks Matej Cuzak, Igor Serša PhD, Nejc Umek MD, PhD, Žiga Snoj MD, PhD, Gregor Omejec PT, PhD","doi":"10.1016/j.jhsa.2026.04.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To determine the influence of evaluator experience, dynamic versus static ultrasound (US) image interpretation, and probe frequency on fascicle differentiation.</div></div><div><h3>Methods</h3><div>Evaluator experience and dynamic versus static US image interpretation were assessed on 12 cadaveric forearms. Median nerves were scanned using a 23-MHz US probe, followed by nerve excision and high-field magnetic resonance imaging (MRI) at 9.4-T. Five independent evaluators with different experience levels delineated fascicles twice, using static and dynamic US images. Delineations were compared with high-field MRI. The influence of probe frequency was evaluated on 12 median nerves of healthy volunteers. Median nerves at wrist were scanned using 14-, 18-, 24-, and 70-MHz US probes. Images were cross-referenced, and fascicle counts were compared relative to the highest-frequency probe.</div></div><div><h3>Results</h3><div>Dynamic imaging improved fascicle differentiation by 27.6% to 51.2% compared to static (<em>P</em> < .001), with a greater benefit for less experienced evaluators. The most experienced evaluator identified on average 62.3% more fascicles in dynamic assessment compared to the least experienced. The 70-MHz probe showed the highest mean fascicle count (27.6 ± 3.7), while 24-, 18-, and 14-MHz probes differentiated 26%, 46%, and 63% fewer fascicles, respectively (<em>P</em> <. 0001).</div></div><div><h3>Conclusions</h3><div>Fascicle differentiation improves significantly with evaluator experience, using dynamic US image interpretation, and higher probe frequency. These findings support the clinical utility of ultrahigh-frequency US for detailed evaluation of superficial nerves.</div></div><div><h3>Clinical relevance</h3><div>Experience and dynamic image interpretation are important for reliable fascicle recognition and to minimize misinterpretation. Ultrahigh-frequency US probes substantially improve fascicle differentiation, but their limited penetration requires careful selection of probe frequency based on nerve depth.</div></div>","PeriodicalId":54815,"journal":{"name":"Journal of Hand Surgery-American Volume","volume":"51 9","pages":"Pages 983.e1-983.e9"},"PeriodicalIF":2.4000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery-American Volume","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0363502326003096","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To determine the influence of evaluator experience, dynamic versus static ultrasound (US) image interpretation, and probe frequency on fascicle differentiation.
Methods
Evaluator experience and dynamic versus static US image interpretation were assessed on 12 cadaveric forearms. Median nerves were scanned using a 23-MHz US probe, followed by nerve excision and high-field magnetic resonance imaging (MRI) at 9.4-T. Five independent evaluators with different experience levels delineated fascicles twice, using static and dynamic US images. Delineations were compared with high-field MRI. The influence of probe frequency was evaluated on 12 median nerves of healthy volunteers. Median nerves at wrist were scanned using 14-, 18-, 24-, and 70-MHz US probes. Images were cross-referenced, and fascicle counts were compared relative to the highest-frequency probe.
Results
Dynamic imaging improved fascicle differentiation by 27.6% to 51.2% compared to static (P < .001), with a greater benefit for less experienced evaluators. The most experienced evaluator identified on average 62.3% more fascicles in dynamic assessment compared to the least experienced. The 70-MHz probe showed the highest mean fascicle count (27.6 ± 3.7), while 24-, 18-, and 14-MHz probes differentiated 26%, 46%, and 63% fewer fascicles, respectively (P <. 0001).
Conclusions
Fascicle differentiation improves significantly with evaluator experience, using dynamic US image interpretation, and higher probe frequency. These findings support the clinical utility of ultrahigh-frequency US for detailed evaluation of superficial nerves.
Clinical relevance
Experience and dynamic image interpretation are important for reliable fascicle recognition and to minimize misinterpretation. Ultrahigh-frequency US probes substantially improve fascicle differentiation, but their limited penetration requires careful selection of probe frequency based on nerve depth.
期刊介绍:
The Journal of Hand Surgery publishes original, peer-reviewed articles related to the pathophysiology, diagnosis, and treatment of diseases and conditions of the upper extremity; these include both clinical and basic science studies, along with case reports. Special features include Review Articles (including Current Concepts and The Hand Surgery Landscape), Reviews of Books and Media, and Letters to the Editor.